Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thouroughly before installing and operating your device. The device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device. Place the decoder in a protected location. The unit must not be exposed to moisture.
NOTE: Some funktions are only available with the latest firmware. Please make sure that your device is programmed with the latest firmware.

Summary of Functions

DCC NMRA digital operation Very small outlet
Compatible NMRA-DCC module 2 reinforced function outputs
2 inputs
2 independed servo outputs All times configurable
Re-Swing function
Audio output 3W for bell sounds 4 Sounds available

  • DB (electrical)
  • SBB/RhB (electrical)
  • USA (electrical)
  • DR (mechanical) also fits DB, HSB Railcrossing control unit

Defined start switching position Outputs invertable Freq. adjustable for Hall- effect for DR bell Double bell for DR-bell sound Function outputs dimmable Reset function for all CV values Easy function mapping Multiple programming options (Bitwise, CV, POM accessoire decoder, register) Needs no programming load.

Scope of supply

  • Manual
  • mXion KBM

Hook-Up

Install your device in compliance with the connecting diagrams in this manual. The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.
NOTE: Please note the CV basic settings in the delivery state.

Connectors

The opposite pole (DEC+) is on the bottom as a soldering contact. This is the opposite pole for the outputs A1 and A2. The opposite pole for the switching contacts K1 and K2 is DEC- (GND). This one is also on the bottom. Alternatively, K1 and K2 can also be used against the digital track.

mXion-KBM-Railway-Barrier-Module-1

Product description

The mXion KBM is a universal usable railroad crossings module. The module stands out especially because of its many adjustment options out. In addition to 2 servo connection operable) hast he module 2 switching outputs for St. andrew’s cross lights. with up to 1 A per output as well as 2 switching inputs for manual triggering and an audio output as well as 4 stored gong sounds of the most common railroad crossings. A connection for one volume control is also available, alternatively but this can also be done by programming. The module is characterized by the fact that one all times such as the waiting time before the drop
the barriers, yes even one offset of the barriers, yes even one offset of the barriers flashing and gonglength as well as many other settings ca. As a special feature, it is even possible to adjustable rocker length and speed. Another feature is the same changing the gong-off time so that you can choose the gong and the flashing the outputs even when closed barrier (e.g. USA) can use. This feature also allows the use on unrestricted level crossings.

Connecting example analog
In analog mode, the module is bel. tension supplied and the control fo the barriers takes place through the 2 contact inputs. These can also, for example, parallel to a commercial button in the track with a reed.

Connecting example digital
The contact inputs are only necessary if the module should see the train and switch automatically. Optionally Reed or light barriers.

mXion-KBM-Railway-Barrier-Module-3

Programming lock

To prevent accidental programming to prevent CV 15/16 one programming lock. Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes automatically also CV 15. With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 115

Programming options
This decoder supports the following programming types: bitwise, POM and CV read & write and register-mode.
There will be no extra load for programming.
In POM (programming on maintrack) the programming lock is also supported. The decoder can also be on the main track programmed without the other decoder to be influenced. Thus, when programming the decoder can not be removed.
NOTE: To use POM without others decoder must affect your digital center POM to specific decoder adresses.

Programming binary values
Some CV’s (e.g. 29) consist of so-called binary values. The means that several settings in a value. Each function has a bit position and a value. For programming such a CV must have all the significances can be added. A disabled function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you must set the value in CV 29 2 + 32 = 34 programmed.

Programming switch address
Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in the address low. The high address is 0. If the address is > 255 this is as follows (for example address 2000):
2000 / 256 = 7,81, address high is 7
2000 – (7 x 256) = 208, address low is then 208.
Programm these values into the CVs of manual driving of turn.

Reset functions

The decoder can be reset via CV 7. Various areas can be used for this purpose. Write with the following values:

  • 11 (basic functions)
  • 16 (programming lock CV 15/16)
  • 33 (function and switch outputs)

CV-Tabelle

S = Standard, A = Analogbetrieb nutzbar

S = Standard, A = Analogbetrieb nutzbar

mXion-KBM-Railway-Barrier-Module-5

S = Default, A = Analog operation usable

S = Default, A = Analog operation usable

mXion-KBM-Railway-Barrier-Module-7

Technical data

  • Power supply: 7-27V DC/DCC 5-18V AC
  • Current: 10mA (with out functions)
  • Maximum function current:
    • A1 0.5 Amps.
    • A2 0.5 Amps.
  • Maximum sound power: 3 Watts
  • Maximum current: 3A Amps.
  • Temperature range: -20 up to 85°C
  • Dimensions LBH (cm): 3.24.23.0

NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of  condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered. Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free. Errors and changes excepted.

Hotline
For technical support and schematics for application examples contact: micron- dynamics
[email protected]
[email protected]

www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals