Installers must read this document and any other referenced documents in full before commencing installation work. Failure to observe all installation guidance in this document may result in unsafe installation, cause permanent product damage and void product warranty.
This document is subject to change without notice. Check for latest documentation with LUMINO. Copyright © LUMINO. E&OE

HANDLING PRECAUTIONS

  • PLASTIC COVER / DIFFUSER
    To avoid permanent damage, do not allow small or sharp objects to apply pressure on to the plastic cover / diffuser.

  • IMPACT PROTECTION
    The product is not vandal resistant. Never stand or place weighted items on the product. This product has a maximum IK rating of IK08.

  • POWER CABLES
    The product end caps, power cables and connectors must not be pulled or twisted. Never pull the product by its power cables or hang it from its power cables or connectors.

  • CUTTING AND SAWING
    The product must not be sawn, drilled or otherwise modified in any way.

  • DAMAGES
    Inspect the product. If you see any damage upon unpacking, report to LUMINO immediately and do not install the product.

  • LOCATION
    Suitable for damp locations. IP64 rated product is dust tight and protected against water splashes.
    Protect product from dust, paint and harmful substances during installation and use. Ensure product is not exposed to VOC gases. Do not obstruct the product and its light output.

SAFETY GUIDANCE

WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum cable lengths, cable sizes and other wiring instructions. When running cables through an enclosure, ensure cables are protected from damage, separated from mains voltage cables and anchored against being pulled. Make connections appropriate for the IP rating of the product.

QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in accordance with local regulations and applicable standards.

THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case temperature
(Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause permanent damage and void the product warranty.
Allow sufficient clear air space for the LED drivers, as well as suitable access to the drivers as specified on installation instructions.

REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service Call for factory repair or replacement. Light source is not user replaceable. See page 5 for Eco design and end of life information.

DRIVERS

POWER OFF
Product and driver must not be live wired. Switch off power before work begins. Follow instructions and guidance for the make and model of driver being used.
24VDC SELV
Only use drivers with a maximum output of 24VDC.  Drivers must be SELV, constant voltage with both overload and short-circuit protection.
DIMMERS
Check dimmer is compatible with the driver and certified to local regulations.
INRUSH CURRENT
Many constant voltage LED drivers can have high in rush current at power-on. Driver’s inrush current  can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistent problem an inrush suppressor may be required.
PROTECTION
Use only with 24VDC Class 2 power unit toUL1310 standard with overload and short-circuit protection. Rate drivers for at least 10% above load. Driver protection circuitry must not be relied upon to protect secondary 24VDC electrical circuits from damage caused by over-current or short circuit. DC fuses or DC electronic circuit breakers are  recommended for full protection.
Allow for access to drivers for maintenance and sufficient clear air space for ventilation.
CABLING
Do not overload the driver. Damage will  be caused  by incorrect input voltage, reverse polarity or short circuit. Plan for loads, driver locations, dimming and cabling prior to start of work. Ensure basic insulation is maintained between mains and dimming control wires.

ACCESSORIES

  • Cable & Connector VECA-CA0250- MF-R1 2 / 3 / 4 / 5 Pole power link 250mm cable length
  • VECA-CA1000- MF-R1 2 / 3 / 4 / 5 Pole power link 1000mm cable length

IDC Connector
VECA-CA90 -R1
Sealant connector.
1-3AMax/3 – 5A Max. Pair

Self-Closing Cable Sleeving
VECA-SL001-R1
1m cable sleeving Easy Mount
V36S-MS402-R1 Mounting clips
1 pair per luminaire LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-
Closing Cable Sleeving FIG 5 Stealth Mount
V36S-MS501-R1
Hidden fixing clip Allow 3 clips per metre Rotation Mount
V36S-MS601-R1 Rotation mount Allow 2 clips per metre
IMV36S_IP64_R2102

CHECK FIRST!

TURN OFF POWER!COUPER LE COURANT!STROM ABSHALTEN!CORTE CORRIENTE!

CHECK THE WALL!VËRIFIER LE MUR!

INSTALLATION

Plan Installation
Check product and its dimensions against the planned installation. Runs of LEDs may have to be installed in a particular sequence.
105mm – 2005mm length

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 10

Prepare Power Supply
This product requires a 24VDC power supply. Please refer to provided wiring guide document. Failure to follow guide may result in damage to the product and voiding of warranty.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 11 Cable Exit
Plan cable entry and exit points before installing the product. Make a suitably sized hole for the cable/s to pass through, and position beneath where the product is planned to be placed. LUMINO V36SIP64 Lighting 5
Protect Exposed Cable Self-Closing Cable Sleeving FIG 12Mounting Clips
Fix all the clips securely to the mounting surface. Recommended screw size is no greater than Ø4.00mm in diameter. Use fixings  suitable for the material being fixed into.
Products should be held with equally spaced clips (see accessories for quantity per metre). Products shorter than 505mm may be held by just 2 clips. There must always be a clip within 100mm to 200mm of each end of the product.

Connect to LED Driver
With the power off. Feed the power cables to the V36S, connecting the product to the  LED driver. Finalise all electrical connections and test the circuit. If the product does not function as expected, turn power off immediately and check all connections.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 13 Mount Product
Align clips and carefully push the product into the clips. Ensure the product is fully clipped in place and check it is not misaligned or misplaced due to screw heads or wires. Ensure that cables are not pinched when installed.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 14 Protect exposed cable
Self-closing cable sleeving: VECA-SL001-R1
For outdoor applications, the power cable must be wrapped in cable sleeving to protect the cable from UV exposure. Trim sleeving to match cable length.

EASY MOUNT INSTALLATION

V36S-MS402-R1
Plan Out Installation
Easy mount fixing orientation should be installed as shown.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 16 Measure and Drill Holes
Plan fixing hole positions, drill pilot holes and cable entry/exit holes as required.
Make a suitably sized hole for the cable/s to pass through, and position beneath where the product is planned to be placed. LUMINO V36SIP64 Lighting
5 Protect Exposed Cable Self-Closing Cable Sleeving FIG
17Fix to Mounting Surface
Fix the easy mount to the fixing surface using a screw fixing appropriate for the mounting  surface. Use a screw no bigger than Ø5mm. Allow for easy mount to have some movement.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 18 Install V36S
Fit V36S to the easy mounts, making sure not to pinch cables when installing. LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 19Close Latch
Secure V36S to the easy mounts by closing the latch. Check that mounting is secure.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 20 Removing V36S
To remove, use a plastic pry tool. Following steps 4 and 5 in reverse. LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 21

ROTATION MOUNT INSTALLATION

V36S-MS601-R1
Mount Positions
Adjust positions of the mounts against the V36S profile by spacing the mounts out as shown in the diagram, then tighten screws using the provided Allen key.

LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-Closing Cable Sleeving
FIG 22 Mount the V36S
Fix the V36S to the mounting surface using a screw fixing appropriate for the mounting surface. LUMINO V36SIP64 Lighting 5 Protect Exposed Cable Self-
Closing Cable Sleeving FIG 23Adjust
Adjust the V36S to the desired position and  lock of the angle of adjustment using the provided Allen key. Ensure that all adjustment screws are tightened.

ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of Regulations (EU) 2019/2020 and (EU) 2019/2015.
The contained light source is an integrated part of the containing product and its removal can only be done by causing permanent damage to the containing product. Therefore, replacement of the light source with the use of commonly available tools is not justified due to its restricted  mechanical, electrical, optical, thermal and/or environmental protection requirements.

DISMANTLING
Dismantling of light source from the containing product at end of life:

The containing product shall be cut to the length of the contained light source and the light source mechanically detached from the containing product. Containing product component parts shall then be disassembled.
Containing products shall be separated from building material and/or from other additional mounting accessories by means of a professional installer.

Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK.
LUMINO is a member of the WEEE producer compliance scheme. Registration number: WEE/MM8138AA

ENERGY RATING
This product contains light sources of energy efficiency classes as shown:

LED CCT 9.6W/m 1 2W/m 24W/m 30W/m

ColorCORE

| 4000K| –| F| F| F
3500K| –| F| F| F
3000K| –| F| F| F
2700K| –| F| G| G
2500K| –| F| G| G
2200K| –| F| G| G

EQ

| 4000K| –| F| G| G
3000K| –| G| G| G
2700K| –| G| G| G

ColorTUNE

| 4000K – 2200K| –| –| F| –
3000K – 1800K| –| –| F| –
WarmDIM| 3000K| F| –| –| –
RGBW| RGB + 3000K| –| F| G| –