LUMINO A12E Miniature Lighting Profile Glass Shelves Instruction Manual
- June 6, 2024
- LUMINO
Table of Contents
A12E
INSTALLATION MANUAL
IMA12E_R2101
BEAM ANGLES
SPECIFICATION
GLASS RECOMMENDATIONS
- VAC DIM.
- VAC DIM.
Make an appropriate IP-rated connection.
Please refer to provided wiring guide document. Failure to follow the provided
guide may result in damage to the product and voiding of the warranty.
CABLE & CONNECTOR
VECA-CA0250-2PMF-R1
Power link, 250mm cable length
VECA-CA1000-2PMF-R1
Power link, 1000mm cable length
**** HANDLING PRECAUTIONS
PLASTIC COVER / DIFFUSER
To avoid permanent damage, do not allow small or sharp objects to apply
pressure onto the plastic cover/diffuser.
STRESS
Never stand or place weighted items on the product. The product is not
vandal resistant and has no IK rating. Do not subject the product to impact
forces.
POWER CABLES
The product end caps, power cables, and connectors must not be pulled or
twisted. Never pull the product by its power cables or hang it from its power
cables or connectors.
CUTTINGANDSAWING
The product must not be cut, sawn, drilled, or otherwise modified in any
way.
DAMAGES
Inspect the product and if you see any damage upon unpacking report to
LUMINO immediately and do not install the product.
LOCATION
Use in a dry location only. This product is unsuitable for wet and damp
locations. IP50 rated for dust protection.
Protect products from dust, paint, and harmful substances during installation
and use. Ensure the product is not exposed to VOC gases.
**** SAFETY GUIDANCE
WIRING GUIDE
Follow the guidance shown in the provided wiring guide including maximum cable
lengths, cable sizes, and other wiring instructions. When running cables
through an enclosure, ensure cables are protected from damage, separated from
mains voltage cables, and anchored against being pulled.
QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in
accordance with local regulations and applicable standards.
THERMAL MANAGEMENT
This LED module does not require specific thermal management but installers
must note that the product is rated for use in an ambient air temperature (Ta)
not exceeding 30°C (86°F) and a case temperature (Tc) not exceeding 60°C
(140°F). Exceeding maximum Tc will cause permanent damage and void the product
warranty.
Allow sufficient clear air space for the LED drivers, as well as suitable
access to the drivers as specified on installation instructions.
REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service
Call for factory repair or replacement.
DRIVERS
POWER OFF
Product and driver must not be live wired. Switch off the power before work
begins. Follow instructions and guidance for the make and model of the driver
being used.
24VDC SELV
Ensure supply voltage does not exceed 24VDC.
Only use drivers with a maximum output of 24VDC.
Drivers must be SELV constant voltage type with both overload and short-
circuit protection.
INRUSH CURRENT
Many constant voltages LED drivers can have a high inrush current at power-
on. Driver inrush current can be many times the normal operating current. Use
a suitable MCB. Type C MCBs are normally suitable but if inrush current is a
persistent problem an inrush suppressor may be required.
PROTECTION
Use only with 24VDC Class 2 power unit to UL1310 standard with overload and
short-circuit protection. Rate drivers for at least 10% above load. Driver
protection circuitry must not be relied upon to protect secondary 24VDC
electrical circuits from damage caused by over-current or short circuits. DC
fuses or DC electronic circuit breakers are recommended for full protection.
Allow for access to drivers for maintenance and sufficient clear air space for
ventilation.
CABLING
Do not overload the driver. Damage will be caused by incorrect input
voltage, reverse polarity, or a short circuit. Plan for loads, driver
locations, dimming, and cabling prior to the start of work. Ensure basic
insulation is maintained between mains and dimming control wires.
TECHNICAL SUPPORT
+44(0) 1279 635 411
www.lumino.lighting
LUMINO DISTRIBUTION LTD
Lumino House, Lovet Road
Harlow, Essex CM19 5TB
United Kingdom
Installers must read this document and any other referenced documents in full
before commencing installation work.
Failure to observe all installation guidance in this document may result in
unsafe installation, cause permanent product damage, and void product
warranty.
This document is subject to change without notice.