HANDLING PRECAUTIONS
GLASS
Take extra care with glass when handling the product. Glass can be chipped, if
hit on the edge against hard objects. Do not apply pressure with small or
sharp objects to the lass. Glass is rated for a walk-over use.
POWER CABLES
The product end caps, power cables, and connectors must not be pulled or
twisted. Never pull the product by its power cables or hang it from its power
cables or connectors.
IMPACT PROTECTION AND STATIC LOAD
This product has a maximum IK rating of IK09 and can resist a maximum 5kN/min
static load. The product is not vandal resistant.
CUTTING AND SAWING
The product must not be cut, sawn, drilled, or otherwise modified in any way.
DAMAGES
Inspect the product and if you see any damage upon unpacking report to LUMINO
immediately and do not install the product
LOCATION
Suitable for wet and damp locations. IP68 rated for temporary submersion. Max
depth. 1.2M / Max duration. 30mins. Ensure there is adequate drainage made
available for the product. Protect product from dust, paint and harmful
substances during installation and use. Ensure the product is not exposed to
VOC gases. Do not obstruct the product and its light output.
SAFETY GUIDANCE
WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum
cable lengths, cable sizes, and other wiring instructions. When running cables
through an enclosure, ensure cables are protected from damage, separated from
mains voltage cables, and anchored against being pulled. Make connections
appropriate for the IP rating of the product.
QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in
accordance with local regulations and applicable standards.
THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case
temperature (Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause
permanent damage and void the product warranty. Allow sufficient clear air
space for the LED drivers, as well as suitable access to the drivers as
specified in installation instructions.
REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service Call
for factory repair or replacement. The light source is not user-replaceable.
See page 4 for Ecodesign and end-of-life information.
DRIVERS
POWER OFF
Product and driver must not be live wired. Switch off the power before work
begins. Follow instructions and guidance for the make and model of the driver
being used.
CONSTANT CURRENT DC
Ensure supply current does not exceed 350mA or 500mA (see product label).
Drivers must be the constant current type with both overload and short-circuit
protection. Exceeding the stated voltage or current will cause permanent
damage and void the product warranty.
DIMMERS
Check dimmer is compatible with the driver and certified to local regulations.
INRUSH CURRENT
Many LED drivers can have high inrush current at power-on. Driver inrush
current can be many times the normal operating current. Use a suitable MCB.
Type C MCBs are normally suitable but if inrush current is a persistent
problem an inrush suppressor may be required.
PROTECTION
Use only with constant current Class 2 power unit to UL1310 standard with
overload and short-circuit protection. Rate drivers for at least 10% above
load. Driver protection circuitry must not be relied upon to protect secondary
electrical circuits from damage caused by over-voltage or short circuit. DC
fuses or DC electronic circuit breakers are recommended for full protection.
Allow for access to drivers for maintenance and sufficient clear air space for
ventilation.
CABLING
Do not overload the driver. Damage will be caused by incorrect input voltage,
reverse polarity, or a short circuit. Plan for loads, driver locations,
dimming, and cabling prior to the start of work. Ensure basic insulation is
maintained between mains and dimming control wires.
ACCESSORIES
Cable VECA-CA010-R1 2 Core 0.75mm² cable 10m cable length
Connector VECA-CA003-R1 2 Pole connector Up to 4 cables
Ground Channel V36G-B2050-R1 2050mm Profile Site cuttable
Ground Channel End Caps V36G-MB202-R1 2pcs end caps
Ground Channel Joining Kit V36G-JB203-R1 Joining kit
Clips V36G-MB201-R1 10pcs clips 4 pairs per meter
Removal Tool V36I-MA204-R1 1pcs tool
**CHECK FIRST!
**
INSTALLATION
Plan Installation
Check product and its dimensions against the planned installation. Runs of
LEDs may have to be installed in a particular sequence.
Prepare Power Supply
This product requires a 350mA or 500mA (see product label) constant current
power supply. Please refer to the provided wiring guide document. Failure to
follow the guidelines may result in damage to the product and voiding of the
warranty.
LED driver must be located somewhere suitable for its IP rating. All connections made to and from the LED driver must be IP rated.
Install Clips
See V36G installation manual for instructions for ground channel installation.
Insert and equally space the retaining clips into the channel. 4 pairs per
meter for a secure hold.
Connect Cable
Connect cables using VECA-CA003-R1 IP68 connector.
- Local regulations must be observed.
- Do not exceed the current rating on the product label.
- Do not hot-wire the luminaire.
Please refer to provided wiring guide document. Failure to follow the provided guide may result in damage to the product and voiding of the warranty
Test V36I
Verify that the circuit is working. Then lower the V36I into the V36G channel.
If the product does not function as expected, turn the power off immediately
and check all connections.
Cables
Make sure not to pinch any cables within the channel. Take care to tuck the
cables beneath the V36G’s internal lip (see diagram).
Silicone
Silicone around the glass edge and the V36G create a good watertight seal and
allow to dry for 6 hours.
Clean
Clean using a glass cleaning cloth and glass cleaning solution. The profile
must be checked every 12 months and cleaned to maintain the warranty.
ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of
Regulations (EU) 2019/202 (EU) 2019/2015. The contained light source is an
integrated part of the containing product and its removal can only be done by
causing permanent
damage to the containing product.
Therefore, replacement of the light source with the use of commonly available
tools is not justified due to its restricted mechanical, electrical, optical,
thermal, and/or environmental protection requirements.
DISMANTLING
Dismantling of the light source from the containing product at end of life: The containing product shall be cut to the length of the contained light source and the light source mechanically detached from the containing product. Containing product component parts shall then be disassembled. Containing products shall be separated from building material and/or from other additional mounting accessories by means of a professional installer. Separate control gear and light sources must be disposed of at certified disposal companies in accordance with Directive2012/19/EU (WEEE) in the EU and with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. LUMINO is a member of the WEEE producer compliance scheme. Registration number: WEE/MM8138AA
ENERGY RATING
This product contains light sources of energy efficiency classes as shown:
LED | CCT | 60W/m |
---|
ColorCORE
| 4000K| F
3500K| F
3000K| F
2700K| F
**LED Driver Wiring
**
Observe maximum cable lengths – as shown above, or as specified by the driver manufacturer, whichever is the shortest. Longer cable lengths increase EMI susceptibility.
**Wiring Diagram
**
Cable lengths are based on average resistance for typical copper cables. Cable
characteristics may vary according to manufacturer, temperature, copper
purity, connections, etc.
For further help regarding installation visit lumino. lighting
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>