Elkay EDFP210C Soft Sides Single Fountain Instruction Manual

June 14, 2024
ELKAY

Elkay EDFP210C Soft Sides Single Fountain

Product Information

Specifications

  • Model Numbers: EDFP210CB, EDFP214CB, EDFPVR214CB, EDFP217CB
  • Water Inlet Size: 1/4″ O.D. Tube
  • Cold Water Supply Size: 3/8″ O.D. Unplated Copper Tube
  • Recommended Water Supply Location: 3/8″ O.D. Unplated Copper Tube, stubbed 1-1/2″ (38mm) from the wall
  • Recommended Waste Outlet Location (Model EDFP210C): 1-1/4″ O.D. Drain, stubbed 1-3/8″ (35mm) from the wall
  • Recommended Waste Outlet Location (Model EDFP214C): 1-1/4″ O.D. Drain, stubbed 6-5/8″ (168mm) from the wall
  • Trap Size: 1-1/4″
  • Mounting Holes Diameter: 3/8″ (10mm)

Installation Instructions

  1. Ensure that the wall is already framed for the fountain using the positioning dimensions shown in Figures 3 or 4. The dimensions shown are required for compliance with ANSI Standard A117.0 and must be able to support up to 150 lbs. of weight.
  2. Check your installation for compliance with plumbing, electrical, and other applicable codes.
  3. After installation, leave the instructions inside the fountain for future reference.
  4. Connect the water inlet to the cooler using a 1/4″ O.D. tube.
  5. Connect the cold water supply to the building water inlet using a 3/8″ O.D. unplated copper tube.
  6. Ensure that the water flow direction is correct (see FIG. 1).
  7. Install a service stop (not furnished) as shown in FIG. 2.
  8. For Model EDFP210C, recommended location for waste outlet is a 1-1/4″ O.D. drain stubbed 1-3/8″ (35mm) from the wall. For Model EDFP214C, recommended location for waste outlet is a 1-1/4″ O.D. drain stubbed 6-5/8″ (168mm) from the wall (see FIG. 3).
  9. Use the provided 1-1/4″ trap for the waste outlet.
  10. Secure the fountain to the wall using the provided 3/8″ (10mm) diameter holes (see FIG. 4).

FAQ

Q: Who should perform service on the product?
A: All service should be performed by an authorized service person.

Q: What are the recommended water supply and waste outlet locations?
A: The recommended water supply location is a 3/8″ O.D. unplated copper tube, stubbed 1-1/2″ (38mm) from the wall. The recommended waste outlet locations vary depending on the model: for Model EDFP210C, it is a 1-1/4″ O.D. drain stubbed 1-3/8″ (35mm) from the wall, and for Model EDFP214C, it is a 1-1/4″ O.D. drain stubbed 6-5/8″ (168mm) from the wall.

Q: How should I secure the fountain to the wall?
A: Use the provided 3/8″ (10mm) diameter holes for securing the fountain to the wall.

Q: What parts are included in the product?
A: The parts included in the product are as follows:

  1. DRAIN
  2. RETAINING NUT
  3. PUSH BUTTON
  4. PUSH BUTTON SLEEVE
  5. REGULATOR HOLDER
  6. ORIFICE ASSY
  7. HOUSING ASSY
  8. PEDESTAL
  9. BUBBLER LOCKNUT
  10. REGULATOR
  11. SCREW -CAP #6-32 X 5/16
  12. SCREW – #10-24 X .50 PHTC
  13. STRAINER
  14. FOUNTAIN ARM – SHORT
  15. FOUNTAIN ARM – LONG
  16. FOUNTAIN ARM – LONG (GLASSFILLER)
  17. BOTTOM COVER PLATE – SHORT
  18. BOTTOM COVER PLATE – LONG
  19. BACK PANEL ASSY – EDFP217C
  20. HEX NUT
  21. REGULATOR MOUNTING BRACKET
  22. KIT – BUBBLER (VR)
  23. POLY TUBING (CUT TO LENGTH)
  24. EDGE TRIM – 2FT.
  25. TEE – 1/4

EDFP210CB EDFP214CB EDFPVR214CB EDFP217CB

Installation/Care/Use Manual
Soft Sides™ Fountains with FLEXI-GUARD®

Installer

To assure you install this model easily and correctly,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave these instructions inside the fountain for future reference.

IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON

INSTALLATION

IMPORTANT! INSTALLER PLEASE NOTE.

THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.

LEGEND

  • A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUBBED 1-1/2″ (38mm) FROM WALL SHUT OFF BY OTHERS
  • B = MODEL EDFP210C: RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUBBED 1-3/8″ (35mm) FROM THE WALL MODEL EDFP214C: RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUBBED 6-5/8″ (168mm) FROM THE WALL
  • C = 1-1/4″ TRAP FURNISHED
  • D = 3/8″ (10mm) DIA. HOLES FOR SECURING FOUNTAIN TO WALL

EDFP217C

LEGEND

  • A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUBBED 1-1/2″ (38mm) FROM WALL SHUT OFF BY OTHERS
  • B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUBBED 1-3/8″ (35mm) FROM WALL
  • C = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUBBED 6-5/8″ (168mm) FROM WALL
  • D = 1-1/4″ TRAP FURNISHED
  • E = 3/8″ (10mm) DIA. HOLES FOR SECURING FOUNTAIN TO WALL F = 3/8″ (10mm) SLOTS FOR MOUNTING HANGER TO WALL
  • G = WALL HANGER FURNISHED LOOSE

PARTS LIST

ITEM NO.| PARTNO.| DESCRIPTION|
---|---|---|---


1

| ****

LK464

| ****

DRAIN

|
2| 15005C| RETAINING NUT|
3| 45662C| PUSH BUTTON|
4| 45663C| PUSH BUTTON SLEEVE|
5| 50986C| REGULATOR HOLDER|
6| A54874| ORIFICE ASSY|
7| 56011C| HOUSING ASSY|
8| 55997C| PEDESTAL|
9| 75580C| BUBBLER LOCKNUT|
10| 61313C| REGULATOR|
11| 75672C| SCREW -CAP #6-32 X 5/16|
12| 112627543890| SCREW – #10-24 X .50 PHTC|
13| 55996C| STRAINER|
14| 28782C| FOUNTAIN ARM – SHORT|
| 28783C| FOUNTAIN ARM – LONG|
| 27959C| FOUNTAIN ARM – LONG (GLASSFILLER)|
15| 55000661| BOTTOM COVER PLATE – SHORT|
| 55000665| BOTTOM COVER PLATE – LONG|
16| 27121C| BACK PANEL ASSY – EDFP217C|
17| 40045C| HEX NUT|
18| 28823C| REGULATOR MOUNTING BRACKET|
19| 70892C| KIT – BUBBLER (VR)|
20| 56092C| POLY TUBING (CUT TO LENGTH)|
21| 56369C| EDGE TRIM – 2FT.|
NS| 70682C| TEE – 1/4|

NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 9 OR 21) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN.

INSTALLATION INSTRUCTIONS

  1. Wall should already be framed for the fountain using the positioning dimensions shown in Figures 3 or 4. Shown dimensions pertain to installation location (framing must support up to 150 lbs. weight). These dimensions are required for compliance with ANSI Standard A117.0.
  2. Install rough-in plumbing as shown in Figures 3 or 4. Waste line should extend a minimum of 2″ (51mm) through the back panel. Run the supply water inlet line through the back panel. Install a service stop (not provided). Turn on supply water and flush thoroughly.
  3. Remove bottom access panel from fountain basin and save the screws. Install the fountain to the back panel and wall using (4) 5/16″ x 2″ long lag bolts and washers (not provided) through holes in back panel. Tighten securely.
  4. Remove elbow from end of p-trap and attach it to drain tube. Reattach elbow to p-trap and cut waste tube to required length using plumbing hardware and trap as a guide.
  5. Make water supply connections from service stop to the 3/8″ O.D. unplated copper tube coming out of the strainer. Turn on water supply and check for leaks. Newly installed water supply line should be insulated after leak check is completed. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
  6. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above 105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not covered by warranty.
  7. Check stream height from bubbler. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust the screw on the regulator (Item 10) by using a small screw driver through the small hole in the push button (Item 3). Clockwise adjustment will raise stream height and counter-clockwise will lower stream height. For best adjustment stream should hit basin approximately 6-1/2″ (165mm) from bubbler.
  8. Replace bottom access panel to fountain using the screws provided. Tighten securely.

TROUBLESHOOTING AND MAINTENANCE

  1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from orifice with a small round file not over 1/8″ diameter or a small diameter wire.
    CAUTION: Do not file or cut orifice materials.

  2. Stream Regulator: If orifice is free of material deposits, regulate flow according to instruction 7 stated above.

  3. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing (See Figure 2). To insert tubing, push tube straight into the fitting until it reaches a positive stop, approximately 3/4″.

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
ELKAY MANUFACTURING COMPANY • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>