mXion LSS-WSD Turnout Lantern User Manual

June 3, 2024
mXion

mXion LSS-WSD Turnout Lantern

mXion LSS-WSD Turnout Lantern product

Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thouroughly before installing and operating your device. The device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device.
Place the decoder in a protected location. The unit must not be exposed to moisture.
NOTE: Some funktions are only
available with the latest firmware. Please make sure that your device is programmed with the latest firmware.

Summary of Functions

  • DC/AC/DCC operation
  • Compatible NMRA-DCC module
  • Real light signals
  • Defined start switching
  • Outputs invertable
  • Automatic switch back functions
  • Function outputs dimmable
  • Reset function for all CV values
  • Easy function mapping
  • addresses, 2048 switch addresses
  • Multiple programming options
  • (Bitwise, CV, POM accessory decoder, register) Needs no programming load

Scope of supply

  • Manual
  • mXion LSS-WSD

Hook-Up

Install your device in compliance with the connecting diagrams in this manual. The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.
NOTE: Please note the CV basic settings in the delivery state.

Connectors

This typical switch signal is for everyone train company. It can due to the small dimensions optimally in the station area be accommodated. The signal works digitally as well as analog. Simply close the 2 cables to the track or a DC voltage source e.g. EPL®.
The signal has on both sides LEDs Weather proof: Cover the PCB with „Plastik70“.

mXion LSS-WSD Turnout Lantern fig 1

Product description

The mXion LSS-WSD is a modern light signal for switches. These signals show with clear pictures setting the course for the train driver. The LSS-WSD supports all images as well as the rear shutdown when closed soft This function can be deactivated via CV. The switching time and flashing frequency can vary according to be customized and is ideal adjustable for our slow switching point machines SWD, PLUG, DWA and MWB.
The integrated decoder for analog and digital operation allows all images of the signal to be given in an exemplary way. In addition will be a series of switching and additional functions allows, which are separately activated (e.g. automatic switching back to timing when a train has passed).

Programming lock

To prevent accidental programming to prevent CV 15/16 one programming lock. Only if CV 15 = CV 16 is a programming possible. Changing CV 16 changes automatically also CV 15.
With CV 7 = 16 can the programming lock reset.
STANDARD VALUE CV 15/16 = 215

Programming options

This decoder supports the following programming types: bitwise, POM and CV read & write and register-mode.
There will be no extra load for programming. In POM (programming on maintrack) the programming lock is also supported. The decoder can also be on the main track programmed without the other decoder to be influenced. Thus, when programming the decoder can not be removed.

NOTE: To use POM without others decoder must affect your digital center POM to specific decoder adresses

Programming binary values

Some CV’s (e.g. 29) consist of so-called binary values. The means that several settings in a value. Each function has a bit position and a value. For programming such a CV must have all the significances can be added. A disabled function has always the value 0.
EXAMPLE: You want 28 drive steps and long loco address. To do this, you must set the value in CV 29 2 + 32 = 34 programmed.

Programming switch address

Switch addresses consist of 2 values.
For addresses < 256 the value can be directly in address low. The high address is 0. If the address is > 255 this is as
follows (for example address 2000):

  • 2000 / 256 = 7,81, address high is 7
  • 2000 – (7 x 256) = 208, address low is then 208.

Programme these values into the SW1, SW2, and so on CVs.

Reset functions

The decoder can be reset via CV 7. Various areas can be used for this purpose.
Write with the following values:

  • 11 (basic functions)
  • 16 (programming lock CV 15/16)
  • 33 (switch outputs)

CV-Table

S = Default, L = Loco address, S = Switch address, LS = Loco and switch address usable

CV| Description| S| L/S| Range| Note|
---|---|---|---|---|---|---
7| Software version| –| | –| read only (10 = 1.1)|
7| Decoder reset functions|

3 ranges available

| | | 11

16

33

| basic settings (CV 1,11-13,17-19,29-119) programming lock (CV 15/16)

switch outputs (from CV 120)

|
8| Manufacturer ID| 160| | –| read only|
7+8| Register programming mode|

Reg8 = CV-Address Reg7 = CV-Value

| | | | CV 7/8 don’t changes his real value

CV 8 write first with cv-number, then CV 7 write with value or read

(e.g.: CV 49 should have 3)

è CV 8 = 49, CV 7 = 3 writing

|
15| Programming lock (key)| 215| LS| 0 – 255| to lock only change this value|
16| Programming lock (lock)| 215| LS| 0 – 255| changes in CV 16 will change CV 15|
48| Switch address calculation| 0| S| 0/1| 0 = Switch adress like norm

1 = Switch adress like Roco, Fleischmann

|
49| mXion configuration| 6| S| | bitwise programming
Bit| Value| OFF (Value 0)| ON
0| 1| SW1 normal output| SW1 inverted
1| 2| SW1 normal function| SW1 defined position
2| 4| defined position normal| defined position invers
3| 8| back light normal| back light always on
118| Automatic switch back function to last state| 0| S| 0 – 255| 0 = off

1 – 255 = time base 0,25 sec. each Value

120| SW1 address high| 0| S| 1 – 2048| switch signal state, if address smaller 256 easy programm CV121 = desired address!
121| SW1 address low| 1| S
122| dimming value| 100| S| 1 – 100| dimming value in % (1 % approx. 0,2 V)
124| flashing frequency| 5| W| 1 – 255| time base 0,1 sec/value
125| flip over time| 50| W| 1 – 255| time base 0,1 sec/value

Technical data

  • Power supply: 7-27V DC/DCC, 5-18V AC
  • Current: 5mA (with out functions)
  • Maximum function current
    • LSS: 0.1 Amps.
  • Maximum current: 1 Amps.
  • Temperature range: -20 up to 85°C
  • Dimensions LBH (cm): WSD-Signal 335

NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered. Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free. Errors and changes excepted.

Hotline
For technical support and schematics for application examples contact:
micron-dynamics
[email protected]
[email protected]

www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>