- 8 AWG| RED| 49-12-U008C| 8| | ****
- 6 AWG| BLUE| 49-12-U006C| 6
- 4 AWG| GRAY| 49-12-U004C| 4| ****
- 2 AWG| BROWN| 49-12-U002C| 2
- 1 AWG +| GREEN| 49-12-U001C| 1
- 8 AWG| BLUE| 49-12-U008| 8| ****
- 6 AWG| GRAY| 49-12-U006| 6
- 4 AWG| GREEN| 49-12-U004| 4
- 2 AWG| PINK| 49-12-U002| 2| 1| 1| 1
- 1 AWG| GOLD| 49-12-U001| 1| ****
- 8 AWG| RED| 49-12-U008C| 8| | ****
- 6 AWG| BLUE| 49-12-U006C| 6
- 4 AWG| GRAY| 49-12-U004C| 4| ****
- 2 AWG| BROWN| 49-12-U002C| 2
- 1 AWG| GREEN| 49-12-U001C| 1| | | | | | |
- 8 AWG| BLUE| 49-12-U008| 8| ****
- 6 AWG| GRAY| 49-12-U006| 6
- 4 AWG| GREEN| 49-12-U004| 4
- 2 AWG| PINK| 49-12-U002| 2| 1| 1| 1
- 1 AWG| GOLD| 49-12-U001| 1| ****
- SYMBOLOGY
- SPECIFICATIONS
- FUNCTIONAL DESCRIPTION
- ASSEMBLY
- OPERATION
- **MAINTENANCE
- ACCESSORIES
- WIRELESS COMMUNICATION
- SERVICE – UNITED STATES
- LIMITED WARRANTY USA & CANADA
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
OPERATOR’S MANUAL
Cat. No. / No de cat.
2779-20
2779-20 M18 Force Logic 750 Mcm Crimper
M18™ FORCE LOGIC™ 750 MCM CRIMPER
SERTISSEUR UTILITAIRE 750 MCM M18™ FORCE LOGIC™
CRIMPADORA 750 MCM UTILITARIA M18™ FORCE LOGIC™
WARNING To reduce the risk of injury, user must read and understand
operator’s manual.
GENERAL POWER TOOL SAFETY WARNINGS
WARNING
Read all safety warnings, instructions, illustrations and specifica- tions
provided with this power tool. Failure to follow all instructions listed below
may result in electric shock, fire and/or serious injury. Save all warnings
and instructions for future reference. The term “power tool” in the warnings
refers to your mains-operated (corded) power tool or battery-operated
(cordless) power tool.
WORK AREA SAFETY
- Keep work area clean and well lit. Cluttered or dark areas invite accidents.
- Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases or dust. Power tools create sparks which may ignite the dust or fumes.
- Keep children and bystanders away while operating a power tool. Distractions can cause you to lose control.
ELECTRICAL SAFETY
- Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools. Unmodified plugs and matching outlets will reduce risk of electric shock.
- Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators. There is an increased risk of electric shock if your body is earthed or grounded.
- Do not expose power tools to rain or wet conditions. Water entering a power tool will increase the risk of electric shock.
- Do not abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged or entangled cords increase the risk of electric shock.
- When operating a power tool outdoors, use an extension cord suitable for outdoor use. Use of a cord suitable for outdoor use reduces the risk of electric shock.
- If operating a power tool in a damp location is unavoidable, use a ground fault circuit interrupter (GFCI) protected supply. Use of an GFCI reduces the risk of electric shock.
PERSONAL SAFETY
- Stay alert, watch what you are doing and use common sense when operating a power tool. Donot use a power tool while you are tired or underthe influence of drugs, alcohol or medication. A moment of inattention while operating power tools may result in serious personal injury.
- Use personal protective equipment. Alwayswear eye protection. Protective equipment such as a dust mask, non-skid safety shoes, hard hat or hearing protection used for appropriate conditions will reduce personal injuries.
- Prevent unintentional starting. Ensure the switch is in the off-position before connecting to power source and/or battery pack, picking up or carrying the tool. Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents.
- Remove any adjusting key or wrench before turning the power tool on. A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
- Do not overreach. Keep proper footing and balance at all times. This enables better control of the power tool in unexpected situations.
- Dress properly. Do not wear loose clothing or jewelry. Keep your hair and clothing away from moving parts. Loose clothes, jewelry or long hair can be caught in moving parts.
- If devices are provided for the connection of dust extraction and collection facilities, ensure these are connected and properly used. Use of dust collection can reduce dust-related hazards.
- Do not let familiarity gained from frequent use of tools allow you to become complacent and ignore tool safety principles. A careless action can cause severe injury within a fraction of a second.
POWER TOOL USE AND CARE
- Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed.
- Do not use the power tool if the switch does not turn it on and off. Any power tool that cannot be controlled with the switch is dangerous and must be repaired.
- Disconnect the plug from the power source and/ or remove the battery pack, if detachable, from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
- Store idle power tools out of the reach of children and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
- Maintain power tools and accessories. Check for misalignment or binding of moving parts, breakage of parts and any other condition that may affect the power tool’s operation. If damaged, have the power tool repaired before use. Many accidents are caused by poorly maintained power tools.
- Keep cutting tools sharp and clean. Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
- Use the power tool, accessories and tool bits etc. in accordance with these instructions, taking into account the working conditions and the work to be performed. Use of the power tool for operations different from those intended could result in a hazardous situation.
- Keep handles and grasping surfaces dry, clean and free from oil and grease. Slippery handles and grasping surfaces do not allow for safe handling and control of the tool in unexpected situations.
BATTERY TOOL USE AND CARE
- Recharge only with the charger specified by the manufacturer. A charger that is suitable for one type of battery pack may create a risk of fire when used with another battery pack.
- Use power tools only with specifically desig- nated battery packs. Use of any other battery packs may create a risk of injury and fire.
- When battery pack is not in use, keep it away from other metal objects, like paper clips, coins, keys, nails, screws or other small metal objects, that can make a connection from one terminal to another. Shorting the battery terminals together may cause burns or a fire.
- Under abusive conditions, liquid may be ejected from the battery; avoid contact. If contact accidentally occurs, flush with water. If liquid contacts eyes, additionally seek medical help. Liquid ejected from the battery may cause irritation or burns.
- Do not use a battery pack or tool that is damaged or modified. Damaged or modified batteries may exhibit unpredictable behavior resulting in fire, explosion or risk of injury.
- Do not expose a battery pack or tool to fire or excessive temperature. Exposure to fire or temperature above 265°F (130°C) may cause explosion.
- Follow all charging instructions and do not charge the battery pack or tool outside the temperature range specified in the instructions. Charging improperly or at temperatures outside the specified range may damage the battery and increase the risk of fire.
SERVICE
- Have your power tool serviced by a qualified repair person using only identical replacement parts. This will ensure that the safety of the power tool is maintained.
- Never service damaged battery packs. Service of battery packs should only be performed by the manufacturer or authorized service providers.
SPECIFIC SAFETY RULES FOR CRIMPER
- Use tool only as directed. Only trained personnel should operate tool.
- To reduce the risk of arc flash, WARNING electric shock and property damage, work on deenergized lines when possible. Tool is not insulated. Should work on energized lines be required, ensure all proper precautions, including those contained in NFPA 70E, have been taken first.
- Use tool only with MILWAUKEE “U” dies and connectors for which they are rated. Jaws, dies, and connectors must be used in an APPROVED COMBINATION to achieve a successful operation. Improper combinations can result in a faulty crimp. Electric shock, fire, explosion, and property damage could occur.
- Keep hands away from crimping jaws while tool is in use. Fingers could be crushed.
- To reduce the risk of injury, wear safety goggles or glasses with side shields when operating or servicing the tool.
- Inspect and discard workpieces with cracks or wear before use. Materials may crack or shatter.
- Follow connector manufacturers’ installation instructions. Other uses may cause damage to the tool, accessories, and workpiece.
- For best results, use only with energy absorbing lanyards. Ropes, straps or chains may break and cause failure. Do not use with lanyards at full tension.
- Chemical Burn Hazard. Keep coin cell battery away from children.
- Always use common sense and be cautious when using tools. It is not possible to anticipate every situation that could result in a dangerous outcome. Do not use this tool if you do not understand these operating instructions or you feel the work is beyond your capability; contact Milwaukee Tool or a trained professional for additional information or training.
- Maintain labels and nameplates. These carry important information. If unreadable or missing, contact a MILWAUKEE service facility for a free replacement.
- WARNING Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known to cause cancer, birth defects or other reproductive harm. Some examples of these chemicals are:
- lead from lead-based paint
- crystalline silica from bricks and cement and other masonry products, and arsenic and chromium from chemically-treated lumber. Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specially designed to filter out microscopic particles.
Connections made with this tool (2779-20) and combination of die and connector part numbers in the charts below produce UL classified crimps according to the UL 486A-B standard.
Table A – United States
| Copper Short & Long Barrel Lugs & Splices
---|---
Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
Splice Model #’s| VHS, VHSS| CSP, CU| YS, YS-L, YS-T| CT, CTL| SCH, SCL,
SCS, SCSS| BBCU, BCU| 54504-54523-TB,
54804-54823
Lug Model #’s
| ****
VHCL, VHCS
| ****
CTL, CTL-2,
CTL-L, LCN
| YA, YAZ, YA-L,
YA-2L, YA-2LN, YA-L-NT, YA-L-2NT,
YA-L-TC, YA-L-2TC, YA-2N, YA-TC,
YA-2TC
| CLN, CLND, CLNS, CLW, CLWD, CRA, CRB, CRA-L, CRB- L, CRA-2L, CRB-2L, CSW, CSWS| ****
LCA, LCAS, LCB, LCC, LCD
| ****
BBLU, BLU
| ****
54104-54123-TB,
54204-54223,
54850BE-54880BE,
54930BE-54923BE
Wire Size (Code only)
| ****
Die Color
| ****
Cat. No.
| Die Indentation Mark| Lugs: Total # of Crimps Splices: # of Crimps
per Side
Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
8 AWG| RED| 49-12-U008C| 8| | ****
1
| ****
1
| ****
1
| ****
1
| ****
1
| ****
1
6 AWG| BLUE| 49-12-U006C| 6
4 AWG| GRAY| 49-12-U004C| 4| ****
1
2 AWG| BROWN| 49-12-U002C| 2
1 AWG +| GREEN| 49-12-U001C| 1
1/0 AWG| PINK| 49-12-U01AC| 1/0
2/0 AWG| BLACK| 49-12-U02AC| 2/0
3/0 AWG| ORANGE| 49-12-U03AC| 3/0
4/0 AWG| PURPLE| 49-12-U04AC| 4/0
250 MCM| YELLOW| 49-12-U250C| 250
300 MCM| WHITE| 49-12-U300C| 300| 2| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
350 MCM| RED| 49-12-U350C| 350| Lugs: 2 Splices: N/A
400 MCM| BLUE| 49-12-U400C| 400| ****
2
500 MCM| BROWN| 49-12-U500C| 500
600 MCM| GREEN| 49-12-U600C| 600
750 MCM| BLACK| 49-12-U750C| 750
+ Concentric or Compressed only
Dual Rated Lugs & Splices
| Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
Splice Model #’s| VACS| ASP| YS-A| AS,ASN| SA| BCUA| 60501-60578
Lug Model #’s| VACL| ATL| YA-A, YA-ATN| ACL, ACN,ALND, ALNS, 2ACL, 2ACN,
ALNN| LAA, LAB| BLUA| 60101-60178,
60230-60278
Wire Size (Code only)| Die Color| ****
Cat. No.
| Die Indentation Mark| Lugs: Total # of Crimps Splices: # of Crimps
per Side
Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
8 AWG| BLUE| 49-12-U008| 8| ****
Lugs: N/A
Splices: 1
| ****
Lugs: 1 Splices: N/A
| ****
1
| ****
1
| | ****
Lugs: 1
Splices: N/A
| ****
1
6 AWG| GRAY| 49-12-U006| 6
4 AWG| GREEN| 49-12-U004| 4
2 AWG| PINK| 49-12-U002| 2| 1| 1| 1
1 AWG| GOLD| 49-12-U001| 1| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
1/0 AWG| TAN| 49-12-U01A| 1/0
2/0 AWG| OLIVE| 49-12-U02A| 2/0
3/0 AWG| RUBY| 49-12-U03A| 3/0
4/0 AWG| WHITE| 49-12-U04A| 4/0
250 MCM| RED| 49-12-U250| 250
300 MCM| BLUE| 49-12-U300| 300
350 MCM| BROWN| 49-12-U350| 350
400 MCM| GREEN| 49-12-U400| 400| ****
3
| ****
3
| ****
3
| ****
3
| ****
3
| ****
3
| ****
3
500 MCM| PINK| 49-12-U500| 500
600 MCM| BLACK| 49-12-U600| 600
750 MCM| YELLOW| 49-12-U750| 750
Table B – Canada and Mexico
| Copper Short & Long Barrel Lugs & Splices
---|---
Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
Splice Model #’s| VHS, VHSS| CSP, CU| YS, YS-L, YS-T| CT, CTL| SCH, SCL,
SCS, SCSS| BBCU, BCU| 54504-54523-TB,
54804-54823
Lug Model #’s
| ****
VHCL, VHCS
| ****
CTL, CTL-2,
CTL-L, LCN
| YA, YAZ, YA-L,
YA-2L, YA-2LN, YA-L-NT, YA-L-2NT,
YA-L-TC, YA-L-2TC, YA-2N, YA-TC,
YA-2TC
| CLN, CLND, CLNS, CLW, CLWD, CRA, CRB, CRA-L, CRB- L, CRA-2L,
CRB-2L, CSW, CSWS
| ****
LCA, LCAS, LCB, LCC, LCD
| ****
BBLU, BLU
| ****
54104-54123-TB,
54204-54223,
54850BE-54880BE,
54930BE-54923BE
Wire Size (Code only)
| ****
Die Color
| ****
Cat. No.
| Die Indentation Mark| Lugs: Total # of Crimps Splices: # of Crimps
per Side
Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
8 AWG| RED| 49-12-U008C| 8| | ****
1
| ****
1
| ****
1
| ****
1
| ****
1
| ****
1
6 AWG| BLUE| 49-12-U006C| 6
4 AWG| GRAY| 49-12-U004C| 4| ****
1
2 AWG| BROWN| 49-12-U002C| 2
1 AWG| GREEN| 49-12-U001C| 1| | | | | | |
1/0 AWG| PINK| 49-12-U01AC| 1/0| ****
1
| ****
1
| ****
1
| ****
1
| ****
1
| ****
1
| ****
1
2/0 AWG| BLACK| 49-12-U02AC| 2/0
3/0 AWG| ORANGE| 49-12-U03AC| 3/0
4/0 AWG| PURPLE| 49-12-U04AC| 4/0
250 MCM| YELLOW| 49-12-U250C| 250
300 MCM| WHITE| 49-12-U300C| 300| 2| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
350 MCM| RED| 49-12-U350C| 350| Lugs: 2 Splices: N/A
400 MCM| BLUE| 49-12-U400C| 400| ****
2
500 MCM| BROWN| 49-12-U500C| 500
600 MCM| GREEN| 49-12-U600C| 600
750 MCM| BLACK| 49-12-U750C| 750
Dual Rated Lugs & Splices
| Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
Splice Model #’s| VACS| ASP| YS-A| AS,ASN| SA| BCUA| 60501-60578
Lug Model #’s| VACL| ATL| YA-A, YA-ATN| ACL, ACN,ALND, ALNS, 2ACL, 2ACN,
ALNN| LAA, LAB| BLUA| 60101-60178,
60230-60278
Wire Size (Code only)| Die Color| ****
Cat. No.
| Die Indentation Mark| Lugs: Total # of Crimps Splices: # of Crimps
per Side
Anderson| Blackburn ®| Burndy| ILSCO| Panduit|
Penn-Union| T &B
8 AWG| BLUE| 49-12-U008| 8| ****
Lugs: N/A
Splices: 1
| ****
Lugs: 1 Splices: N/A
| ****
1
| ****
1
| | ****
Lugs: 1
Splices: N/A
| ****
1
6 AWG| GRAY| 49-12-U006| 6
4 AWG| GREEN| 49-12-U004| 4
2 AWG| PINK| 49-12-U002| 2| 1| 1| 1
1 AWG| GOLD| 49-12-U001| 1| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
| ****
2
1/0 AWG| TAN| 49-12-U01A| 1/0
2/0 AWG| OLIVE| 49-12-U02A| 2/0
3/0 AWG| RUBY| 49-12-U03A| 3/0
4/0 AWG| WHITE| 49-12-U04A| 4/0
250 MCM| RED| 49-12-U250| 250
300 MCM| BLUE| 49-12-U300| 300
350 MCM| BROWN| 49-12-U350| 350
400 MCM| GREEN| 49-12-U400| 400| ****
3
| ****
3
| ****
3
| ****
3
| ****
3
| ****
3
| ****
3
500 MCM| PINK| 49-12-U500| 500
600 MCM| BLACK| 49-12-U600| 600
750 MCM| YELLOW| 49-12-U750| 750
Number of crimps is a minimum. Additional crimps would not negatively affect the integrity of the connection so long as they are uniformly placed between the intended crimp area of the connector, typically outlined with color bands or knurls. For the latest listing of approvals, visit milwaukeetool.com. For technical or service assistance, contact Milwaukee Customer Service at 1-800-729-3878.
SYMBOLOGY
V | Volts |
---|---|
Direct Current | |
Underwriters Laboratories, Inc. | |
WARNING |
To reduce the risk of arcflash, electric shock andproperty damage, work on
deenergizedlines when possible. Tool is not insulated.
Should work on energized lines be required, ensure all proper precautions,
including those contained in NFPA 70E,have been taken first.
| WARNING Keep hands away fromcrimping jaws while tool is in use. Fingers
could be crushed.
| To reduce the risk of injury, wear safety goggles or glasses with side
shields when operating or servicing the tool.
| Read operator’s manual.
SPECIFICATIONS
Cat. No. …………………………………………….. 2779-20
Volts …………………………………………………….. 18 DC
Battery Type ………………………………………….M18™
Charger Type …………………………………………M18™
Module/FCC ID ………………… BLE113/QOQBLE113
Force ………………………………………………….12 Tons
Capacity…………………………….. #8AWG – 750 MCM
Recommended Ambient
Operating Temperature ………………….0°F to 122°F
FUNCTIONAL DESCRIPTION
- Crimping jaws
- Lift ring
- LEDs/Crimping indicator
- Internal battery
- ONE KEY TM indicator
- Handle
- Reverse trigger
- Trigger
- Die release pins
ASSEMBLY
WARNING Recharge only with the charger specified for the battery. For
specific charging instructions, read the operator’s manual supplied with your
charger and battery.
Removing/Inserting the Battery
To remove the battery, push in the release buttons and pull the battery pack
away from the tool.
WARNING Always remove battery pack before changing or removing
accessories.
To insert the battery, slide the pack into the body of the tool. Make sure it
latches securely into place.
WARNING Only use accessories specifically recommended for this tool.
Others may be hazardous.
An incomplete or faulty crimp could cause a fire. Use tool only with
MILWAUKEE “U” dies and connectors for which they are rated. Jaws, dies,
and connectors must be used in an approved combination to achieve a
successful operation. Improper combinations can result in a faulty
crimp. Electric shock, fire, explosion, and property damage could
occur.
Changing the Dies
Inspect dies and connectors before use. Only use properly matched dies and
connectors for the crimping jaws. Refer to Specifications for die/connector
compatibility.
- Remove the battery pack.
- Snap the appropriate dies into each side of the crimping jaws.
- To remove, press the release button for each side of the crimping jaws. Pull dies out from crimping jaws.
ONE-KEY™
To learn more about the ONE-KEY™ functionality for this tool, go to
milwaukeetool.com/One-Key. To download the ONE-KEY™ app, visit the App Store
or Google Play from your smart device.
ONE-KEY™ Indicator
Solid Blue| Wireless mode is active and ready to be configured via the ONE-
KEY™ app.
Blinking Blue| Tool is actively communicating with the ONE-KEY™ app.
Blinking Red| Tool is in security lockout and can be unlocked by the owner via
the ONE-KEY™ app.
OPERATION
WARNING
To reduce the risk of arc flash, electric shock and property damage, work on
deenergized lines when possible. Tool is not insulated. Should work on
energized lines be required, ensure all proper precautions, including those
contained in NFPA 70E, have been taken first.
Keep hands away from crimping jaws while tool is in use. Fingers could be
crushed. Always remove battery pack before changing or removing accessories.
Only use accessories specifically recommended for this tool. Others may be
hazardous. Always wear proper eye protection marked to comply with ANSI Z87.1.
Crimping
Before crimping:
- Inspect the jaws and dies for cracks or other damage. Do not use damaged jaws or dies. Contact a MILWAUKEE service facility.
- Ensure dies are properly installed.
- Jaws, dies, connectors, and cables must be used in an APPROVED COMBINATION. Improper combinations can result in a faulty crimp.
- Inspect and discard workpieces with cracks or wear before use. Materials may crack or shatter.
- Follow installation specifications as specified in Table A or B using an Approved Combination of jaws, dies, connectors and cables as indicated. Other uses may cause damage to the tool, accessories, and workpiece.
1. Install the dies.
2. Insert battery pack.
3. Rotate the jaws to the desired angle. Hold tool securely. Press and hold the trigger.
4. When the cycle is complete the tool will switch off and the indicator will light. Release the trigger. Press and hold the reverse trigger to manually return the crimping jaws.
NOTE: After the cycle reaches a certain point, the crimp may automatically finish, even if the trigger is released. LED Indicator| Definition
---|---
Solid Green| Tool completed the operation and reached full crimping pressure.
Solid Red| Tool completed the operation but did NOT reach full crimping pressure.
Flashing Red| Tool did NOT complete the operation.
Flashing Red/Green (after Solid Green or Solid Red)| Tool has reached its service interval (20,000 crimps). Red/Green flashing will begin after the solid Red or Green indicator for the operation is displayed. MILWAUKEE recommends that the tool be inspected and preventative maintenance completed. Return tool to a MILWAUKEE service facility.
5. Continue crimping according to the instructions in Table A or B, or the connector manufacturer’s installation instructions.
- Crimps should be uniformly placed on the barrel of the connector.
- Crimps should be reasonably placed within the color bands or knurled area of the connector.
- For splices, begin crimping in the center, working outward while alternating sides.
- For lugs, begin crimping near the pad, working towards the barrel.
6. An LED will light the workpiece when the trigger is pulled.
7. The die identifier is pressed into the connector during the crimp.
**MAINTENANCE
**
WARNING
To reduce the risk of injury, always unplug the charger and remove the
battery pack from the charger or tool beforeperforming any maintenance. Never
disassemble the tool, battery pack or charger. Contact a MILWAUKEE service
facility for ALL repairs.
Maintaining Tool
Keep your tool, battery pack and charger in good repair by adopting a regular
maintenance program. Inspect your tool for issues such as undue noise,
misalignment or binding of moving parts, breakage of parts, or any other
condition that may affect the tool operation. Return the tool, battery pack,
and charger to a MILWAUKEE service facility for repair. After six months to
one year, depending on use, return the tool, battery pack and charger to a
MILWAUKEE service facility for inspection.
If the tool does not start or operate at full power with a fully charged
battery pack, clean the contacts on the battery pack. If the tool still does
not work properly, return the
tool, charger and battery pack, to a MILWAUKEE service facility for repairs.
ONE-KEY™
Refer to the ONE-KEY App for information regarding necessary servicing, such
as internal battery life and crimp count.Chemical Burn Hazard.
WARNING
This device contains a lithium button/coin cell battery. A new or used battery
can cause severe internal burns and lead to death in as little as 2 hours if
swallowed or enters the body. Always secure the battery cover. If it does not
close securely, stop using the device, remove the batteries, and keep it away
from children. If you think batteries may have been swallowed or entered the
body, seek immediate medical attention.
Internal Coin Cell Battery
An internal coin cell battery is used to facilitate full ONE-KEY™
functionality.
To replace the coin cell battery:
- Remove the battery pack.
- Remove the screw(s) and open the coin cell battery door.
- Remove the old coin cell battery, keep it away from children, and dispose of it properly.
- Insert the new coin cell battery (3V CR2032), with the positive side facing up.
- Close the battery door and tighten the screw(s) securely.
WARNING To reduce the risk of personal injury and damage, never immerse
your tool, battery pack or charger in liquid orallow a liquid to flow inside
them.
Cleaning
Clean dust and debris from vents. Keep handles clean, dry and free of oil or
grease. Use only mild soap and a damp cloth to clean, since certain cleaning
agents and solvents are harmful to plastics and other insulated parts. Some of
these include gasoline,turpentine, lacquer thinner, paint thinner,
chlorinatedcleaning solvents, ammonia and household detergents containing
ammonia. Never use flammable or combustible solvents around tools.
Repairs
For repairs, return the tool, battery pack and charger to the nearest
authorized service center.
ACCESSORIES
WARNING
Use only recommended accessories. Others may be hazardous.
For a complete listing of accessories, go online to
www.milwaukeetool.com or contact a
distributor.
WIRELESS COMMUNICATION
For products provided with wireless communication features, including ONE-
KEY™:
Pursuant to part 15.21 of the FCC Rules, do not modify this product.
Modification could void your authority to operate the product. This device
complies with part 15 of the FCC Rules and ISED-Canada’s license exempt RSS
standards. Operation is subject to the following two conditions: 1) This
device may not cause harmful interference, and 2) This device must accept any
interference received, including interference that may cause undesired
operation.
SERVICE – UNITED STATES
1-800-SAWDUST (1.800.729.3878)
Monday-Friday, 7:00 AM – 6:30 PM CST or visit
www.milwaukeetool.com
Contact Corporate After Sales Service Technical Support with technical,
service/repair, or warranty questions.
Email:
metproductsupport@milwaukeetool.com
Become a Heavy Duty Club Member at
www.milwaukeetool.com to receive important
notifications regarding your tool purchases.
LIMITED WARRANTY USA & CANADA
Every MILWAUKEE power tool* (see exceptions below) is warranted to the
original purchaser only to be free from defects in material and workmanship.
Subject to certain exceptions, MILWAUKEE will repair or replace any part on an
electric power tool which, after examination, is determined by MILWAUKEE to be
defective in material or workman- ship for a period of five (5) years* after
the date of purchase unless otherwise noted. Return of the power tool to a
MILWAUKEE factory Service Center location or MILWAUKEE Authorized Service
Station, freight prepaid and insured, is required. A copy of the proof of
purchase should be included with the return product. This warranty does not
apply to damage that MILWAUKEE determines to be from repairs made or attempted
by anyone other than MILWAUKEE authorized personnel, misuse, alterations,
abuse, normal wear and tear, lack of maintenance, or accidents. Normal Wear:
Many power tools need periodic parts replacement and service to achieve best
performance. This warranty does not cover repair when normal use has exhausted
the life of a part including, but not limited to, chucks, brushes, cords, saw
shoes, blade clamps, o-rings, seals, bumpers, driver blades, pistons,
strikers, lifters, and bumper cover washers. This warranty does not cover Air
Nailers & Staplers; Airless Paint Sprayer; Cordless Battery Packs; Gasoline
Driven Portable Power Generators; Hand Tools; Hoist – Electric, Lever & Hand
Chain; M12™ Heated Gear; Reconditioned Product; and Test & Measurement
Products. There are separate and distinct warranties available for these
products. **The warranty period for Job Site Radios, M12™ Power Port, M18™
Power Source, Jobsite Fan and Trade Titan™ Industrial Work Carts is one (1)
year from the date of purchase. The warranty period for the M18 FUEL™ 1″
D-Handle High Torque Impact Wrenches, Drain Cleaning Cables, AIRSNAKE™ Drain
Cleaning Air Gun Accessories, REDLITHIUM™ USB Laser Levels, TRAPSNAKE™ 25′
Auger w/ CABLE DRIVE™, FORCE LOGIC™ Press Tool Accessories and Green Cross
Line Laser is two (2) years from the date of purchase. The warranty period for
the M18™ Compact Heat Gun, 8 Gallon Dust Extractor, M18™ Framing Nailers, M18
FUEL™ 1/2″ Ext. Anvil Controlled Torque Impact Wrench w/ ONE-KEY™, M18 FUEL™
1″ High Torque Impact Wrench w/ ONE-KEY™, M18 FUEL™ 2 Gal. Compact Quiet
Compressor, M12™ Laser Levels, 165′ Laser Detector, M12™ 23GA Pin Nailer, M18
FUEL™ 1/4″ Blind Rivet Tool w/ ONE-KEY™, M12 FUEL™ Low Speed Tire Buffer, M18
FUEL™ Random Orbital Polishers, M18™ Utility Fencing Stapler, and the 72″
Laser Tripod is three (3) years from the date of purchase. The warranty period
for the LED in the LED Work Light and the LED Upgrade Bulb for the Work Light
is the lifetime of the product subject to the limitations above. If during
normal use the LED or LED Bulb fails, the part will be replaced free of
charge. Warranty Registration is not necessary to obtain the applicable
warranty on a MILWAUKEE power tool product. The manufacturing date of the
product will be used to determine the warranty period if no proof of purchase
is provided at the time warranty service is requested.
ACCEPTANCE OF THE EXCLUSIVE REPAIR AND REPLACEMENT REMEDIES DESCRIBED HEREIN
IS A CONDITION OF THE CONTRACT FOR THE PURCHASE OF EVERY MILWAUKEE PRODUCT. IF
YOU DO NOT AGREE TO THIS CONDITION, YOU SHOULD NOT PURCHASE THE PRODUCT. IN NO
EVENT SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL, SPECIAL, CONSEQUENTIAL OR
PUNITIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY FEES, EXPENSES, LOSSES OR DELAYS
ALLEGED TO BE AS A CONSEQUENCE OF ANY DAMAGE TO, FAILURE OF, OR DEFECT IN ANY
PRODUCT INCLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR LOSS OF PROFITS. SOME
STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS
WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES, WRITTEN OR
ORAL. TO THE EXTENT PERMITTED BY LAW, MILWAUKEE DISCLAIMS ANY IMPLIED
WARRANTIES, INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR USE OR PURPOSE; TO THE EXTENT SUCH
DISCLAIMER IS NOT PERMITTED BY LAW, SUCH IMPLIED WARRANTIES ARE LIMITED TO THE
DURATION OF THE APPLICABLE EXPRESS WARRANTY AS DESCRIBED ABOVE. SOME STATES DO
NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE
LIMITATION MAY NOT APPLY TO YOU, THIS WARRANTY GIVES YOU SPECIFIC LEGAL
RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE.
This warranty applies to product sold in the U.S.A. and Canada only. Please
consult the ‘Service Center Search’ in the Parts & Service section of
MILWAUKEE’s website www.milwaukeetool.com or
call 1.800. SAWDUST (1.800.729.3878) to locate your nearest service facility
for warranty and non-warranty service on a Milwaukee electric power tool.
SERVICE – CANADA
Milwaukee Tool (Canada) Ltd
1.877.948.2360
Monday-Friday, 7:00 AM – 4:30 PM CST
or visit www.milwaukeetool.ca
MILWAUKEE TOOL
13135 West Lisbon Road Brookfield, WI 53005 USA
58142779d5 961014625-01(A)
08/22 Printed in China
References
- Milwaukee® Tool Official Site | Nothing but HEAVY DUTY®
- Milwaukee® Tool Official Site | Nothing but HEAVY DUTY®
- Track Tools with ONE-KEY™: Free Inventory App by Milwaukee®
- Milwaukee® Tool Official Site | Nothing but HEAVY DUTY®
- Milwaukee® Tool Official Site | Nothing but HEAVY DUTY®
- Sitio oficial de Milwaukee® Tool | Nothing but HEAVY DUTY®
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>