COOPER WSL Series 4WSL-LD2-U Metalux End Access LED Light Instruction Manual
- June 5, 2024
- Cooper
Table of Contents
COOPER WSL Series 4WSL-LD2-U Metalux End Access LED Light
IMPORTANT: Read carefully before installing the fixture. Failure to comply with these instructions may result in death, serious bodily injury, and property damage. Retain for future reference.
WARNING
- Risk of Fire, Electrical Shock, Cuts, or other Casualty Hazards- Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved.
- Risk of Fire and Electric Shock- Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at fuse or circuit breaker.
- Risk of Fire- Minimum 90°C supply conductors.
- Risk of Burn- Disconnect power and allow the fixture to cool before handling or servicing.
- Risk of Personal Injury- Due to sharp edges, handle with care.
DISCLAIMER OF LIABILITY: Cooper Lighting Solutions assumes no liability for
damages or losses of any kind that may
arise from the improper, careless, or negligent installation, handling, or use
of this product.
NOTICE
- Green ground screw provided in the proper location. Do not relocate.
- The fixture may become damaged and/or unstable if not installed properly.
Note: Specifications and dimensions are subject to change without notice.
ATTENTION Receiving Department: Note the actual fixture description of
any shortage or noticeable damage on the delivery receipt. File claim for
common carrier (LTL) directly with the carrier. Claims for concealed damage
must be filed within 15 days of delivery. All damaged material, complete with
original packing must be retained.
INSTALLATION
- Bend end piece to allow wiring into the fixture. (Figure1.)
- Insert Junction box lower half into the fixture. (Figure 2.)
- Secure Junction box lower half using screws provided. (Figure 3.)
- Assemble Junction box upper half and Conduit fitting. (Figure 4.)
- Slide in Junction box upper half to channel. (Figure 5.)
- Secure Junction box upper half using screws provided. (Figure 6.)
- Install cover and waveguide according to standard fixture installation.
- Install Endcap to fixture. Tuck wire harnesses and safety cable while installing. Endcap tabs must fully engage in the metal bracket. (Figure 8.) Wire connection between.
Wire connection between WAB-Econ sensor to Driver
- A sensor attached to the end plate with wires & P-Nuts
- Do connect respective wires from sensor to driver as per below wiring diagram. Refer the table for more details.
DRIVER | SENSOR | WIRE COLOR |
---|---|---|
DIM+ | D | VIOLET |
DIM- | GROUND | PINK |
AUX- | YELLOW | |
AUX+ | + | BROWN |
Warranties and Limitation of Liability
- Please refer to www.eaton.com/LightingWarrantyTerms for our terms and conditions.