LEV3-CH Chrome and Brushed Nickel Tap
“`html
Specifications:
- Model Codes: LEV3/CH & LEV3/BN
- Customer Care Helpline: 0117 938 1900
- Maximum Pressure: 5 bar
Product Usage Instructions:
Installation Instructions:
-
Turn the spout and body so the tap is facing forwards, with the
hot water connection on the left. -
Flush hot and cold pipes to remove debris.
-
A 35mm hole is required in the sink or worktop.
-
Screw the fixing bolt into the tap base without damaging the
threads. -
Place the nylon washer over the fixing bolt flush to the
bottom.
Care of Your Taps:
-
Use soap or mild liquid detergent with clean water to clean
taps, then dry with a soft cloth. -
Avoid chemical cleaners or bleach-based solutions as they can
affect the finish. -
Avoid abrasive cleaners, liquids, powders, or pads to prevent
damage to the tap finish.
Pre-Installation Checks:
-
Ensure hot water supply temperature does not vary, with a
maximum pressure of 5 bar. -
Seek advice from a qualified installer for proper
installation.
Post-Installation Points:
-
Use PTFE tape on screw connections before fully tightening
joints. -
Check for leaks before use and flush hot and cold water to
remove dislodged particles.
These instructions are intended as a guide. If in any doubt,
seek advice from a certified plumber.
FAQ:
Q: How long is the guarantee for the Caple tap?
A: The Caple tap is guaranteed for 5 years from
the date of purchase. Defective products or parts will be repaired,
replaced, or refunded within this period.
Q: What should I do if I encounter any defects during the
guarantee period?
A: Immediately inform us in writing with
details of the defect. Keep a proof of purchase to facilitate your
guarantee claim.
“`
CHROME AND BRUSHED NICKEL TAP CARE, INSTALLATION AND GUARANTEE INFORMATION
MODEL CODES: LEV3/CH & LEV3/BN
Customer care helpline: 0117 938 1900 www.caple.co.uk
IINNSSTTAALLLALATITOINONGUGIDUEIDE
TThhaannkkyoyuouforfoprurpcuharcsihnagsyinougr yCoauprleCtaapp.le tap. d to
exTaThchetesinseegtatspatsaphnsadhvaaervdbeesebanenmednaanmruefaagnctuurfraencdtauendrdedtionasgpneidvcetiendsptoeecxtaecdtitnog
estxaancdtainrdgs astnadnadreargdusaraanndteaedretogguirvaenyteeadrstoof
gtriovueble and
insfyrteeaeallroasptoieorfanttirgoounuipbdrleoelvinifdreeinseghooapuvrecraabrteeioeanndfporinlolsovtiwadlleiandtgi.onougur
icdaelrieneasnhdavine sbteaelnlaftoiollonwgeudi.delines have been followed.
a
Ga caple Ga caple
5 bar
7Q° C
+ S/LCERVU35/C/PHTR S/LCERVU3/5B/NCH S/CRU5/AB
-22
-28
c@)-21 c::::i,-23
6-65- —
54- – CI 4-CI
2223- – 2265- – — 19 22 21- 2 1 — 2528 24- 247- [D 1
[D
LEV3/CH LEV3/BN
ctions NNOOTTEE: :PlPealeseasseeesbeaeckbpaacgke
pfoarginestfaollartiinonstianslltarutciotionnsinstructions
2 INSTALLATION GUIDE LEV3/CH + LEV3/BN Please keep this instruction manual for
future reference
a
6-5-
4-CI
-19 22- 23-
211
24-[D
-25
a
Please keep this instruction manual for future reference INSTALLATION GUIDE
LEV3/CH + LEV3/BN 3
INSTALLATION INSTRUCTIONS
– Turn the spout and body so the tap is facing forwards, the screw on the
spout indicates the rear of the body. The hot water connection should be on
the left of the tap.
– Ensurethehotandcoldpipesarethoroughlyflushedtoremove any debris.
– A 35mm hole is required in either the sink or worktop. –
Thefixingboltmustbescrewedintothetapbase,ensuringthe
threads of the bolt are not damaged in the process. –
Passthenylonwasheroverthefixingboltflushtothebottom
of the tap base, then pass the bolt through the sink or worktop (ensuring the
nylon washer remains directly under the tap base). – Pass the rubber washer
and then the metal washer (on the
undersideofthesink/worktop)overthefixingboltandfixusing thefixingnut. –
Screwtheflexi-tailpipesintothebaseofthetap,ensuringthe
pipesthreadsarenotdamagedintheprocess.Iftheflexi-tails are already inserted
into the tap base, please ensure these are screwed in tightly to prevent any
leaks. – Finallyconnecttheflexi-tailpipestothehotandcoldsupplies ensuring they
are connected to the correct supplies.
CARE OF YOUR TAPS
– Only clean your taps with soap or mild liquid detergent and clean water then
dry using a soft cloth
– Do not use chemical cleaners, or bleach based
solutionstocleanyourtap,contactcouldaffectthefinishof your tap.
– Do not use abrasive cleaners, liquids, powders or pads. These
willdamagethefinishofyourtapandvoidtheguarantee.
– Provided all of the above points are adhered to the surface
finishofyourCapleTapisguaranteedfor5years.
PRE INSTALLATION CHECKS – The temperature of the hot water supply must not
exceed 70°C. – Water pressure requirements: minimum required pressure
varies dependent on model, maximum pressure 5 bar. –
Alwaysseekadvicefromaqualifiedinstallertoensureyour
installation and water supply to your taps comply with the water regulation
(WRAS) requirements and good plumbing practice. – It is good practice to
ensure that both hot and cold water supplies to your tap are of an equal
pressure to provide a consistentflow.Ifsuppliesarenotofequalpressurethena
nonreturnvalveshouldbefittedonthehotinlet. – Supplies of water should be from
a common source (mains or tank fed). – We recommend that a service valve is
installed in the supply lines to the tap to enable water isolation if
required.
POST INSTALLATION POINTS – We suggest when connecting screw connections that
PTFE tape
is used before the joints are fully tightened. – Before use correctly check
the installation for leaks, and
turnthehotandcoldwaterontothoroughlyflushany small particles that may have
been dislodged during the tap installation.
THESE INSTRUCTIONS ARE INTENDED AS A GUIDE,
IF IN ANY DOUBT ENSURE YOU SEEK ADVICE
FROM A CERTIFIED PLUMBER.
GUARANTEE – Your Caple tap is guaranteed for 5 years. – Should you have any
defects as detailed above during the appropriate guarantee period we guarantee
to repair or replace
the defective products or parts, or, at our option refund the purchase price
assuming we were advised immediately of any claim in writing. – It is
important that you keep a proof of purchase (such as your receipt) to
facilitate your guarantee.
TERMS AND CONDITIONS – Guarantee conditions are only valid if the Care
guidelines listed above are followed. – Our obligation under the guarantee is
to the original purchaser, and may not be transferred. – The guarantee is
valid for UK domestic installations only and relates to defects in
manufacture, materials and
workmanship only. – Issues that arise due to normal wear and tear (for example
valves, discs or washers), poor installation,
improper use or accidental damage are not covered by the Caple guarantee.
Spare parts can be purchased from our Customer care helpline 0117 938 1900. –
Noliabilityisacceptedforconsequentialdamagetootherhouseholdfixtures,fittingsorfurnishingsrelating
toanyclaim-evenifattachedtotheproduct. – If it is more economically viable a
replacement tap will be supplied, this tap might vary from the original design
should range changes of occurred since the initial supply. – We reserve the
right to inspect any tap before committing to support under the guarantee
conditions.
4 INSTALLATION GUIDE LEV3/CH + LEV3/BN Please keep this instruction manual for
future reference
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>