Retrofit Installation Note:
42″ or 48″ exit devices that have been modified to fit a 36″ or smaller opening, may not have the required space to fit the standard E. L. R. assembly. Always verify the distance from the end of the touchpad to the end rail, and if necessary, consult with the factory for appropriate selection.
Remove and discard dogging from device. Slide the Electric Latch Retraction
assembly into device and attach the linkage to the latch retraction rod (short
linkage for standard, long linkage for 4′ device).
ELECTRICAL DATA
24VDC @ 700/200mA
RED (+) BLK (-)
PATENT #8,851,530
Carefully slide the assembly back out until the linkage JUST makes contact
with the latch retraction rod. Tighten set screws.
NOTE Retro-Fitting Vertical Rod Devices
Before retro-fitting an electric latch assembly into a vertical device, the
following must be done to ensure proper alignment. Disconnect the vertical
rods from the device. Install the electric latch assembly as shown above. Once
the ELR is properly installed energize it so that the push pad is dogged down,
by doing so it will allow for proper alignment for the vertical rods. Finally
reconnect the vertical rods to the device and make the proper adjusments.