Introduction

Dear customer, we strongly recommend that you read these manuals and the warning notes thouroughly before installing and operating your device. The device is not a toy (15+).
NOTE: Make sure that the outputs are set to appropriate value before hooking up any other device. We can’t be responsible For any damage if this is disregarded.

General information

We recommend studying this manual thoroughly before installing and operating your new device.
Place the decoder in a protected location.
The unit must not be exposed to moisture.
NOTE: Some funktions are only available with the latest firmware.
Please make sure that your device is programmed with the latest firmware.

Summary of Funktions

DC/AC/DCC/PWM/ANALOG operation 5-Channel functionmode Light imitation for funfair e.g.
Robust, simple screw clamp

Scope of supply

Manual
mXion KLM

Hook-Up

Install your device in compliance with the connecting diagrams in this manual.
The device is protected against shorts and excessive loads. However, in case of a connection error e.g. a short this safety feature can’t work and the device will be destroyed subsequently.
Make sure that there is no short circuit caused by the mounting screws or metal.

Connectors

Switch consumption between A1-5 and +.
By connecting K1 and –can the associated output be switched.
The – pole is on the bottom side!

Product description

The mXion KLM is a versatile module.
This module implements five output channels of a fair module. You can for example 5 buildings with 5 different lights and this light or at the fair the action in different patterns light up.
Simply connect each building or a string of lights on to CH1-CH4. The common pole is the positive pole. The modes include running lights, strobe and fader. All channels (1-5) are each illuminated different and alternately to a colorful and effective as possible to implement lighting.

Since many light games are sequential is recommended that you, your bulbs, LEDs, or other in the following ordert o the module connect:

LED1 LED2 LED3 LED4 LED5
CH1 CH2 CH3 CH4 CH5

Technical data

Power supply: 7-27V DC/DCC/PWM
5-20V AC
Current: 1mA (with out functions)
Maximum function current: Channel 1 – 4: 1 Amps
Channel 5: 0.1 Amps
Max. output from module: 2 Amps
Temperature range: -5 up to 50°C
Dimensions LBH (cm): 2.72.31

NOTE: In case you intend to utilize this device below freezing temperatures, make sure it was stored in a heated environment before operation to prevent the generation of condensed water. During operation is sufficient to prevent condensed water.

Warranty, Service, Support

micron-dynamics warrants this product against defects in materials and workmanship for one year from the original date of purchase. Other countries might have different legal warranty situations. Normal wear and tear, consumer modifications as well as improper use or installation are not covered.
Peripheral component damage is not covered by this warranty. Valid warrants claims will be serviced without charge within the warranty period. For warranty service please return the product to the manufacturer. Return shipping charges are not covered by micron-dynamics. Please include your proof of purchase with the returned good. Please check our website for up to date brochures, product information, documentation and software updates. Software updates you can do with our updater or you can send us the product, we update for you free.
Errors and changes excepted.

Hotline

For technical support and schematics for application examples contact:
micron-dynamics
info@micron-dynamics.de
service@micron-dynamics.de
www.micron-dynamics.de
https://www.youtube.com/@micron-dynamics

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals