LUMINO V36I Optic In-Ground Lighting Profile With Optical Lens Installation Guide

June 6, 2024
LUMINO

LUMINO V36I Optic In-Ground Lighting Profile With Optical Lens

HANDLING PRECAUTIONS

GLASS
Take extra care with glass when handling
the product. Glass can be chipped, if hit on the edge against hard objects. Do not apply pressure with small or sharp objects to the glass. Glass is rated for walk over use.

POWER CABLES
The product end caps, power cables and connectors must not be pulled or twisted. Never pull the product by its power cables or hang it from its power cables or connectors.

IMPACT PROTECTION AND STATIC LOAD
This product has a maximum IK rating of IK09, and can resist a maximum 5kN/min static load. The product is not vandal resistant.

CUTTING AND SAWING
The product must not be cut, sawn, drilled or otherwise modified in any way.

DAMAGES
Inspect the product and if you see any damage upon unpacking report to LUMINO immediately and do not install the product.

LOCATION
Suitable for wet and damp locations. IP68 rated for temporary submersion. Max depth. 1.2M / Max duration. 30mins. Ensure there is adequate drainage made available for the product. Protect product from dust, paint and harmful substances during installation and use. Ensure product is not exposed to VOC gases. Do not obstruct the product and its light output.

SAFETY GUIDANCE

WIRING GUIDE
Follow the guidance shown in the provided wiring guide, including maximum cable lengths, cable sizes and other wiring instructions. When running cables through an enclosure, ensure cables are protected from damage, separated from mains voltage cables and anchored against being pulled. Make connections appropriate for the IP rating of the product.

QUALIFIED INSTALLER
Installation must be carried out by a qualified person and conducted in accordance with local regulations and applicable standards.

THERMAL MANAGEMENT
Ensure ambient temperature (Ta) does not exceed 40°C (104°F) and case temperature (Tc) does not exceed 70°C (158°F). Exceeding maximum Tc will cause permanent damage and void the product warranty. Allow sufficient clear air space for the LED drivers, as well as suitable access to the drivers as specified on installation instructions.

REPAIR AND REPLACEMENT
If the product is not functioning, contact LUMINO to register a Service Call for factory repair or replacement. Light source is not user replaceable. See page 4 for Ecodesign and end of life information.

DRIVERS

POWER OFF
Product and driver must not be live wired. Switch off power before work begins. Follow instructions and guidance for the make and model of driver being used.

24VDC SELV
Only use drivers with a maximum output of 24VDC. Drivers must be SELV, constant voltage with both overload and short-circuit protection.

DIMMERS
Check dimmer is compatible with the driver and certified to local regulations.

INRUSH CURRENT
Many constant voltage LED drivers can have high inrush current at power-on. Driver’s inrush current can be many times the normal operating current. Use a suitable MCB. Type C MCBs are normally suitable but if inrush current is a persistent problem an inrush suppressor may be required.

PROTECTION
Use only with 24VDC Class 2 power unit to UL1310 standard with overload and short-circuit protection. Rate drivers for at least 10% above load. Driver protection circuitry must not be relied upon to protect secondary 24VDC electrical circuits from damage caused by over-current or short circuit. DC fuses or DC electronic circuit breakers are recommended for full protection. Allow for access to drivers for maintenance and sufficient clear air space for ventilation.

CABLING
Do not overload the driver. Damage will be caused by incorrect input voltage, reverse polarity or short circuit. Plan for loads, driver locations, dimming and cabling prior to start of work. Ensure basic insulation is maintained between mains and dimming control wires.

ACCESSORIES

Cable & Connector
VECA-CA8102-R1 Power link cable 2m cable length VECA-CA8110-R1 Power link cable 10mm cable length

LUMINO V36I Optic In-Ground Lighting Profile With Optical Lens
fig2

Ground Channel

  • V36G-B2050-R1
  • 2050mm Profile
  • Site cuttable

Ground Channel End Caps

  • V36G-MB202-R1
  • 2pcs end caps

Ground Channel Joining Kit

  • V36G-JB203-R1
  • Joining kit

Clips

  • V36G-MB201-R1
  • 10pcs clips
  • 4 pairs per metre

Removal Tool

  • V36I-MA204-R1
  • 1pcs tool

CHECK FIRST!

LUMINO V36I Optic In-Ground Lighting Profile With Optical Lens
fig8

INSTALLATION

Plan Installation
Check product and its dimensions against the planned installation. Runs of LEDs may have to be installed in a particular sequence.

Prepare Power Supply
This product requires a 24VDC power supply. Please refer to the provided wiring guide document. Failure to follow guide may result in damage to the product and voiding of warranty.

LED driver must be located somewhere suitable for its IP rating. All connections made to and from the LED driver must be IP rated.

Install Clips
See V36G installation manual for instructions for ground channel installation. Insert and equally space the retaining clips into the channel. 4 pairs per metre for a secure hold.

Connect Cable
Connect first fix cable to the provided IP rated connector. Follow terminal layout as shown below.

  • Local regulations must be observed.
  • Do NOT exceed 3A per serial circuit run.
  • Use only Class 2 Power Unit and install as per driver recommendations.
  • See Vector Wiring Guide for detailed electrical instructions.

Connect V36I
Confirm that the LED driver is disconnected from mains before joining the first fix connector to the V36I’s connector.
Attach any other additional power cables (VECA-CA8102-R1 or VECA-CA8110-R1) and products as well.

LUMINO V36I Optic In-Ground Lighting Profile With Optical Lens
fig13

Test V36I
Verify that the circuit is working. Then lower the V36I into the V36G channel.

If the product does not function as expected, turn power off immediately and check all connections.

Cables
Make sure not to pinch any cables within the channel. Take care to tuck the cables beneath the V36G’s internal lip (see diagram).

Silicone
Silicone around the glass edge and the V36G creating a good watertight seal and allow to dry for 6 hours.

LUMINO V36I Optic In-Ground Lighting Profile With Optical Lens
fig16

Clean
Clean using a glass cleaning cloth and glass cleaning solution. The profile must be checked every 12 months and cleaned to maintain warranty.

ECODESIGN REGULATION
This product is considered to be a “containing product” in the sense of Regulations (EU) 2019/2020 and (EU) 2019/2015. The contained light source is an integrated part of the containing product and its removal can only be done by causing permanent damage to the containing product. Therefore, replacement of the light source with the use of commonly available tools is not justified due to its restricted mechanical, electrical, optical, thermal and/or environmental protection requirements.

DISMANTLING
Dismantling of light source from the containing product at end of life: The containing product shall be cut to the length of the contained light source and the light source mechanically detached from the containing product. Containing product component parts shall then be disassembled. Containing products shall be separated from building material and/or from other additional mounting accessories by means of a professional installer. Separate control gear and light sources
must be disposed of at certified disposal companies in accordance with Directive 2012/19/EU (WEEE) in the EU and
with Waste Electrical and Electronic Equipment (WEEE) Regulations 2013 in the UK. LUMINO is a member of the WEEE producer complaince scheme. Registration number: WEE/MM8138AA

ENERGY RATING

This product contains light sources of energy efficiency classes as shown:

LED CCT 9.6W/m 12W/m 24W/m 30W/m

ColorCORE

| 4000K| –| F| F| F
3500K| –| F| F| F
3000K| –| F| F| F
2700K| –| F| G| G
2500K| –| F| G| G
2200K| –| F| G| G

EQ

| 4000K| –| F| G| G
3000K| –| G| G| G
2700K| –| G| G| G

ColorTUNE

| 4000K – 2200K| –| –| F| –
3000K – 1800K| –| –| F| –
WarmDIM| 3000K| F| –| –| –
RGBW| RGB + 3000K| –| F| G| –
RGB| N/A