LUMINO V36R OPTIC IP64 Lighting Installation Guide

June 6, 2024
LUMINO

V36R OPTIC IP64
INSTALLATION MANUAL
IMV36R_OPTIC_IP64_R2102

HANDLING PRECAUTIONS

PLASTIC COVER / DIFFUSER
To avoid permanent damage, do not allow small or sharp objects to apply pressure onto the plastic cover/diffuser.
STRESS
Never stand or place weighted items on the product. The product is not vandal resistant and has no IK rating. Do not subject the product to impact forces.
POWER CABLES
The product end caps, power cables, and connectors must not be pulled or twisted. Never pull the product by its power cables or hang it from its power cables or connectors.
CUTTING AND SAWING
The product must not be sawn, drilled, or otherwise modified in any way.
DAMAGES
Inspect the product. If you see any damage upon unpacking, report to LUMINOX immediately and do not install the product.
LOCATION
Suitable for damp locations. IP64 rated product is dust-tight and protected against water splashes.
Protect products from dust, paint, and harmful substances during installation and use. Ensure the product is not exposed to VOC gases. Do not obstruct the product and its light output.

SAFETY GUIDANCE

WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum cable lengths, cable sizes, and other wiring instructions. When running cables through an enclosure,  ensure cables are protected from damage, separated from mains voltage cables, and anchored against being pulled. Make connections appropriate for the IP rating of the product.

QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in accordance with local regulations and applicable standards.

THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case temperature (Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause permanent damage and void the product warranty.
Allow sufficient clear air space for the LED drivers, as well as suitable access to the drivers as specified on installation instructions.

REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINOX to register a Service Call for factory repair or replacement. The light source is not user-replaceable. See page 4 for codesign and end-of-life information.

DRIVERS

POWER OFF
Product and driver must not be live wired. Switch off the power before work begins. Follow instructions and guidance for the make and model of the driver being used.

CONSTANT CURRENT DC
Ensure supply current does not exceed 350mA or 500mA (see product label). Drivers must be the constant current type with both overload and short-circuit protection.  Exceeding the stated voltage or current will cause permanent damage and void the product warranty.

DIMMERS
Check dimmer is compatible with the driver and certified to local regulations.

INRUSH CURRENT
Many LED drivers can have a high inrush current at power-on. Driver inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistent problem an inrush suppressor may be required.

PROTECTION
Use only with constant current Class 2 power unit to UL1310 standard with overload and short-circuit protection. Rate drivers for at least 10% above load. Driver protection circuitry must not be relied upon to protect secondary electrical circuits from damage caused by over-voltage or short circuits. DC fuses or DC electronic circuit breakers are recommended for full protection. Allow for access to drivers for maintenance and sufficient clear air space for ventilation.

CABLING
Do not overload the driver. Damage will be caused by incorrect input voltage, reverse polarity, or short circuit. Plan for loads, driver locations, dimming, and cabling prior to the start of work. Ensure basic insulation is maintained between mains and dimming control wires.

ACCESSORIES

** IDC Connector**
VECA-CA90 -R1
Sealant connector. 1 – 3A Max / 3 – 5A Max. Pair

CHECK FIRST!

LUMINO V36R OPTIC IP64 Lighting - CHECK FIRSTTURN OFF POWER!
COUPER LE COURANT!
STROM ABSHALTEN!
CORTE CORRIENTE !
CHECK THE WALL!
VËRIFIER LE MUR!
DIE WAND ÜBERPRÜFEN!
COMPRUEBE LA PARED!
IMV36R_OPTIC_IP64_R2102

INSTALLATION

  1. Plan Installation
    Check product and its dimensions against the planned installation.
    Runs of LEDs may have to be installed in a particular sequence.LUMINO V36R
OPTIC IP64 Lighting - Plan Installation

  2. Prepare Power Supply
    This product requires a 350mA or 500mA (see product label) constant current power supply. Please refer to the provided wiring guide document. Failure to follow the guide may result in damage to the product and voiding of the warranty.LUMINO V36R OPTIC IP64 Lighting - Power
Supply

  3. Cut-out Requirements
    Saw cut-out using dimensions below. As shown, add an additional 1mm to the length of the cut-out, with a surface thickness of 12.5mm MIN.

  4. Ceiling Void Requirements
    Observe minimum space requirements behind the product. V36R requires 150mm of clear air around the product and to be 150mm away from the LED driver.LUMINO V36R OPTIC IP64 Lighting - LED driver

  5. Safety Tether
    Secure safety tethers, refer to chart for weights and dimensions.
    Use appropriate fixings and techniques as required by local regulations.LUMINO V36R OPTIC IP64 Lighting - Safety
Tether

Length Cut-out Weight
305mm 40mm x 306mm 0.57 KG
600mm 40mm x 601mm 1.07 KG
900mm 40rnm x 901mm 1.60 KG
1190mm 40mm x 1191mm 2.10 KG
  1. Connect to LED DriverLUMINO V36R OPTIC IP64 Lighting - techniques For further help regarding installation visit lumino. lighting
    With the power off. Feed the power cables to the V36R, connecting the product to the LED driver.LUMINO V36R OPTIC IP64 Lighting - LED
Driver• Local regulations must be observed
    • Do not exceed the current rating on the product label.
    • Do not hot-wire the luminaire.
    Please refer to provided wiring guide document. Failure to follow the provided guide may result in damage to the product and voiding of the warranty.
    IMV36R_OPTIC_IP64_R2102

  2. Install V36R
    Install into the cut-out, applying even pressure.
    Check that the spring clips have engaged, securing the V36R in place.

  3. Clean
    Clean V36R should be cleaned with a soft, dry cloth.

  4. Power Up
    Finalize all electrical connections and test the circuit. If the product does not function as expected, turn the power off immediately and check all connections.

ECODESIGN REGULATION

This product is considered to be a “containing product” in the sense of Regulations (EU) 2019/2020 and (EU) 2019/2015.
The contained light source is an integrated part of the containing product and its removal can only be done by causing permanent damage to the containing product.
Therefore, replacement of the light source with the use of commonly available tools is not justified due to its restricted mechanical, electrical, optical, thermal, and/or environmental protection requirements.

DISMANTLING

Dismantling of the light source from the containing product at end of life:
The containing product shall be cut to the length of the contained light source and the light source mechanically detached from the containing product. Containing product component parts shall then be disassembled.
Containing products shall be separated from building material and/or from other additional mounting accessories by means of a professional installer.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK.
LUMINOX is a member of the WEEE producer compliance scheme. Registration number: WEE/MM8138AA

ENERGY RATING

This product contains light sources of energy efficiency classes as shown:

LED CCT 60W/m
ColorCORE 4000K F
3500K F
3000K F
2700K F

CONSTANT CURRENT WIRING GUIDE

LED Driver Wiring

*Observe maximum cable lengths – as shown above or as specified by the driver manufacturer, whichever is the shortest. Longer cable lengths increase EMI susceptibility

Wiring Diagram

LED LENGTH| VOLTAGE| 350mA|

500mA

---|---|---|---
0.3m / 1ft| 36V| 12.6W| 18W
0.6m / 2ft| 72V| 25.2W| 36W
0.9m / 3ft| 108V| 37.8W| 54W
1.2m / 4ft| 144V| 50.4W| 72W
1.5m / 5ft| 180V| 63W| 90W
1.8m / 6ft| 216V| 75.6W| 108W
2.1m/ 7ft| 252V| 88.2W| 126W

Cable lengths are based on average resistance for typical copper cables. Cable characteristics may vary according to manufacturer, temperature, copper purity, connections, etc.

Use appropriate constant current LED drivers (350mA or 500mA, see product specification) with overload and short-circuit protection. Use reputable driver manufacturers with appropriate standards for the local requirements.

USA & Canada: Use only with Class 2 power unit to UL1310 standard. Use only with maximum output of 350mA or 500mA (see product specification) Class  2 power unit.
IM-Constant_Current_CC_R2103

Maximum cable lengths shown above are calculated for voltage drop and do not consider EMI. Long cables can potentially emit EMI. Do not exceed the maximum cable length stated by the driver manufacturer. Installers must ensure EMI emissions do not exceed local regulated limits.
Shielded cables and ferrite coils can be used where applicable. Installers must ensure voltage drop does not exceed 2%.

Ensure LED driver is disconnected from mains before making any connections.
Polarity is critical and must be observed when making connections.
Constant current LED circuits must be wired in series. Parallel wiring will not correctly power the LEDs and can potentially cause damage.
Live loading or incorrect polarity connections of LEDs will cause damage and void the warranty.

Constant current LEDs can have high forward voltages at power-on. LED forward voltage can be significantly be higher than the normal operating voltage of the circuit. Colder temperatures will also increase the forward voltage required to power up the LEDs.
Constant Current LED drivers can also have a high inrush current at power-on. Driver inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistent problem an inrush suppressor may be required.

  •   Installation must be carried out by a qualified electrician.
  • Electrical work to be conducted in accordance with local regulations.
  • Power must be disconnected prior to installation work.
  • Ensure free-moving air space around LEDs and drivers.
  • Protect the LEDs from dust and paint during installation and use.
  • Plan for loads, driver locations, cables sizes, etc prior to installation.
  • Shielded control pair required for dimming signal wires.
  • Incorrect current/voltage, reverse polarity, or short circuit will cause damage.

TECHNICAL SUPPORT
+44(0) 1279 635 411
www.lumino.lighting
LUMINO DISTRIBUTION LTD
Lumino House, Lovet Road
Harlow, Essex CM19 5TB
United Kingdom

Installers must read this document and any other referenced documents in full before commencing installation work. Failure to observe all installation guidance in this document may result in unsafe installation, cause permanent product damage, and void product warranty.
This document is subject to change without notice. Check for the latest documentation with LUMINO.
Copyright © LUMINO. E&OE

LUMINO V36R OPTIC IP64 Lighting - ICON

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

LUMINO User Manuals

Related Manuals