mxion MAD Micron Dynamics User Manual
- June 3, 2024
- mXion
Table of Contents
- mxion MAD Micron Dynamics
- Introduction
- General information
- Summary of Functions
- Scope of supply
- Hook-Up
- Connectors
- Product description
- Programming lock
- Reset functions
- CV-Table
- Technical data
- Warranty, Service, Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
mxion MAD Micron Dynamics
Introduction
Dear customer, we strongly recommend that you read these manuals and the
warning notes thoroughly before installing and operating your device. The
device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before
hooking up any other device. We can’t be responsible For any damage if this is
disregarded.
General information
We recommend studying this manual thoroughly before installing and operating
your new device.
NOTE: Some functions are only available with the latest firmware. Please
make sure that your device is programmed with the latest firmware.
Summary of Functions
- DCC NMRA digital operation
- Compatible NMRA-DCC module
- Märklin-Motorola digital operation
- Very small outlet
- 6 reinforced function output
- 3 Switch output (double coil switches) Outputs invertible
- Automatic switch back functions
- Switch outputs dimmable
- Reset function for all CV values
- Easy function mapping
- Programming via programming switch Multiple programming options
- (Bitwise, CV, POM accessories decoder, register) Needs no programming load
Reach of wireless depends on house WLan
Scope of supply
- Manual
- mXion MAD
Hook-Up
Install your device in compliance with the connecting diagrams in this manual.
The device is protected against shorts and excessive loads. However, in case
of a connection error e.g. a short this safety feature can’t work and the
device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or
metal.
Connectors
-
DCC/MM switch
At operation, programming switch, change direction for start programming to send desired address to switch back to normal state -
DCC/MM switch
At operation, programming switch, change direction for start programming to send desired address to switch back to normal state
Product description
The mXion MAD is a very small but powerful 3 Ch. turnout decoder for double
coil switches and ideal for use all tracks where these drivers are used.
He offers various programmable functions like dimming, duration of switching
(also permanently for e.g. illuminations as well an automatic downshift
function after time (e.g. fallback).
The 3 turnout addresses can be independently program and do not need each
other be following. In addition to the usual CV programming also supports the
module a programming switch to quickly get the addresses to be able to change.
The module supports DCC and Motorola, so this decoder can be used universally.
Programming lock
To prevent accidental programming to prevent CV 15/16 one programming lock.
Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes
automatically also CV 15. With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 165
Programming options
This decoder supports the following programming types: bitwise, POM and CV
read & write and register-mode and programming switch.
There will be no extra load for programming.
In POM (programming on main track) the programming lock is also supported. The
decoder can also be on the main track programmed without the other decoder to
be influenced. Thus, when programming the decoder can not be removed.
NOTE: To use POM without others decoder must affect your digital center
POM to specific decoder addresses (e.g. Massoth® control panels)
Programming binary values
Some CV’s (e.g. 29) consist of so-called binary values. The means that several
settings in a value. Each function has a bit position and a value. For
programming such a CV must have all the significances can be added. A disabled
function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you
must set the value in CV 29 2 + 32 = 34 programmed.
Programming switch adress
Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in address low. The high address
is 0. If the address is > 255 this is as follows (for example address 2000):
- 2000 / 256 = 7,81, address high is 7
- 2000 – (7 x 256) = 208, address low is then 208.
About the programming button:
Change the position of the slider during operation, the point output 1 will
alternate in 1 sec. clocking.
Switch on the desired control unit on the control unit switch address, then
output 1 will alternate faster (0,5 sec). In order to the address has been
accepted correctly and all 3 outputs are numbered.
You can now put the slider back on the switch the original state. The protocol
can not be changed during operation become!
Reset functions
The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values:
- 11 (basic functions)
- 16 (programming lock CV 15/16)
- 33 (switch outputs)
CV-Table
S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable
CV | Description | S | L/S | Range | Note |
---|---|---|---|---|---|
7 | Software version | – | – | read only (10 = 1.1) | |
7 | Decoder reset functions | ||||
3 ranges available | 11 |
16
33| basic settings (CV 1,11-13,17-19,29-119) programming lock (CV 15/16)
function- & Switch outputs (CV 120-139)
8| Manufacturer ID| 160| | –| read only
7+8| Register programming mode
Reg8 = CV-Address Reg7 = CV-Value| | | | CV 7/8 don’t changes his real value
CV 8 write first with cv-number, then CV 7 write with value or read (e.g.: CV
49 should have 3)
è CV 8 = 49, CV 7 = 3 writing
15| Programming lock (key)| 165| S| 0 – 255| to lock only change this value
16| Programming lock (lock)| 165| S| 0 – 255| changes in CV 16 will change CV
15
18| Switch address calculation| 0| S| 0/1| 0 = Switch address like norm
1 = Switch address like Roco, Fleischmann
19| mXion configuration| 0| S| | bitwise programming
Bit| Value| OFF (Value 0)| ON
0| 1| Switch 1 normal output| Switch 1 inverted output
1| 2| Switch 2 normal output| Switch 2 inverted output
2| 4| Switch 3 normal output| Switch 3 inverted output
20| switch address 1 high| 0| S| 1 – 2048| switch output 1, if address smaller
256 easy program CV21 = desired address!
---|---|---|---|---|---
21| switch address 1 low| 1| S
22| switch 1 dimming value| 100| S| 1 – 100| dimming value in % (1 % approx.
0,2 V)
23| switch 1 time for automatic switch back function| 0| S| 0 – 255| 0 = off
1 – 255 = time base 0,25 sec. each value
24| switch 1 switch off time| 5| S| 0 – 255| 0 = permanent on
1 – 255 = time base 0,25 sec. each value
25| switch address 2 high| 0| S| 1 – 2048| switch output 2, if address smaller
256 easy program CV26 = desired address!
26| switch address 2 low| 2| S|
27| switch 2 dimming value| 100| S| 1 – 100
0 – 255| dimming value in % (1 % approx. 0,2 V)
0 = off
28| switch 2 time for automatic switch back function| 0| S| | 1 – 255 = time
base 0,25 sec. each value
29| switch 2 switch off time| 5| S| 0 – 255| 0 = permanent on
1 – 255 = time base 0,25 sec. each value
30| switch address 3 high| 0| S| 1 – 2048| switch output 3, if address smaller
256 easy program CV31 = desired address!
31| switch address 3 low| 3| S
32| switch 3 dimming value| 100| S| 1 – 100| dimming value in % (1 % approx.
0,2 V)
33| switch 3 time for automatic switch back function| 0| S| 0 – 255| 0 = off
1 – 255 = time base 0,25 sec. each value
34| switch 3 switch off time| 5| S| 0 – 255| 0 = permanent on
1 – 255 = time base 0,25 sec. each value
Technical data
-
Power supply: 7-27V DC/DCC
5-18V AC -
Current: 5mA (with out functions)
-
Maximum function current:
- Switch 1 0.5 Amps.
- Switch 2 0.5 Amps.
- Switch 3 0.5 Amps.
-
Maximum current: 1.5 Amps.
-
Temperature range: -40 up to 85°C
-
Dimensions LBH (cm): 2.52.71
NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.
Warranty, Service, Support
micron-dynamics warrants this product against defects in materials and
workmanship for one year from the original date of purchase. Other countries
might have different legal warranty situations. Normal wear and tear, consumer
modifications as well as improper use or installation are not covered.
Peripheral component damage is not covered by this warranty. Valid warrants
claims will be serviced without charge within the warranty period. For
warranty service please return the product to the manufacturer. Return
shipping charges are not covered by micron-dynamics. Please include your proof
of purchase with the returned good. Please check our website for up to date
brochures, product information, documentation and software updates. Software
updates you can do with our updater or you can send us the product, we update
for you free.
Errors and changes excepted.
Hotline
For technical support and schematics for application examples contact:
micron-dynamics
info@micron-dynamics.de
service@micron-dynamics.de
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>