SDC ACM-1 Six Input Control Relays Instructions

June 1, 2024
SDC

SDC ACM-1 Six Input Control Relays

SDC-ACM-1-Six-Input-Control-Relays-FIG- \(2\)

Product Information

Specifications

  • Input: Six Input Control Relays
  • Input Current (Max): Not specified
  • Input Configuration: (3) N/O, Dry; (3) N/C, Dry; (1) SPDT, Wet; (1) SPDT, Dry
  • Dimensions: Not specified
  • Contact Output Configuration: (4) N/O, Dry; (4) SPDT, Fused, Wet or Dry; (4) SPDT, Unfused, Wet or Dry

Product Usage Instructions

Installation

  1. Identify the power supply requirements for your specific setup.
  2. Mount the ACM-1 Six Input Control Relay in a suitable location near the access hardware components.
  3. Connect the input wires according to the specified input configuration.
  4. Verify proper wiring and connections before applying power.

Operation

  1. Use up to six activation devices to control a single electrified locking device.
  2. Monitor the LED visual status indicators for relay activation status.
  3. Troubleshoot any issues by referring to the user manual for guidance.

How to Order

To order the ACM-1 Six Input Control Relay, follow these steps:

  1. Specify model ACM-1 Six Input Control Relay.
  2. Ordering Example: 1 ACM-1
  3. Follow the steps for ordering as indicated in the manual.

FAQ

Q: How many activation devices can be used with the ACM-1?
A: You can control a single lock with up to six activation devices using the ACM-1.

Door control relay modules ensure compatibility of access hardware components and simplify system installation and troubleshooting. Modules may be ordered with or without power supplies. Different modules may be specified for one power supply.
SDC’s ACM-1 series allows for control of a single electrified locking device from up to six activation devices. LED visual status indicators provide relay activation status.

MODELS
ACM-1 Six Input Control Relay

STANDARD FEATURES

  • Six trigger inputs
  • Field selectable dual voltage
  • Visual status indicators (LED)

APPLICATIONS

Control one lock with up to six activation devices.

CROSS-REFERENCE

SDC-ACM-1-Six-Input-Control-Relays-FIG-
\(3\)

SPECIFICATIONS

SDC-ACM-1-Six-Input-Control-Relays-FIG-
\(4\)

HOW TO ORDER

FOLLOW STEPS FOR ORDERING
Designates optional step

SPECIFY MODEL
ACM-1 Six Input Control Relay

  • STEP NUMBER: 1
  • ORDERING EXAMPLE: ACM-1

© 2024 Security Door Controls the lock behind the system