SDC ED4200 Corbin Russwin Electric Latch Retraction Kit
INSTALLATION
Retrofit Installation Note: 42″ or 48″ exit devices that have been
modified to fit a 36″ or smaller opening, may not have the required space to
fit the standard E. L. R. assembly. Always verify the distance from the end of
the touchpad to the end rail, and if necessary, consult with the factory for
appropriate selection.
Remove the End Cap, Mounting Plate, Cover, Cover Plug, Rail Housing and
Dogging.
Replace Housing Cover, Cover with Plug, End Cap and the End Cap Cover.
When retrofitting to existing vertical rod devices, adjustment of the rods is required for proper operation of the Electric Latch Retractor. Once the unit is properly installed, energize it so the latch is dogged down, then reconnect the vertical rods to the device and make the proper adjustments.