Door control relay modules ensure compatibility of access hardware components and simplify system installation and troubleshooting. Modules may be ordered with or without power supplies. Different modules may be specified for one power supply.
SDC’s CR4 series control boards are designed to allow for independent control of up to four separate electrified locking devices by distributing the primary DC power supply output into four, individually controlled relay outputs. Each station of CR4 series module accepts a dry, normally open trigger input and provides one fused and one non-fused output. Each output is individually fused and selectable as wet or dry. Closing a switch across the trigger input will release the output for the amount of time that the trigger input is held closed. Output voltage is determined by input voltage. Additionally, LED visual status indicators provide relay activation status.
MODELS
CR4 Four Station Control Relay
STANDARD FEATURES
- Reduced wiring, easier troubleshooting
- Four independent stations
- Four fused field selectable wet or dry outputs
- Four non-fused outputs
- Four dry contact trigger inputs
- Auto-sensing dual voltage
- Visual status indicators (LED)
APPLICATIONS
Control and distribute power to four individual door locks from a single power supply
CROSS REFERENCE
| CR4| ACM-1| EMC| FB-4| 12VR
---|---|---|---|---|---
| | | | |
Description| Four station control relays| Six input control relays| Dual
channel exit device sequencers| Four output power distribution modules|
Voltage power convertors
Application| Individual control of four locks| Control one lock with up
to six activation devices| Sequence electrified panic device and operator for
single or pair of doors| Distribute a single voltage output to four devices|
Convert 24 VDC to regulated 12 VDC output
Inputs| (4) N/O, Dry| (3) N/O, Dry
(3) N/C, Dry| (2) N/O, Dry| (1) Power, 12/24 VDC| (1) Power, 24 VDC
Outputs| (4) SPDT, Fused, Wet or Dry
(4) SPDT, Unfused, Wet or Dry| (1) SPDT, Wet
(1) SPDT, Dry| (4) N/O, Dry| (4) Fused Class 2, On/Off, 12/24VDC (Matches
input)| (1) Fused Class 2, 12 VDC
(1) Fused Class 2, 24 VDC
SPECIFICATIONS
| CR4
---|---
Input Voltage| 12/24 VDC ± 10%
Input Current (Max)| 150 mA
Dimensions| 41/4” x 313/32” x 5/8”
Stations| 4
Input Configuration (Per Station)| (1) Normally Open (N/O), Dry
Output Configuration (Per Station)| (1) SPDT, Fused-Wet/Dry
(1) SPDT, Non-Fused-Wet/Dry
Contact| 2 Amp @ 30 VDC Resistive
HOW TO ORDER
FOLLOW STEPS FOR ORDERING
Designates optional step
- SPECIFY MODEL
CR4 Four Station Control Relay STEP NUMBER:| 1
---|---
ORDERING EXAMPLE:| CR4
CUSTOMER SUPPORT
The lock behind the system
LIT-DS_CR4_020524
© 2024 Security Door Controls
sdcsecurity.com ■ 800.413.8783
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>