mXion LSS-DKW Turnout Lantern User Manual

June 3, 2024
mXion

mXion LSS-DKW Turnout Lantern

mXion-LSS-DKW-Turnout-Lantern-product

Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thouroughly before installing and operating your device. The device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device. Place the decoder in a protected location. The unit must not be exposed to moisture.
NOTE: Some funktions are only available with the latest firmware. Please make sure that your device is programmed with the latest firmware.

Summary of Funktions

  • DC/AC/DCC operation
  • Compatible NMRA-DCC module
  • Real light signals
  • Defined start switching
  • Outputs invertable
  • Automatic switch back functions
  • Function outputs dimmable
  • Reset function for all CV values
  • Easy function mapping adresses, 2048 switch adresses
  • Multiple programming options (Bitwise, CV, POM accessoire decoder, register) Needs no programming load

Scope of supply

  • Manual
  • mXion LSS-DKW

Hook-Up

Install your device in compliance with the connecting diagrams in this manual. The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently. Make sure that there is no short circuit caused by the mounting screws or metal.
NOTE: Please note the CV basic settings in the delivery state.

Product description

The mXion LSS-DKW is a switch latern for double crossing points (DKW). These laterns can be found on all DKWs around their current direction and position of the switch tongues display. The systematic structure of the turnout addresses for control can switch latern to the switching behavior of the turnout can be adjusted (e.g. by inversion). You can also set whether the transitions the switching states are blinded or pure should be switched. The brightness leaves also change.
The module only works digital! At outdoor use glue the housing tightly, it is also recommended to use the circuit board seal with Plastik70®.

Programming lock
To prevent accidental programming to prevent CV 15/16 one programming lock. Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes automatically also CV 15. With CV 7 = 16 can the programming lock reset.

STANDARD VALUE CV 15/16 = 215
Programming options

  • This decoder supports the following programming types: bitwise, POM and CV read & write and register-mode.
  • There will be no extra load for programming.
  • In POM (programming on maintrack) the programming lock is also supported. The decoder can also be on the main track programmed without the other decoder to be influenced. Thus, when programming the decoder can not be removed.
    NOTE: To use POM without others decoder must affect your digital center POM to specific decoder adresses

Programming binary values
Some CV’s (e.g. 29) consist of so-called binary values. The means that several settings in a value. Each function has a bit position and a value. For programming such a CV must have all the significances can be added. A disabled function has always the value 0.

EXAMPLE: You want 28 drive steps and long loco address. To do this, you must set the value in CV 29 2 + 32 = 34 programmed.

Programming switch adress
Switch addresses consist of 2 values. For addresses < 256 the value can be directly in address low. The high address is 0. If the address is > 255 this is as follows (for example address 2000):

  • 2000 / 256 = 7,81, address high is 7
  • 2000 – (7 x 256) = 208, address low is then 208.

Programm these values into the SW1, SW2, and so on CVs.

Reset functions

The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values:

  • 11 (basic functions)
  • 16 (programming lock CV 15/16)
  • 33 (switch outputs)

CV-Table

S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable

CV Description S L/S Range Note
7 Software version   read only (10 = 1.1)
7 Decoder reset functions

3 ranges available

|  |  | 11

16

33

| basic settings (CV 1,11-13,17-19,29-119) programming lock (CV 15/16)

switch outputs (from CV 120)

8| Manufacturer ID| 160|  | –| read only
7+8| Register programming mode

Reg8 = CV-Address Reg7 = CV-Value

|  |  |  | CV 7/8 don’t changes his real value

CV 8 write first with cv-number, then CV 7 write with value or read

(e.g.: CV 49 should have 3)

è CV 8 = 49, CV 7 = 3 writing

15| Programming lock (key)| 215| LS| 0 – 255| to lock only change this value
16| Programming lock (lock)| 215| LS| 0 – 255| changes in CV 16 will change CV 15
48| Switch address calculation| 0| S| 0/1| 0 = Switch adress like norm

1 = Switch adress like Roco, Fleischmann

49| mXion configuration| 66| S|  | bitwise programming
Bit| Value| OFF (Value 0)| ON
0| 1| Right normal output| Right inverted
1| 2| Transition normal switching| Transition fading
2| 4| Transition same time fading| Transition after ones fading
4| 16| Left normal output| Left inverted
6| 64| do not save switch position| save switch position
120| Right address high| 0| S| 1 – 2048| switch signalstate, if address smaller 256 easy programm CV121 = desired address!
121| Right address low| 1| S
122| Left address high| 0| S| 1 – 2048| switch signalstate, if address smaller 256 easy programm CV123 = desired address!
123| Left address low| 2| S
124| Dimming value| 20| S| 1 – 100| dimming value in % (1 % approx. 0,2 V)
125| Automatic switch back function to last state| 0| S| 0 – 255| 0 = off

1 – 255 = time base 0,25 sec. each Value

Technical data

  • Power supply:
    7-27V DC/DCC
    5-18V AC

  • Current: 5mA (with out functions)

  • Maximum function current: LSS 0.1 Amps.

  • Maximum current: 1 Amps.

  • Temperature range: – 20 up to 85°C

  • Dimensions LBH (cm): DKW-Signal 335

NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered. Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free. Errors and changes excepted.

Hotline
For technical support and schematics for application examples contact: micron- dynamics
info@micron-dynamics.de service@micron- dynamics.de
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals