Thank you for purchasing Linke products. To ensure a better shopping experience, please follow the instructions for use step by step.

If you have any questions about our products, please contact our customer service, our after-sales team will contact you at the first time and resolve any problems about the products.

Email: linkebsservice@163.com | service @linke-ledlight.com

Warning

  1. The LED module can’t be replaced, you need to replace the entire lamp if it damaged or reach the service life.
  2. If the wire is damaged, the lamp can no longer be used and needs to be scrapped.
  3. If the casing breaks or water enters, the lamp can no longer be used and needs to be scrapped.
  4. Do not stare at the LED light-emitting surface closely for a long time, to prevent the hurt of the eye.
  5. Under no circumstances should the luminaire be covered by a thermal pad or similar material.
  6. The Lamp requires professional electrician to install.
  7. The IP66 waterproof grade is just for rainproof, the lamp can not be immersed in water, otherwise it may cause leakage.
  8. The terminal block is not included. (Please prepare the terminal block according to your actual needs)

Dimension

Component and structure diagrams

Parameter

Model Power Lumen Lighting Range Installation Height A B
Shell Input Lead Shell Input Lead
FLB010 10W 850 3-4M 2.5-3.SM Aluminum L/N/
FLB015 15W 1200 3-4M 2.5-3.SM Aluminum L/N/
FLB020 20W 1700 3-4M 3.0-5.0M Aluminum L/N/
FLB025 25W 2100 3-4M 3.0-5.0M Aluminum L/N/
FLB030 30W 2600 4-6M 3.5-5.0M Aluminum L/N/
FLB035 35W 3000 4-6M 3.5-5.0M Aluminum L/N/
FLB050 SOW 4300 6-8M 5.0-7.0M Aluminum L/N/
FLB054 54W 4700 6-8M 5.0-7.0M Aluminum L/N/
FLB060 60W 5200 6-BM 5.0- 7.0M Aluminum L/N/

N
FLB100| 100W| 9000| 10-12M| 5.0-7.0M| Aluminum| L/N/| Plastic-clad aluminum| LI N

Input voltag e: US : AC 120V/60HZ EU / UK : AC 23 0V/50HZ

Color temp e ratur e: 2700K-6500K
CRI : >70
IP ra t ing : IP66
Ta : -25~40’C

How to Install

Step 1: Drill two mounting holes according to the distance of the screw holes on the bracket.

How to Install

Step 2: Put expansion screws in the prepared mounting holes, then place the bracket in the mounting position and fix with screws.

How to Install

Step 3: Adjust the direction of light and the inspection range of the sensor as needed.

Step 4: Connect the wires.

Step 5: Adjust the TIME, LUX switch at the bottom of the sensor according to actual needs. (Please confirm which sensor you purchased, and then adjust it according to the instructions)

How to Install

Lighting Time Switch: Press the switch 10S-45S-120S-600S cycle.

The indicator light will stay on when switch to corresponding mode.

Working Mode Switch: Press the switch Sun-24H-Moon cycle.

Day mode: Lights up during the day and night, 24 hours working.

24H: Manual Override Mode: Keep staying on, need to power off by the main power. (unaffected by sensor)

Night Mode: Only work at night.

***** The indicator light will stay on when switch to corresponding mode.

Lighting lime Switch: Press the switch 10S-45S-120S-600S cycle.

  • The indicator light will stay on when switch to corresponding mode.

Working Mode Switch: Press the switch Sun-Moon cycle.

Day mode: Lights up during the day and night, 24 hours working.

Night Mode: Only work at night.

***** The indicator light will stay on when switch to corresponding mode.

Note: Day mode: lights up during the day and night, that is, working 24 hours
Night mode: work only at night

Notification

The detection distance depends on the ambient temperature. If the ambient temperature is close to or higher than the human body temperature, the sensing detection distance will become shorter.

This means you need to get closer to this light. Conversely, if the ambient temperature is lower than the human body temperature, this sensing detection distance will be farther.

Routine maintenance

  1. To ensure better lighting, please clean the fixtures regularly.
  2. Before maintenance, make sure the power is disconnected.
  3. To avoid damage of the lamp, please do not clean it with chemicals.

Customer Support

Symbols

Company name: Shenzhen Oumeike Lighting Technology Co., Ltd.

Address: No.19-20,Anye Road, Yuanshan Street, Longgang District, Shenzhen, Guangdong, China ( +86 0755-28608199)

C & E Connection E-Commerce (DE) GmbH Zurn Linnegraben 20, 65933, Frankfurt am Main, Germany
E-mail: info@ce-connection.de Tel: +49 (069) 27246648

CET PRODUCT SERVICE LTD.
Beacon House Stokenchurch Business Park, lbstone Rd, Stokenchurch High Wycombe HP14 3FE UK UK REP
Tel: +447419325266 E-mail: info@cetproduct.com

http://www.linke-ledlight.com

E-mail: linkebsservice@163.com

E-mail: service@linke-ledlight.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals