V36SIP64
TECHNICAL SUPPORT
+44(0) 1279 635 411
www.lumino.lighting
LUMINO DISTRIBUTION LTD
Lumino House, Lovet Road
Harlow, Essex CM19 5TB
United Kingdom
Installers must read this document and any other referenced documents in full
before commencing installation work. Failure to observe all installation
guidance in this document may result in unsafe installation, cause permanent
product damage and void product warranty.
This document is subject to change without notice. Check for latest
documentation with LUMINO. Copyright © LUMINO. E&OE
HANDLING PRECAUTIONS
-
PLASTIC COVER / DIFFUSER
To avoid permanent damage, do not allow small or sharp objects to apply pressure on to the plastic cover / diffuser. -
IMPACT PROTECTION
The product is not vandal resistant. Never stand or place weighted items on the product. This product has a maximum IK rating of IK08. -
POWER CABLES
The product end caps, power cables and connectors must not be pulled or twisted. Never pull the product by its power cables or hang it from its power cables or connectors. -
CUTTING AND SAWING
The product must not be sawn, drilled or otherwise modified in any way. -
DAMAGES
Inspect the product. If you see any damage upon unpacking, report to LUMINO immediately and do not install the product. -
LOCATION
Suitable for damp locations. IP64 rated product is dust tight and protected against water splashes.
Protect product from dust, paint and harmful substances during installation and use. Ensure product is not exposed to VOC gases. Do not obstruct the product and its light output.
SAFETY GUIDANCE
WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum
cable lengths, cable sizes and other wiring instructions. When running cables
through an enclosure, ensure cables are protected from damage, separated from
mains voltage cables and anchored against being pulled. Make connections
appropriate for the IP rating of the product.
QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in
accordance with local regulations and applicable standards.
THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case
temperature
(Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause permanent
damage and void the product warranty.
Allow sufficient clear air space for the LED drivers, as well as suitable
access to the drivers as specified on installation instructions.
REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service Call
for factory repair or replacement. Light source is not user replaceable. See
page 5 for Eco design and end of life information.
DRIVERS
POWER OFF
Product and driver must not be live wired. Switch off power before work
begins. Follow instructions and guidance for the make and model of driver
being used.
24VDC SELV
Only use drivers with a maximum output of 24VDC. Drivers must be SELV,
constant voltage with both overload and short-circuit protection.
DIMMERS
Check dimmer is compatible with the driver and certified to local regulations.
INRUSH CURRENT
Many constant voltage LED drivers can have high in rush current at power-on.
Driver’s inrush current can be many times the normal operating current. Use a
suitable MCB. Type C MCBs are normally suitable but if inrush current is a
persistent problem an inrush suppressor may be required.
PROTECTION
Use only with 24VDC Class 2 power unit toUL1310 standard with overload and
short-circuit protection. Rate drivers for at least 10% above load. Driver
protection circuitry must not be relied upon to protect secondary 24VDC
electrical circuits from damage caused by over-current or short circuit. DC
fuses or DC electronic circuit breakers are recommended for full protection.
Allow for access to drivers for maintenance and sufficient clear air space for
ventilation.
CABLING
Do not overload the driver. Damage will be caused by incorrect input
voltage, reverse polarity or short circuit. Plan for loads, driver locations,
dimming and cabling prior to start of work. Ensure basic insulation is
maintained between mains and dimming control wires.
ACCESSORIES
- Cable & Connector VECA-CA0250- MF-R1 2 / 3 / 4 / 5 Pole power link 250mm cable length
- VECA-CA1000- MF-R1 2 / 3 / 4 / 5 Pole power link 1000mm cable length
IDC Connector
VECA-CA90 -R1
Sealant connector.
1-3AMax/3 – 5A Max. Pair
Self-Closing Cable Sleeving
VECA-SL001-R1
1m cable sleeving Easy Mount
V36S-MS402-R1 Mounting clips
1 pair per luminaire Stealth Mount
V36S-MS501-R1
Hidden fixing clip Allow 3 clips per metre Rotation Mount
V36S-MS601-R1 Rotation mount Allow 2 clips per metre
IMV36S_IP64_R2102
CHECK FIRST!
TURN OFF POWER!COUPER LE COURANT!STROM ABSHALTEN!CORTE CORRIENTE!
CHECK THE WALL!VËRIFIER LE MUR!
INSTALLATION
Plan Installation
Check product and its dimensions against the planned installation. Runs of
LEDs may have to be installed in a particular sequence.
105mm – 2005mm length
Prepare Power Supply
This product requires a 24VDC power supply. Please refer to provided wiring
guide document. Failure to follow guide may result in damage to the product
and voiding of warranty.
Cable Exit
Plan cable entry and exit points before installing the product. Make a
suitably sized hole for the cable/s to pass through, and position beneath
where the product is planned to be placed. Mounting Clips
Fix all the clips securely to the mounting surface. Recommended screw size is
no greater than Ø4.00mm in diameter. Use fixings suitable for the material
being fixed into.
Products should be held with equally spaced clips (see accessories for
quantity per metre). Products shorter than 505mm may be held by just 2 clips.
There must always be a clip within 100mm to 200mm of each end of the product.
Connect to LED Driver
With the power off. Feed the power cables to the V36S, connecting the product
to the LED driver. Finalise all electrical connections and test the circuit.
If the product does not function as expected, turn power off immediately and
check all connections.
Mount Product
Align clips and carefully push the product into the clips. Ensure the product
is fully clipped in place and check it is not misaligned or misplaced due to
screw heads or wires. Ensure that cables are not pinched when installed.
Protect exposed cable
Self-closing cable sleeving: VECA-SL001-R1
For outdoor applications, the power cable must be wrapped in cable sleeving to
protect the cable from UV exposure. Trim sleeving to match cable length.
EASY MOUNT INSTALLATION
V36S-MS402-R1
Plan Out Installation
Easy mount fixing orientation should be installed as shown.
Measure and Drill Holes
Plan fixing hole positions, drill pilot holes and cable entry/exit holes as
required.
Make a suitably sized hole for the cable/s to pass through, and position
beneath where the product is planned to be placed. Fix to
Mounting Surface
Fix the easy mount to the fixing surface using a screw fixing appropriate for
the mounting surface. Use a screw no bigger than Ø5mm. Allow for easy mount
to have some movement.
Install V36S
Fit V36S to the easy mounts, making sure not to pinch cables when installing.
Close Latch
Secure V36S to the easy mounts by closing the latch. Check that mounting is
secure.
Removing V36S
To remove, use a plastic pry tool. Following steps 4 and 5 in reverse.
ROTATION MOUNT INSTALLATION
V36S-MS601-R1
Mount Positions
Adjust positions of the mounts against the V36S profile by spacing the mounts
out as shown in the diagram, then tighten screws using the provided Allen key.
Mount the V36S
Fix the V36S to the mounting surface using a screw fixing appropriate for the
mounting surface. Adjust
Adjust the V36S to the desired position and lock of the angle of adjustment
using the provided Allen key. Ensure that all adjustment screws are tightened.
ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of
Regulations (EU) 2019/2020 and (EU) 2019/2015.
The contained light source is an integrated part of the containing product and
its removal can only be done by causing permanent damage to the containing
product. Therefore, replacement of the light source with the use of commonly
available tools is not justified due to its restricted mechanical,
electrical, optical, thermal and/or environmental protection requirements.
DISMANTLING
Dismantling of light source from the containing product at end of life:
The containing product shall be cut to the length of the contained light
source and the light source mechanically detached from the containing product.
Containing product component parts shall then be disassembled.
Containing products shall be separated from building material and/or from
other additional mounting accessories by means of a professional installer.
Separate control gear and light sources must be disposed of at certified
disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU
and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in
the UK.
LUMINO is a member of the WEEE producer compliance scheme. Registration
number: WEE/MM8138AA
ENERGY RATING
This product contains light sources of energy efficiency classes as shown:
LED | CCT | 9.6W/m | 1 2W/m | 24W/m | 30W/m |
---|
ColorCORE
| 4000K| –| F| F| F
3500K| –| F| F| F
3000K| –| F| F| F
2700K| –| F| G| G
2500K| –| F| G| G
2200K| –| F| G| G
EQ
| 4000K| –| F| G| G
3000K| –| G| G| G
2700K| –| G| G| G
ColorTUNE
| 4000K – 2200K| –| –| F| –
3000K – 1800K| –| –| F| –
WarmDIM| 3000K| F| –| –| –
RGBW| RGB + 3000K| –| F| G| –
RGB| N/A