LUMINO V36R IP64 Lighting Installation Guide

June 6, 2024
LUMINO

LUMINO V36R IP64 Lighting

TECHNICAL SUPPORT
+44(0) 1279 635 411
www.lumino.lighting

LUMINO DISTRIBUTION LTD
Lumino House, Lovet Road
Harlow, Essex CM19 5TB
United Kingdom
Installers must read this document and any other referenced documents in full before commencing installation work. Failure to observe all installation guidance in this document may result in unsafe installation, cause permanent product damage and void product warranty.
This document is subject to change without notice. Check for latest documentation with LUMINO. Copyright © LUMINO. E&OE

HANDLING PRECAUTIONS

  • PLASTIC COVER / DIFFUSER
    To avoid permanent damage, do not allow small or sharp objects to apply pressure on to the plastic cover / diffuser.

  • STRESS
    Never stand or place weighted items on the product. The product is not vandal resistant and has no IK rating. Do not subject the product to impact forces.

  • POWER CABLES
    The product end caps, power cables and connectors must not be pulled or twisted. Never pull the product by its power cables or hang it from its power cables or connectors.

  • CUTTING AND SAWING
    The product must not be sawn, drilled or otherwise modified in any way.

  • DAMAGES
    Inspect the product. If you see any damage upon unpacking, report to LUMINO immediately and do not install the product.

  • LOCATION
    Suitable for damp locations. IP64 rated product is dust tight and protected against water splashes.
    Protect product from dust, paint and harmful substances during installation and use. Ensure product is not exposed to VOC gases. Do not obstruct the product and its light output.

SAFETY GUIDANCE

  • WIRING GUIDE
    Follow the guidance shown in the provided wiring guide, including maximum cable lengths, cable sizes and other wiring instructions. When running cables through an enclosure, ensure cables are protected from damage, separated from mains voltage cables and anchored against being pulled. Make connections appropriate for the IP rating of the product.

  • QUALIFIED INSTALLER
    Installation must be carried out by a qualified person and conducted in accordance with local regulations and applicable standards.

  • THERMAL MANAGEMENT
    Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case temperature (Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause permanent damage and void the product warranty.
    Allow sufficient clear air space for the LED drivers, as well as suitable access to the drivers as specified on installation instructions.

  • REPAIR AND REPLACEMENT
    If the product is not functioning, contact LUMINO to register a Service Call for factory repair or replacement. Light source is not user replaceable. See page 4 for Ecodesign and end of life information.

DRIVERS

  • POWER OFF
    Product and driver must not be live wired. Switch off power before work begins. Follow instructions and guidance for the make and model of driver being used.

  • 24VDC SELV
    Only use drivers with a maximum output of 24VDC. Drivers must be SELV, constant voltage with both overload and short-circuit protection.

  • DIMMERS
    Check dimmer is compatible with the driver and certified to local regulations.

  • INRUSH CURRENT
    Many constant voltage LED drivers can have high inrush current at power-on. Driver’s inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistent problem an inrush suppressor may be required.

  • PROTECTION
    Use only with 24VDC Class 2 power unit to UL1310 standard with overload and short-circuit protection. Rate drivers for at least 10% above load. Driver protection circuitry must not be relied upon to protect secondary 24VDC electrical circuits from damage caused by over-current or short circuit. DC fuses or DC electronic circuit breakers are recommended for full protection.
    Allow for access to drivers for maintenance and sufficient clear air space for ventilation.

  • CABLING
    Do not overload the driver. Damage will be caused by incorrect input voltage, reverse polarity or short circuit. Plan for loads, driver locations, dimming and cabling prior to start of work. Ensure basic insulation is maintained between mains and dimming control wires.

ACCESSORIES

  • Cable & Connector
    VECA-CA0250- MF-R1 2 / 3 / 4 / 5 Pole power link 250mm cable length
    VECA-CA1000- MF-R1 2 / 3 / 4 / 5 Pole power link 1000mm cable length

  • IDC Connector
    VECA-CA90 -R1
    Sealant connector.
    1 – 3A Max / 3 – 5A Max. Pair

LUMINO V36R IP64 Lighting fig 2

CHECK FIRST

TURN OFF POWER! COUPER LE COURANT!STROM ABSHALTEN!CORTE CORRIENTE!

LUMINO V36R IP64 Lighting fig 3

CHECK THE WALL!VËRIFIER LE MUR!
DIE WAND ÜBERPRÜFEN!COMPRUEBE LA PARED!

INSTALLATION

Plan Installation
Check product and its dimensions against the planned installation. Runs of LEDs may have to be installed in a particular sequence.
Prepare Power Supply
This product requires a 24VDC power supply.
Please refer to provided wiring guide document. Failure to follow guide may result in damage to the product and voiding of warranty. Cut-out Requirements
Saw cut-out using dimensions below. As shown, add an additional 1mm to the length of the cut-out, with a surface thickness of 12.5mm MIN.

LUMINO V36R IP64 Lighting fig 7 Ceiling Void Requirements
Observe minimum space requirements behind the product. V36R requires 150mm of clear air around the product and to be 150mm away from the LED driver.

LUMINO V36R IP64 Lighting fig 8 Safety Tether
Secure safety tethers, refer to chart for weights and dimensions.
Use appropriate fixings and techniques as required by local regulations. LUMINO V36R IP64 Lighting fig 9

Length Cut-out Weight
105mm 40mm x 106mm 0.18 KG
205mm 40mm x 206mm 0.30 KG
305mm 40mm x 306mm 0.42 KG
405mm 40mm x 406mm 0.55 KG
505mm 40mm x 506mm 0.67 KG
605mm 40mm x 606mm 0.79 KG
705mm 40mm x 706mm 0.92 KG
805mm 40mm x 806mm 1.04 KG
905mm 40mm x 906mm 1.17 KG
1005mm 40mm x 1006mm 1.29 KG
1105mm 40mm x 1106mm 1.42 KG
1205mm 40mm x 1206mm 1.54 KG
1305mm 40mm x 1306mm 1.66 KG
1405mm 40mm x 1406mm 1.79 KG
1505mm 40mm x 1506mm 1.92 KG
1605mm 40mm x 1606mm 2.04 KG
1705mm 40mm x 1706mm 2.16 KG
1805mm 40mm x 1806mm 2.29 KG
1905mm 40mm x 1906mm 2.41 KG
2005mm 40mm x 2006mm 2.53 KG

Connect to LED Driver
With the power off. Feed the power cables to the V36R, connecting the product to the LED driver.

LUMINO V36R IP64 Lighting fig 10 Install V36R
Install into cut-out, applying even pressure. Check that the spring clips have engaged, securing the V36R in place.

LUMINO V36R IP64 Lighting fig 11 Clean
Clean V36R should be cleaned with a soft, dry cloth. Power Up
Finalize all electrical connections and test the circuit. If the product does not function as expected, turn power off immediately and check all connections. ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of Regulations (EU) 2019/2020 and (EU) 2019/2015.
The contained light source is an integrated part of the containing product and its removal can only be done by causing permanent damage to the containing product.
Therefore, replacement of the light source with the use of commonly available tools is not justified due to its restricted mechanical, electrical, optical, thermal and/or environmental protection requirements.

DISMANTLING
Dismantling of light source from the containing product at end of life:
The containing product shall be cut to the length of the contained light source and the light source mechanically detached from the containing product. Containing product component parts shall then be disassembled.

Containing products shall be separated from building material and/or from other additional mounting accessories by means of a professional installer.
Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and
with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK.
LUMINO is a member of the WEEE producer compliance scheme. Registration number: WEE/MM8138AA

ENERGY RATING

This product contains light sources of energy efficiency classes as shown:

LED CCT 9.6W/m 1 2W/m 24W/m 30W/m
Color CORE 4000K F F F
3500K F F F
3000K F F F
2700K F G G
2500K F G G
2200K F G G
EQ 4000K F G G
3000K G G G
2700K G G G
Color TUNE 4000K – 2200K F
3000K – 1800K F
WarmDIM 3000K F
RGBW RGB + 3000K F G
RGB N/A

For further help regarding installation visit lumino.lighting