SDC LR100IDCK-EM Electric Latch Retraction Device Kit Installation Guide

October 27, 2023
SDC

SDC LR100IDCK-EM Electric Latch Retraction Device Kit

INSTALLATION INSTRUCTIONS

Retrofit Installation Note: 42″ or 48″ exit devices that have been modified to fit a 36″ or smaller opening, may not have the required space to fit the standard E. L. R. assembly. Always verify the distance from the end of the touchpad to the end rail, and if necessary, consult with the factory for appropriate selection. Remove and discard dogging from device. Slide the Electric Latch Retraction assembly into device and attach the linkage to the latch retraction rod (short linkage for standard, long linkage for 4′ device).

Carefully slide the assembly back out until the linkage JUST makes contact with the latch retraction rod. Tighten set screws.

NOTE Retro-Fitting Vertical Rod Devices:

Before retro-fitting an electric latch assembly into a vertical device, the following must be done to ensure proper alignment. Disconnect the vertical rods from the device head. Once the ELR is properly installed energize it so that the push pad is dogged down, by doing so it will allow for proper alignment for the vertical rods. Finally reconnect the vertical rods to the device and make the proper adjustments.

ELECTRICAL DATA
24VDC @ 700/200mARED (+) BLK (-)PATENT #8,851,530

WWW.SDCSECURITY.COM

E-mail: service@sdcsecurity.com

■ 801 Avenida Acaso, Camarillo, CA 93012
■ PO Box 3670, Camarillo, CA 93011

Documents / Resources

| SDC LR100IDCK-EM Electric Latch Retraction Device Kit [pdf] Installation Guide
LR100IDCK-EM Electric Latch Retraction Device Kit, LR100IDCK-EM, Electric Latch Retraction Device Kit, Latch Retraction Device Kit, Retraction Device Kit, Device Kit
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals