85 057
Technical amendments reserved
Garden and pathway luminaire with PIR motion and light sensor
Project
Location
Data Matrix
Code
Instructions for use
Application
Unshielded garden and path luminaire with safety guard. Light exit 180°.
With hand-blown, three-ply opal glass and pleasantly uniform light effect for
effective illumination in private gardens.
The integrated passive infrared motion and light sensor responds to heat
emission in the dark and activates in case of human or animal movement in the
vicinity of the luminaire.
Configuration is done via Bluetooth using smartphone or tablet and the free
BEGA Smart app.
Lamp|
---|---
Module connected wattage| 3.9 W
Luminaire connected wattage| 5.4 W
Rated temperature| ta = 25 °C
Ambient temperature| tamax = 45 °C
85 057 K3|
Module designation| LED-0794/830
Colour temperature| 3000 K
Colour rendering index| CRI > 80
Module luminous flux| 750 lm
Luminaire luminous flux| 99 lm
Luminaire luminous efficiency| 18,3 lm / W
85 057 K4|
Module designation| LED-0794/840
Colour temperature| 4000 K
Colour rendering index| CRI > 80
Module luminous flux| 770 lm
Luminaire luminous flux| 101 lm
Luminaire luminous efficiency| 18,7 lm / W
Lighting technology
Recommended light point interval 4.5 m
Product description
Luminaire made of cast aluminium, aluminium and stainless steel BEGA Unidure®
coating technology Colour graphite or silver Opal glass with screw neck
Silicone gasket
Luminaire with mounting base made of hot-dip galvanised steel according to EN
ISO 1461 for bolting onto a foundation provided by the customer or on other
paved surfaces such as terraces and paving stones
Base plate with 3 fixing holes ø 9 mm · Pitch 120° · Pitch circle ø 65 mm
Mounting bracket with connection box for through-wiring of up to 3 x 2,5 mm²
Passive infrared motion sensor (PIR) Range up to 12 m Opening angle 120°–150°
Decals for reducing the detection range are provided
Minimum temperature difference between moving object and environment 4 °C
Object speed ideally 1 m/s
Adjustable sensitivity of the motion sensor (inertia) Shut-down delay
adjustable between 5 s and 240 min
Light sensor: adjustable value range from darkness (ca. 0 lx) to approaching
dusk (approx. 150 lx)
Fixed pre-set hysteresis for suppression of undesired switching operations in
luminaires during rapid brightness fluctuations
Transmission frequency range: 2400-2483.5 MHz
Maximum transmission output: 10 mW
Luminaire switchable via relay output (on/off) integrated in the sensor module
Relay contact with a switching capacity of 2300 W · 10 A
Please note the starting current of the switching loads – max. 100 A
Ambient temperature: -25°C to +55°C
Luminaire power supply unit
Starting current: 7 A (112 µs)
220-240 V 50-60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK04
Protection against mechanical impacts < 0.5 joule
– Conformity mark
This product contains light sources of energy efficiency class(es) C
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
The base of the luminaire must not be below top edge of the ground surface.
A cable length of 400 mm above the ground surface is required for the
electrical connection of the luminaire.
Remove the mounting base from the luminaire by undoing the screws at the base
of the luminaire.
Lead underground cable from below in the mounting base.
Fix the mounting base with enclosed or any other suitable fixing material onto
the mounting surface.
Open the connection box.
Lead the luminaire wiring and mains supply cable into the connection box.
Make the earth conductor connection and the electrical connection.
Note the correct configuration of the terminals (see drawing).
Close the connection box.
Lead the bollard tube on the anchorage unit and align.
Tighten the screws evenly.
Screw the glass with the gasket into the luminaire housing and tighten firmly.
Make sure that the glass gasket is seated correctly (see sketch).
Commissioning
The power supply must be connected for the commissioning of the luminaire.
The brightness sensor will need up to 10 minutes after activation of the power
supply to correctly calibrate the brightness value.
Once installed, the luminaire can be operated immediately in its factory
settings; configuration via smartphone will not be required.
The factory settings as are follows:
Mode: Motion and light
Motion sensitivity: 100 % (high sensitivity)
Shut-down delay: 5 minutes
Brightness threshold: 32 (approx. 50 lx)
Alternatively, the integrated PIR motion and light sensor can be configured
via smartphone or tablet using the free BEGA Smart app.
The default values can be reinstated at any time via the BEGA Smart app.
bega.com/bega-smart-ios
bega.com/bega-smart-android
Download the app for Android or iOS and add the luminaire as your starting
point.
The Data matrix code needed for commissioning is provided on the sensor
housing, the luminaire head and on the connecting cable of the luminaire.
Please retain the additional enclosed QR codes in your customer documentation
(e.g. Instructions for use, at the top of Page 1).
Select the “Share access” function in the BEGA Tool app enables
parameterisation or control via additional smartphones. function in the BEGA
Tool app if you want to use a different or additional smartphone for the
configuration of the integrated sensor module or controlling the luminaire
head.
Please note:
The integrated light sensor operates with a time delay to prevent responses to
short-term brightness fluctuations in the environment of the luminaire. Delay
time approx. 1 to 3 min. A manual darkening of the sensor will therefore not
result in an immediate response.
Once successfully commissioned, the sensor can be configured in the BEGA Smart
app.
The following 3 states can be set:
- “Illumination during movement”
– State that is activated for the configured shut-down delay period when movement is detected.
If the light sensor is also active, motion detection is only activated if the
light sensor detects the environmental brightness to be below the configured
threshold.
After the shut-down delay period, the state “Illumination at specific
environmental brightness” is executed.
If the light sensor is deactivated, the state is activated independently of
the environmental brightness if movement is detected.
After the configured shut-down delay period, “Illumination in default state”
is activated.
-
“Illumination at specific environmental brightness”
– State which is activated when the environmental brightness falls below the configured threshold. -
“Illumination in default state”
– State which is activated when the environmental brightness has exceeded the configured threshold value and no movement is detected.
The motion sensor as well as the light sensor can be switched off
individually. This reduces the respective states.
The shut-down delay is freely adjustable up to 4 hours.
The current measured environmental brightness can be queried. This is shown by
the grey sun symbol. The threshold value can also be set there.
All other components in the BEGA Smart System can be allocated and configured
to these states. Depending on the additionally used BEGA Smart components,
different light levels, light colours or colour temperatures can be set.
The luminaire head of the bollard can only be switched on or off.
Range / Detection area
The specifications for the range and detection area of the PIR motion sensor
are reference values. Detection range is 120° to 150° at a depth of 5 m up to
max. 12 m, depending on motion direction (see illustration).
Too minor temperature difference between the moving object and the ambient
temperature can influence the detection range.
Local conditions and external heat sources may affect both the range and the
detection area.
Reducing the detection range
Use the decals provided to reduce the vertical detection area of the sensor.
The smaller decals reduce the detection area by around one third, the larger
ones by around one half (see sketch). Clean the sensor with a soft cloth
soaked in alcohol before applying the decals. Ensure exact positioning when
attaching the decals.
Circuit variants
Forwarding of the switching signal to additional luminaires can be achieved
via the relay contact L’ (see circuit diagram 1).
Circuit diagram 1:
The first sensor of a luminaire controls a group of luminaires, while the
second luminaire sensor controls another group.
Circuit diagram 2:
Sensors of multiple luminaires control the same luminaire group.
All luminaires in the group will be switched on as soon as one of the sensors
detects movement.
It is important to note that all sensors within one group are fed via the same
phase.
Circuit diagram 3:
Apart from wired control, the sensor also offers the option of wireless
communication with Zigbee lamps or other BEGA Smart actuators, e.g. 71149
Reset to factory settings
The luminaire must be switched off five times within 30 seconds for at least 2
seconds each time to manually reset it to factory settings (see sketch).
The luminaire can furthermore be reset to the factory settings via the BEGA
Smart app.
The reset is confirmed with five flashes of the luminaire.
The smartphone will be disconnected.
Status display
Status LED flashes green:
The luminaire is searching for a nearby network and is ready for
configuration.
If no start-up procedure is executed within 180 seconds, the status LED goes
out.
Status LED flashes green and the luminaire is already configured:
The luminaire opens the network for new participants in the BEGA Smart System.
EU Declaration of Conformity
BEGA Gantenbrink-Leuchten KG hereby declares that the radio system type 85 057
complies with Directive 2014/53/EU (RED).
The complete text of the EU Declaration of Conformity is available at the
following Internet address: https://www.bega.com/conf/de/85057
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Spare glass
LED power supply unit
LED module 3000 K
LED module 4000 K
PIR and light sensor graphite
PIR and light sensor silver
Gasket glass| 11 003 514 .1
DEV-0303/350
LED-0794/830
LED-0794/840
75 005 857
75 005 859
83 001 998
---|---
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>