BEGA 84979 Gobo Floodlight RGBW Instruction Manual
- June 21, 2024
- BEGA
Table of Contents
Technical amendments reserved
84979
Gobo floodlight RGBW
84979 Gobo Floodlight RGBW
Instructions for use
Application
RGBW floodlight with G½ threaded connection for the projection of Gobo motifs.
Suitable for Gobo motifs in accordance with Rosco default size E.
The floodlight can be controlled by DALI colour light control (DT8, RGBWAF,
xy).
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Clear safety glass
Projector lens with adjustable glass lenses.
Suitable for Gobos with an outer diameter of 37.5 mm, a max. image diameter of
28 mm and a material thickness of max. 1 mm
Rotation range of floodlight 350°
Swivel range -20°/+100°
Mounting bracket with G½ threaded connection
Thread length: 11 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable (DT8, RGBWAF, xy)
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control ®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Safety mark
– Conformity mark
Wind catching area: 0.04 m²
Weight: 2.8 kg
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Installation
LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during
installation or relamping.
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch B, C).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screws (wrench size 2 mm).The electrical connection must be carried out with
matching protection class and safety class, strain-relieved, with suitable
connection terminals (not included in the scope of delivery) at the luminaire
power supply cable.
Observe the correct configuration of the connecting cable. Make the mains
connection to the brown (L), blue (N) and green-yellow wires ( ).
The control cables are connected via the two DALI-labelled wires white-red
(wh-rd) and white-black (wh-bl). If these wires are not assigned, the
luminaire will work with full lightoutput.
Inserting a Gobo
Open the floodlight:
Loosen the locking pin (hexagon socket wrench SW 2.5) on the back of the
floodlight housing.
Turn the lens cover clockwise and lift it off.
To insert a gobo, adjust the knurled screw R4 of the gobo holder so that it is
in line with the knurled screw R3 below it.
Loosen the three knurled screws R3, turn the lens cylinder clockwise to the
stop and lift it off.
Remove the retaining ring on the Gobo receptacle and insert the Gobo. Make
sure to insert the motif inverted and upside down.
Align the Gobo according to the subsequent floodlight position.
Exact alignment is possible in the mounted position via knurled screw R4
within a range of ± 22.5°.
Insert the retaining ring (note the locking lugs) and replace the lens
cylinder, turn it clockwise as far as it will go and tighten the three knurled
screws R3 hand-tight.
The desiccant
pouch provided in the delivery must be placed inside the luminaire to ensure
max. service life of the electrical components. Remove the desiccant pouch
from the foil packaging and place it in the position marked by the red
information label immediately before finally closing the luminaire.
Position the lens cover on the floodlight housing so that the notches in the
floodlight housing and the lens cover are congruent.
Screw on the lens cover clockwise until the stop.
Screw on the locking pin (hexagon socket wrench size 2.5) on the back of the
floodlight housing.
Gobo motifs
Gobos made of metal or glass for insertion into the luminaires are not part of
the scope of delivery.
You can find or individually order a large selection of Gobo motifs or have
them customised to your specifications in the corresponding sizes at
www.emea.rosco.com.When placing an order, please
enter the BEGA article number 84 979 as a reference.
For Gobo masks with text or logos, we recommend a maximum image width of 24
mm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Lamp
Module connected wattage | 15.6 W |
---|---|
Luminaire connected wattage | 18 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 35 °C |
Module designation | LED-1265/RGBW |
Colour temperature of the white LED | 4000 K |
Luminaire luminous flux | 168 lm |
Luminaire luminous efficiency | 9,3 lm / W |
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system.
Loosen the locking pin (hexagon socket wrench SW 2.5) on the back of the
floodlight housing.
Turn the lens cover clockwise and lift it off.
Undo the 4 mounting screws of the lens unit (Torx drive T20) and remove the
complete lens unit.
Replace LED module.
Please follow the installation instructions for the LED module.
Replace and secure the lens unit.
Switch on the floodlight, check the Gobo motif size and focus, and adjust as
needed.
Position the lens cover on the floodlight
housing so that the notches in the floodlight
housing and the lens cover are congruent.
Srew on the lens cover clockwise until the stop.
Screw in the locking pin.
Accessories
70 214 | Pole cap for pole top ø 48 mm |
---|---|
70 248 | Pole cap for pole top ø 60 mm |
70 249 | Pole cap for pole top ø 76 mm |
70 229 | Pole cap for pole top ø 82 mm |
71 042 | Adapter for installation on a pole |
70 379 | Cross beam |
70 221 | Mounting box for anchorage unit |
70 217 | Mounting box ø 110 mm |
70 294 | Mounting box ø 130 mm |
70 284 | Mounting box ø 150 mm |
70 245 | Mounting box · rectangular |
For the accessories a separate instructions for use can be provided upon request.
Spares
Shield ø 20 mm | 16 006 501 |
---|---|
Shield ø 30 mm | 16 006 502 |
Lens cover graphite | 25 000 165 |
Lens cover silver | 25 000 166 |
LED power supply unit | DEV-0418/225i |
LED module | LED-1265/RGBW |
Gasket housing | 83 000 521 |
Gasket Lens cover | 83 001 952 |
EGA Gantenbrink-Leuchten KG
Postfach 31 60
58689 Menden
info@bega.com
www.bega.com