LUMINO Vero-S IP67 20x20mm Linear Lighting Instruction Manual
- June 24, 2024
- LUMINO
Table of Contents
- LUMINO Vero-S IP67 20x20mm Linear Lighting Instruction Manual
- Specifications
- HANDLING PRECAUTIONS
- SAFETY GUIDANCE
- ACCESSORIES
- CHECK FIRST
- INSTALLATION
- Mounting Clips
- Connect to LED Driver
- Mount Product
- Protect exposed cable
- EASY MOUNT INSTALLATION
- ROTATION MOUNT INSTALLATION
- EMERGENCY CHARGING LED
- INSTALLATION
- ECODESIGN REGULATION
- DISMANTLING
- ENERGY RATING
- FAQ
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
LUMINO Vero-S IP67 20x20mm Linear Lighting Instruction Manual
Specifications
- Model: Vero-S IP67
- Rating: IP67
- IK Rating: IK08
- Output: 24VDC SELV Product Usage Instructions
Handling Precautions
Ensure small or sharp objects do not apply pressure to the plastic cover/diffuser. Avoid placing weighted items on the product. Do not pull or twist power cables and connectors. Do not modify the product in any way.
Location
Suitable for wet locations, rated for temporary submersion. Provide adequate drainage and protect from dust, paint, and harmful substances. Avoid exposure to VOC gases and ensure no obstruction to light output.
Wiring Guide
Follow the provided wiring guide for cable lengths, sizes, and other instructions. Protect cables from damage, separate them from mains voltage cables, and anchor them against being pulled. Make connections appropriate for the IP rating.
Qualified Installer
Installation must be done by a qualified person following local regulations. Provide clear air space for LED drivers and follow installation instructions.
Repair and Replacement
Contact LUMINO for factory repair or replacement if the product is not functioning. The light source is not user-replaceable.
Power Off
Ensure product and driver are not live-wired. Switch off the power before work. Follow specific instructions for the driver model being used.
Dimmers
Check dimmer compatibility with the driver and local regulations.
Inrush Current
Use suitable MCB for high inrush current at power-on. Type C MCBs are generally suitable; consider using an inrush suppressor if needed.
HANDLING PRECAUTIONS
-
PLASTIC COVER / DIFFUSER
To avoid permanent damage, do not allow small or sharp objects to apply pressure on to the plastic cover / diffuser. -
IMPACT PROTECTION
The product is not vandal resistant. Never stand or place weighted items on the product. This product has a maximum IK rating of IK08. -
POWER CABLES
The product end caps, power cables and connectors must not be pulled or twisted. Never pull the product by its power cables or hang it from its power cables or connectors. -
CUTTING AND SAWING
The product must not be sawn, drilled or otherwise modified in any way. -
DAMAGES
Inspect the product. If you see any damage upon unpacking, report to LUMINO immediately and do not install the product. -
LOCATION
Suitable for wet locations. IP67 rated for temporary submersion for no more than 30mins. Ensure there is adequate drainage made available for the product.
Protect product from dust, paint and harmful substances during installation and use.
Ensure product is not exposed to VOC gases. Do not obstruct the product and its light output.
SAFETY GUIDANCE
-
WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum cable lengths, cable sizes and other wiring instructions. When running cables through an enclosure, ensure cables are protected from damage, separated from mains voltage cables and anchored against being pulled. Make connections appropriate for the IP rating of the product. -
QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted by local regulations and applicable standards. -
THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case temperature (Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause permanent damage and void the product warranty.
Allow sufficient clear air space for the LED drivers, as well as suitable access to the drivers as specified on installation instructions. -
REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service Call for factory repair or replacement. Light source is not user replaceable. See page 5 for Ecodesign and end of life information.
ACCESSORIES
CHECK FIRST
- TURN OFF POWER
- CHECK THE WALL
INSTALLATION
Plan Installation
Check the product and its dimensions against the planned installation. Runs of LEDs may have to be installed in a particular sequence. 105mm – 2005mm length -1195g per meter.
Prepare Power Supply
This product requires a 24VDC power supply. Please refer to the provided wiring guide document. Failure to follow the guide may result in damage to the product and the voiding of the warranty.
Cable Exit
Plan cable entry and exit points before installing the product. Make a suitably sized hole for the cable/s to pass through, and position beneath where the product is planned to be placed.
Mounting Clips
Fix all the clips securely to the mounting surface. The recommended screw size is no greater than Ø4.00mm in diameter. Use fixings suitable for the material being fixed into. Products should be held with equally spaced clips (see accessories for quantity per meter). Products shorter than 505mm may be held by just 2 clips. There must always be a clip within 100mm to 200mm of each end of the product.
Connect to LED Driver
With the power off. Feed the power cables to the Vero, connecting the product to the LED driver. Finalize all electrical connections and test the circuit. If the product does not function as expected, turn the power off immediately and check all connections.
Mount Product
Align clips and carefully push the product into the clips. Ensure the product is fully clipped in place and check it is not misaligned or misplaced due to screw heads or wires. Ensure that cables are not pinched when installed.
Protect exposed cable
Self-closing cable sleeving: VECA-SL001-R1
For outdoor applications, the power cable must be wrapped in cable sleeving to protect the cable from UV exposure. Trim sleeving to match cable length.
EASY MOUNT INSTALLATION
Plan Out Installation
Easy mount fixing orientation should be installed as shown
Measure and Drill Holes
Plan fixing hole positions, drill pilot holes, and cable entry/exit holes as
required.
Make a suitably sized hole for the cable/s to pass through, and position
beneath where the product is planned to be placed.
Fix to Mounting Surface
Fix the easy mount to the fixing surface using a screw fixing appropriate for
the mounting surface. Use a screw no bigger than Ø5mm. Allow for easy mount to
have some movement.
Install
Fit Vero to the easy mounts, making sure not to pinch cables when installing.
Close Latch
Secure Vero to the easy mounts by closing the latch. Check that the mounting
is secure.
Removing Vero
To remove, use a plastic pry tool. Following steps 4 and 5 in reverse.
ROTATION MOUNT INSTALLATION
Mount Positions
Adjust the positions of the mounts against the Vero profile by spacing the
mounts out as shown in the diagram, then tighten the screws using the provided
Allen key.
Mount the Vero
Fix the Vero to the mounting surface using a screw fixing appropriate for the mounting surface.
Adjust
Adjust the Vero to the desired position and lock of the angle of adjustment using the provided Allen key. Ensure that all adjustment screws are tightened.
EMERGENCY CHARGING LED
IMPORTANT
For products containing an emergency charging LED for use with emergency
packs. To identify, check the product as shown…
… Or, check the product label.
Product codes ending with“DBE” or “HAE” are products equipped with an
emergency charging LED.
INSTALLATION
TURN OFF THE POWER AND DISCONNECT THE BATTERY PACK BEFORE WORK COMMENCES.
Installation
Follow the installation guide as detailed on the previous page. Make
allowances for an additional pair of wires (emergency charging LED).
Cabling
Feed both LED and emergency charging LED cables back to the emergency pack
location. Protect cables with sleeving for outdoor installations (self-closing
cable sleeving: VECA-SL001-R1).
Connect Cables
Connect cables to the correct terminals found on the emergency pack.
LED is 24VDC and emergency charging LED is 3VDC, ensure the correct LED is
connected to the correct output.
Emergency charging LED’s polarity is important, showing either green or red
depending on the status of the emergency pack.
Finishing Up
Finalize all electrical connections and test the circuit. If the product does
not function as expected, turn the power off immediately and check all
connections.
ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of
Regulations (EU) 2019/2020 and (EU) 2019/2015.
The contained light source is an integrated part of the containing product and
its removal can only be done by causing permanent damage to the containing
product.
Therefore, the replacement of the
light source with the use of commonly available tools is not justified due to
its restricted mechanical, electrical, optical, thermal, and/or environmental
protection requirements.
DISMANTLING
Dismantling of the light source from the containing product at the end of
life: The containing product shall be cut to the length of the contained light
source and the light source mechanically detached from the containing product.
Containing product parts shall then be disassembled.
Containing products shall be separated from building material and/or from
other additional mounting accessories using a professional installer.
Separate control gear and light sources must be disposed of at certified
disposal companies by Directive 2012/19/EU (WEEE) in the EU and with Waste
Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK.
LUMINO is a member of the WEEE producer compliance scheme.
Registration number: WEE/MM8138AA
ENERGY RATING
This product contains light sources of energy efficiency classes as shown:
LED | CCT | 9.6W/m | 12W/m | 24W/m | 30W/m |
---|
ColorCORE
| 4000K| –| F| F| F
3500K| –| F| F| F
3000K| –| F| F| F
2700K| –| F| G| G
2500K| –| F| G| G
2200K| –| F| G| G
EQ
| 4000K| –| F| G| G
3000K| –| G| G| G
2700K| –| G| G| G
ColorTUNE
| 4000K – 2200K| –| –| F| –
3000K – 1800K| –| –| F| –
WarmDIM| 3000K| F| –| –| –
RGBW| RGB + 3000K| –| F| G| –
RGB| N/A
FAQ
Q: Can the product be submerged for more than 30 minutes?
A: No, the product is rated for temporary submersion for up to 30 minutes only.
Q: Can I replace the light source myself?
A: No, the light source is not user-replaceable. Contact LUMINO for repair or replacement.
Q: Are constant voltage LED drivers with overload protection required?
A: Yes, drivers must be SELV, constant voltage with both overload and short- circuit protection.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>