LUMINO V36S Optic IP64 Optical Light Display Installation Guide
- June 6, 2024
- LUMINO
Table of Contents
V36S OPTIC IP64
INSTALLATION MANUAL
IMV36S_OPTIC_IP64_R2102
**** HANDLING PRECAUTIONS
PLASTIC COVER / DIFFUSER
To avoid permanent damage, do not allow small or sharp objects to apply
pressure on to the plastic cover / diffuser.
IMPACT PROTECTION
The product is not vandal resistant. Never stand or place weighted items on
the product. This product has a maximum IK rating of IK08. POWER CABLES The
product end caps, power cables and connectors must not be pulled or twisted.
Never pull the product by its power cables or hang it from its power cables or
connectors.
CUTTING AND SAWING
The product must not be sawn, drilled or otherwise modified in any way.
DAMAGES Inspect the product. If you see any damage upon unpacking, report to
LUMINO immediately and do not install the product.
LOCATION Suitable for damp locations. IP64 rated product is dust tight and
protected against water splashes. Protect product from dust, paint and harmful
substances during installation and use. Ensure product is not exposed to VOC
gases. Do not obstruct the product and its light output.
**** SAFETY GUIDANCE
WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum
cable lengths, cable sizes and other wiring instructions. When running cables
through an enclosure, ensure cables are protected from damage, separated from
mains voltage cables and anchored against being pulled. Make connections
appropriate for the IP rating of the product.
QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in
accordance with local regulations and applicable standards.
THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case
temperature (Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause
permanent damage and void the product warranty. Allow sufficient clear air
space for the LED drivers, as well as suitable access to the drivers as
specified on installation instructions.
REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service Call
for factory repair or replacement. Light source is not user replaceable. See
page 5 for Ecodesign and end of life information.
DRIVERS
POWER OFF
Product and driver must not be live wired. Switch off power before work
begins. Follow instructions and guidance for the make and model of driver
being used.
CONSTANT CURRENT DC
Ensure supply current does not exceed 350mA or 500mA (see product label).
Drivers must be constant current type with both overload and short-circuit
protection. Exceeding the stated voltage or current will cause permanent
damage and void the product warranty.
DIMMERS
Check dimmer is compatible with the driver and certified to local regulations.
INRUSH CURRENT
Many LED drivers can have high inrush current at power-on. Driver inrush
current can be many times the normal operating current. Use a suitable MCB.
Type C MCBs are normally suitable but if inrush current is a persistent
problem an inrush suppressor may be required.
PROTECTION
Use only with constant current Class 2 power unit to UL1310 standard with
overload and short-circuit protection. Rate drivers for at least 10% above
load. Driver protection circuitry must not be relied upon to protect secondary
electrical circuits from damage caused by over-voltage or short circuit. DC
fuses or DC electronic circuit breakers are recommended for full protection.
Allow for access to drivers for maintenance and sufficient clear air space for
ventilation.
CABLING
Do not overload the driver. Damage will be caused by incorrect input voltage,
reverse polarity or short circuit. Plan for loads, driver locations, dimming
and cabling prior to start of work. Ensure basic insulation is maintained
between mains and dimming control wires.
ACCESSORIES
IDC Connector
VECA-CA90 -R1
Sealant connector.
1 – 3A Max / 3 – 5A Max. Pair| ![LUMINO V36S Optic IP64 Optical Light Display
- Pair](https://manuals.plus/wp-content/uploads/2022/02/LUMINO-V36S-Optic-IP64
-Optical-Light-Display-Pair-300x173.png)| Stealth Mount
V36S-MS501-R1
Hidden fixing clip
Allow 3 clips per metre|
---|---|---|---
Easy Mount
V36S-MS402-R1
Mounting clips
1 pair per luminaire| | Rotation Mount
V36S-MS601-R1
Rotation mount
Allow 2 clips per metre|
CHECK FIRST!
TURN OFF POWER! COUPER LE COURANT! STROM ABSHALTEN! CORTE CORRIENTE!
CHECK THE WALL!
VËRIFIER LE MUR!
DIE WAND ÜBERPRÜFEN!
COMPRUEBE LA PARED!
INSTALLATION
-
Plan Installation
Check product and its dimensions against the planned installation. Runs of LEDs may have to be installed in a particular sequence.
305 / 600 / 900 / 1190mm length
~1714g per metre -
Prepare Power Supply
This product requires a 350mA or 500mA (see product label) constant current power supply. Please refer to the provided wiring guide document. Failure to follow guide may result in damage to the product and voiding of warranty.
-
Cable Exit
Plan cable entry and exit points before installing the product. Make a suitably sized hole for the cable/s to pass through, and position beneath where the product is planned to be placed.
-
Mounting Clips
Fix all the clips securely to the mounting surface. Recommended screw size is no greater than Ø4.00mm in diameter. Use fixings suitable for the material being fixed into.
Products should be held with equally spaced clips (see accessories for quantity per metre).
Products shorter than 505mm may be held by just 2 clips. There must always be a clip within 100mm to 200mm of each end of the product. -
Connect to LED Driver
With the power off. Feed the power cables to the V36S, connecting the product to the LED driver. Finalise all electrical connections and test the circuit. If the product does not function as expected, turn power off immediately and check all connections.♦ Local regulations must be observed.
♦ Do not exceed current rating on product label.
♦ Do not hot-wire the luminaire.
♦ Connection must be IP rated!
Please refer to provided wiring guide document. Failure to follow the provided guide may result in damage to the product and voiding of warranty. -
Mount Product
Align clips and carefully push the product into the clips. Ensure the product is fully clipped in place and check it is not misaligned or misplaced due to screw heads or wires. Ensure that cables are not pinched when installed.
For further help regarding installation visit lumino.lighting
EASY MOUNT INSTALLATION
V36S-MS402-R1
-
Plan Out Installation
Easy mount fixing orientation should be installed as shown.
-
Measure and Drill Holes
Plan fixing hole positions, drill pilot holes and cable entry/exit holes as required.
Make a suitably sized hole for the cable/s to pass through, and position beneath where the product is planned to be placed.
**** Easy mounts spaced 50mm from each end of the luminaire.
-
Fix to Mounting Surface
Fix the easy mount to the fixing surface using a screw fixing appropriate for the mounting surface. Use a screw no bigger than Ø5mm. Allow for easy mount to have some movement.
-
Install V36S
Fit V36S to the easy mounts, making sure not to pinch cables when installing.
-
Close Latch
Secure V36S to the easy mounts by closing the latch. Check that mounting is secure.
Removing V36S
To remove, use a plastic pry tool. Following steps 4 and 5 in reverse.
For further help regarding installation visit lumino.lighting
ROTATION MOUNT
INSTALLATION
V36S-MS601-R1
-
Mount Positions
Adjust positions of the mounts against the V36S profile by spacing the mounts out as shown in the diagram, then tighten screws using the provided Allen key.
-
Mount the V36S
Fix the V36S to the mounting surface using a screw fixing appropriate for the mounting surface.
-
Adjust
Adjust the V36S to the desired position and lock of the angle of adjustment using the provided Allen key. Ensure that all adjustment screws are tightened.
ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of
Regulations (EU) 2019/2020 and (EU) 2019/2015.
The contained light source is an integrated part of the containing product and
its removal can only be done by causing permanent damage to the containing
product.
Therefore, replacement of the light source with the use of commonly available
tools is not justified due to its restricted mechanical, electrical, optical,
thermal and/or environmental protection requirements.
DISMANTLING
Dismantling of light source from the containing product at end of life:
The containing product shall be cut to the length of the contained light
source and the light source mechanically detached from the containing product.
Containing product component parts shall then be disassembled.
Containing products shall be separated from building material and/or from
other additional mounting accessories by means of a professional installer.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK.
LUMINO is a member of the WEEE producer complaince scheme.
Registration number: WEE/MM8138AA
ENERGY RATING
This product contains light sources of energy efficiency classes as shown:
LED | CCT | 60W/m |
---|---|---|
ColorCORE | 4000K | F |
3500K | F | |
3000K | F | |
2700K | F |
CONSTANT CURRENT WIRING GUIDE
LED Driver Wiring
Wiring Diagram
Cable lengths are based on average resistance for typical copper cables. Cable characteristics may vary according to manufacturer, temperature, copper purity, connections etc.
**MAX CABLE DISTANCE***
| DRIVE| 0.3mm²| 0.5mm²| 0.75mm²| 1.0mm²| 16AWG| 2.5mm²
---|---|---|---|---|---|---|---
LED LENGTH| VOLTAGE| WATTAGE| CURRENT| 22AWG| 20AWG| 18AWG| 17AWG| 1.5mm²|
14AWG
0.3m / 1ft
to
2.1m / 7ft| 36V| 12.6W| 350mA| 16m| 25m| 40m| 40m| 40m| 40m
252V| 88.2W| 52ft| 82ft| 131ft| 131ft| 131ft| 131ft
0.3m / 1ft
to
2.1m / 7ft| 36V| 18W| 500mA| 11m| 18m| 29m| 36m| 40m| 40m
252V| 126W| 36ft| 59ft| 95ft| 118ft| 131ft| 131ft
*Observe maximum cable lengths – as shown above or as specified by the driver manufacturer, whichever is the shortest. Longer cable lengths increase EMI susceptibility.
MAX WATTAGE
LED LENGTH | VOLTAGE | 350mA | 500mA |
---|---|---|---|
0.3m / 1ft | 36V | 12.6W | 18W |
0.6m / 2ft | 72V | 25.2W | 36W |
0.9m / 3ft | 108V | 37.8W | 54W |
1.2m / 4ft | 144V | 50.4W | 72W |
1.5m / 5ft | 180V | 63W | 90W |
1.8m / 6ft | 216V | 75.6W | 108W |
2.1m / 7ft | 252V | 88.2W | 126W |
For further help regarding installation visit lumino.lighting
Use appropriate constant current LED drivers (350mA or 500mA, see product
specification) with overload and short-circuit protection. Use reputable driver
manufacturers with appropriate standards for the local requirements.
USA & Canada: Use only with Class 2 power unit to UL1310 standard. Use only
with maximum output 350mA or 500mA (see product specification) Class 2 power
unit.
IM-Constant_Current_CC_R2103
Maximum cable lengths shown above are calculated for voltage drop and do not consider EMI. Long cables can potentially emit EMI. Do not exceed the maximum cable length stated by the driver manufacturer. Installers must ensure EMI emissions do not exceed local regulated limits.
Shielded cables and ferrite coils can be used where applicable.
Installers must ensure voltage drop does not exceed 2%.
Ensure LED driver is disconnected from mains before making any connections.
Polarity is critical and must be observed when making connections.
Constant current LED circuits must be wired in series. Parallel wiring will
not correctly power the LEDs and can potentially cause damage.
Live loading or incorrect polarity connections of LEDs will cause damage and
void the warranty.
Constant current LEDs can have high forward voltages at power-on. LED forward voltage can be significantly be higher than the normal operating voltage of the circuit. Colder temperatures will also increase the forward voltage required to power up the LEDs.
Constant Current LED drivers can also have high inrush current at power-on. Driver inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistent problem an inrush suppressor may be required.
- Installation must be carried out by qualified electrician.
- Electrical work to be conducted in accordance with local regulations.
- Power must be disconnected prior to installation work.
- Ensure free-moving air space around LEDs and drivers.
- Protect the LEDs from dust and paint during installation and use.
- Plan for loads, driver locations, cables sizes etc prior to installation.
- Shielded control pair required for dimming signal wires.
- Incorrect current/voltage, reverse polarity or short circuit will cause damage.
TECHNICAL SUPPORT
+44(0) 1279 635 411
www.lumino.lighting
LUMINO DISTRIBUTION LTD
Lumino House, Lovet Road
Harlow, Essex CM19 5TB
United Kingdom
Installers must read this document and any other referenced documents in full
before commencing installation work.
Failure to observe all installation guidance in this document may result in
unsafe
installation, cause permanent product damage and void product warranty.
This document is subject to change without notice.
Check for latest documentation with LUMINO.
Copyright © LUMINO. E&OE
Read User Manual Online (PDF format)