Product Specifications:

  • Model: ENLZS8WS-W1_1A
  • Enhanced LZ TM Series Bottle Filling Stations & Coolers
  • Smart Connected-Ready
  • Patent: zurn-elkay.com/patents

Product Usage Instructions

Installation Guidelines:

Follow these steps for proper installation:

  1. Identify recommended water supply location (A) for connecting stub with shut-off valve.
  2. Locate waste outlet location (B) with drain stub and trap.
  3. Ensure electrical supply with a recessed box duplex outlet (D).
  4. Maintain proper ventilation and ADA compliance by keeping a minimum clearance from cabinet louvers to the wall (E).
  5. Use the provided bolt holes for fastening the unit to the wall (F).

Removing Wrapper Instructions:

  1. Remove the two security screws (size T25) from the front panel.
  2. Gently pull down and rotate the wrapper to a downward position.
  3. To completely remove the wrapper, hold each side and gently pull it up and out of the pivoting bracket.

Important Notes:

  • Be cautious as the wrapper may drop and swing when security screws are removed.
  • Avoid leaning on the wrapper and refrain from using power tools to tighten or overtighten screws.

Wrapper Reattachment:

  1. Ensure each side of the wrapper is engaged to the pivoting bracket.
  2. Align the holes on the wrapper with plastic bushing threads before engaging security screws.
  3. Hand tighten screws before using a hand tool to avoid cross-threading.

Frequently Asked Questions (FAQ):

Q: Can I use a power tool to tighten the security screws?
A: No, it is advised not to use a power tool to tighten the screws to prevent damage.

Q: How should I remove the wrapper for servicing?
A: Follow the provided steps in the manual to safely remove the wrapper for servicing purposes.

Q: What should I do if the wrapper does not align properly during reattachment?
A: Ensure each side of the wrapper is correctly engaged with the pivoting bracket and align the holes with plastic bushing threads before securing with screws.

Patent zurn-elkay.com/patents

WARNING: Cancer and Reproductive Harm – www.P65Warnings.ca.gov

DIAGRAM

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(1\)

Fig. 1

REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER

LEGEND

  • A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
  • B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUB 2 IN. OUT FROM WALL
  • C = 1-1/4″ TRAP NOT FURNISHED
  • D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET**
  • E = INSURE PROPER VENTILATION AND ADA COMPLIANCE BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
  • F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
    NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)

NOTE: IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS AND UTILZE HOSPITAL-GRADE GFCI.

INSTRUCTIONS FOR REMOVING WRAPPER

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(2\)

  1. Remove the two security screws (size T25) from the front panel. (see Fig B(i))
    NOTE: SCREW THREADS INTO BUSHING WHILE ANGLED. DO NOT ATTEMPT TO THREAD SCREW INTO BUSHING HORIZONTALLY.

  2. Gently pull the wrapper down and rotate the wrapper to a downward position (see Fig B(ii)).

  3. To remove the wrapper, hold each side and gently pull wrapper up and out of pivoting bracket
    (see Fig B(iii)).

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(3\)

CAUTION:

  • WRAPPER DROPS AND SWINGS WHEN SECURITY SCREWS ARE REMOVED.
  • DO NOT LEAN ON WRAPPER.
  • DO NOT USE POWER TOOL TO TIGHTEN. DO NOT OVERTIGHTEN.

NOTE:

  1. Ensure that there are no plumbing or external objects below the wrapper in the specified dimension.
    The specified (3.27’’) minimum distance is required for the wrapper to swing out (see Fig B(iv)).

  2. Removing the wrapper from the pivoting bracket when servicing the unit is recommended. The wrapper may be left in place for quick serviceability (see Fig B(iii)).

  3. When re-attaching wrapper, ensure each side of wrapper is engaged to pivoting bracket (see Fig B(v)).

  4. Once the wrapper is in place, rotate wrapper up and under the shroud. Ensure thru holes on wrapper are aligned with plastic bushing threads on the frame prior to engaging security screws. Ensure screw is angled relative to the ground and perpendicular to wrapper surface prior to engagement. Hand tighten prior to using hand tool to avoid cross-threading.

  5. Four plastic bushings are located in the cross brace of the frame. The lower two bushings align with wrapper holes and the top two bushings are extras in case of replacement (see Fig B(iii)).

HANGER BRACKET INSTALLATION

  1. Remove hanger bracket fastened to back of cooler by removing one (1) screw.

  2. Mount the hanger bracket as shown in Figure 1 (Pg. 2).
    NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.
    IMPORTANT: 5-7/8 in. (150mm) dimension from wall to centerline of trap must be maintained for proper fit.
    INSTALLATION OF COOLER

  3. Hang the cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 1 (Pg. 2).

  4. Refer Fig B(i) to B(iv), Pg. 3 for wrapper removing instructions.

  5. Secure cooler frame to wall by installing (2) screws and washers (not supplied) in lower holes. (See Fig. 2, Pg. 5). Make sure the screws engage in a structural member.

  6. Connect the supply water to the filter inlet tube.

  7. Install trap.
    IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.
    BOTTLE FILLER INSTALLATION

  8. Remove two (2) mounting screws with 5/32″ Allen wrench holding bottle filler to wall mounting plate (See Fig.8, Pg. 6). Note do not discard mounting screws, they will be
    needed to secure bottle filler to wall mounting plate.

  9. Remove wall mounting plate from Bottle Filler (see Fig 8, Pg. 6). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the six (6) mounting holes with a pencil. Place tape over wiring harness connection on top of cooler to prevent debris from falling into Connection.

  10. Remove wall mounting plate from wall. NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.

  11. Install wall mounting plate to wall using six (6) 7/16″ obround mounting holes (mounting bolts not included) (See Fig.8, Pg. 6). Use appropriate fasteners for your wall type.

  12. Install gasket on bottom of bottle filler tower with gasket support bracket & (2) screws. (See Fig. 4, Pg. 5).

  13. Route 3/8” tubing through the opening in the bottle filler gasket and plug into bulkhead fitting in basin. Route the wiring harness through the gasket and plug into the connector on the top of the basin. Water line should be cut to length prior to attaching to bulkhead fitting.

  14. Place bottle filler on four (4) hooks on the mounting plate installed on wall. Make sure round boss in gasket fits in hole of basin. (See Fig. 8, Pg. 6).

  15. Plug electrical cord into outlet on wall.

  16. Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that front facing label can be read
    when filter is installed. (See Fig. 11, Pg. 8).

  17. Turn water supply on and inspect for leaks in both cooler and bottle filler. Fix all leaks before continuing.

  18. Reinstall two mounting screws from first step (See Fig. 8, Pg. 6). Caution, do not over tighten screws.

  19. Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.

  20. Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify water dispenses. NOTE: The first initial dispenses might have air in
    line which may cause a sputter or hazy appearance of water. This will be eliminated once all air is purged from the line. Run water and flush filter to purge air and fine carbon
    particles from filter before use. Visit elkay.com/filtration for additional details.

  21. Once unit tests out, install Lower Panel back on water coolers.

  22. When re-attaching wrapper, push wrapper up and under the shroud. Make sure wrapper and bushing holes are aligned prior to inserting screw. Units are now ready for use.

Instructions For Replacing Filters

  1. Refer Fig B(i) to B(iv), Pg. 3 for wrapper removing instructions.
  2. Turn off water supply; dispense water to relieve pressure.
  3. Remove power by unplugging cooler.
  4. Turn used filter counterclockwise 1/4 turn to remove from filter head.
  5. Remove cap from new filter and use to seal used filter.
  6. Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig.11, Pg. 8).
  7. Plug in unit to restore power.
  8. Turn on water supply and flush filter to purge air and fine carbon particles from filter before use. Visit elkay.com/fi ltration for additional details. Also run water through bottle filler until all air is removed and water flow is clear.

Note: Filter status light will automatically reset once new filter is installed.

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(20\)

Instructions To Access Programming Button

  1. Remove lower cover on refrigerated unit by removing (2) screws (see Fig 7, Pg. 6) and rotating the front panel down (see Fig B(i) to B(iv), Pg. 3) for wrapper removing instructions.
  2. Button is located in lower right corner of unit (See Fig. A, Pg. 4).

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(5\)

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(6\)

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(7\)

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(8\)

Wiring Diagram

115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connected-Ready – Enhanced Bottle Filler

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(10\)

OPERATION OF QUICK CONNECT FITTINGS

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(11\)

NOTE:
When installing replacement bubbler and pedestal, tighten nut only to hold parts snug in position. Do Not Overtighten.

Scan for trouble shooting and to sign up for auto replenishment of authentic Elkay filters.

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(15\)

WATERSENTRY® Filter Detail

WATERSENTRY ® **** FILTER PARTS LIST

ITEM NO.| PART NO.| DESCRIPTION
A| 51600C| Filter Assy – 6000 Gal.
B| 1000005214| Kit – Filter Head Fittings includes
 |  | John Guest Fittings & 3/8” Elbow
 |  | Filter Bracket/Screws
C| 1000004409| Kit – NFC Board/Cover

Service Instructions

Lower and Upper Shroud
To access the refrigeration system and plumbing connections, Remove two (2) screws from front of cooler to remove the lower shroud. To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.

Bubbler
To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be reached through the access panel on the underside of the upper shroud. Remove the access panel by removing the retaining screw. To remove the bubbler, loosen locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw.

Switches Behind the Push Bar
The regulator in an EZ cooler is always held fully open by the use of a single regulator nut (See Item 9, Fig. 14). Water is not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve.

To remove sidebars, from the inside compress the flared tabs and pull out carefully. To reinstall side pushbars, the front of the pushbar is inserted first. While keeping the switch depressed, snap the rear of the pushbar into position.

Cleaning

Stainless Steel

  • General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
  • Steel soap pads should never be used; particles can adhere to a stainless steel basin surface and will eventually rust.
  • Light scratches are normal for stainless steel basins; over time they will blend into the uniform fi nish pattern.
  • Do not use cleaners containing acids or chlorides, these will cause the stainless steel to oxidize.

Plastic Components

  • General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
  • Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties.
    Fig. 14

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(18\)

Temperature Control

  • Factory set at 50°F (+/- 5°F) under normal conditions. For altitude adjustments, refer to sticker on left side of top bar.

Stream Height Adjustment
VIEW OF UNDERSIDE OF BASIN SHROUD

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(16\)

Programming Instruction

Depress Button for 3 seconds to activate main menu – release
Cycles thru main menu items 2 seconds each for 2 cycles then exits menu unless selected
Cycles thru sub menu items 2 seconds each for 2 cycles then returns to main menu unless selected
Selections are saved when the menu is exited

Top leve l| Action| Sub Menu 1| Action| Sub Menu/action| Action| Sub Menu/ action| Action| Sub Menu/ action| Notes| End Action
---|---|---|---|---|---|---|---|---|---|---
Info| Momentary| Scrolls through all the settings on unit|  |  |  |  |  |  | | Returns to Main Menu
Info| Momentary| Flashes error code|  |  |  |  |  |  |  | Returns to Main Menu
Set time| Momentary|  |  |  |  |  |  |  |  | Drops to next level when selected
 | Day (Sunday-Saturday| Momentary|  |  |  |  |  | Use push button to select the day on the display| Drops to next level when selected
 | AM/PM| Momentary|  |  |  |  |  | Use push button to select AM or PM| Drops to next level when selected
 | Hour (12 hour)| Momentary|  |  |  |  |  | Use push button to select Hour| Drops to next level when selected
 | Min 0-69 in 5 minute increments| Momentary|  |  |  |  |  | Use push button to select closest minute| Returns to Main Menu
Filter| Momentary|  |  |  |  |  |  |  |  | Drops to next level when selected
 | No| Momentary| Turn off filter status and errors|  |  |  |  | No Filter unit – Error codes related to filter status

turned off

| Returns to Main Menu
 | Yes| Momentary| Default setting – Turn on filter status and errors|  |  | |  | Filter status has default ON / Default has read write

to filter, LED status display, filter error capability

| Returns to Main Menu
Refrig| Momentary|  |  |  |  |  |  |  |  | Drops to next level when selected
 | No| Momentary| Disables E/S relay sets bottle fill time to 1.5gpm|  |  |  | | Refrigeration off| Returns to Main Menu
 | Yes| Momentary| Default setting – Enables E/S relay – sets time to 1.1gpm| |  |  |  | Refrigeration on| Returns to Main Menu
Range| Momentary|  |  |  |  |  |  |  | The lower the number, the closer to the sensor the

bottle needs to be to activate

| Drops to next level when selected
 | 1-10| Momentary| Default setting 5 – Adjusts distance from sensor the bottle needs to be before turning before turning on or off the bottle filler| |  |  |  |  | Returns to Main Menu
B-Light| Momentary|  |  |  |  |  |  |  | The settings are for the brightness of the display and night light| Drops to next level when selected
 | 25%| Momentary|  |  |  |  |  |  | Returns to Main Menu
 | 50%| Momentary|  |  |  |  |  |  | Returns to Main Menu
 | 75%| Momentary| Default Setting|  |  |  |  |  | Returns to Main Menu
 | 100%| Momentary|  |  |  |  |  |  | Returns to Main Menu
EnerSave| Momentary|  |  |  |  |  |  |  |  | Drops to next level when selected
 | Off| Momentary| Default Setting|  |  |  |  |  | Returns to Main Menu
 | On| Momentary| Set Energy Save Schedule|  |  |  |  |  | Drops to next level when selected
 |  |  |  |  | Select Weekday|  |  |  | Drops to next level when selected
 |  |  |  |  |  | Momentary| Select time on| 24 hours – 1-12AM and 1-12PM| Drops to next level when selected
 |  |  |  |  |  | Momentary| Select time off| 24 hours – 1-12AM and 1-12PM| Drops to next level when selected
 |  |  |  |  | Select Weekend|  |  |  | Drops to next level when selected
 |  |  |  |  |  | Momentary| Select time on| 24 hours – 1-12AM and 1-12PM| Drops to next level when selected
 |  |  |  |  |  | Momentary| Select time off| 24 hours – 1-12AM and 1-12PM| Returns to Main Menu

Enhanced EZH2O Error Codes

Error Code Error Description Corrective Action
  Bottle filler area obstructed ·  Remove obstruction.

·  Clean lens on IR sensor

·  Unplug unit for at least 30 seconds and restart

·  If error repeats, replace IR sensor

E013| Missing or Incompatible Filter| ·  Check that filter is installed correctly (label facing forward, white tag fac- ing back)

·  Unplug unit for at least 30 seconds and restart

·  Replace filter

·  Replace filter head assembly with repair kit

·  If error repeats, contact certified service professional

E013 &

E014

| Missing NFC Board| ·  Unplug unit for at least 30 seconds and restart

·  Verify cable connector is plugged into NFC board on filter head assembly

·  Replace filter head assembly with repair kit

·  If error repeats, contact certified service professional

Bottle Filler

Pictured is unit only without bottle filler.

Note: Danger! Electrical shock hazard. Disconnect power before serviceing unit.

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(19\)

115V PARTS LIST

ITEM NO. PART NO. DESCRIPTION
1 28401C Hanger Bracket
2 0000001337 Basin – Stainless Steel
3 36216C Wiring – Front/Side Push Bar
*4 36322C Compr – Service Pak 115V EMIS70HHR
5 56092C Tube – Poly (72”)
6 56229C Assy – Shroud – Upper (Front Side Push)
7 66703C Drier
8 1000001877 Kit – Drain Replacement (Bottle Filler) (Bracket, Tube,

Fitting, Clamp)
9| 1000004564| Kit – Regular/Holder/Nut
10| 1000004572| Kit – Solenoid Valve/Regulator Assembly
11| 56073C| Kit – Flexi Bubbler/“O”-Ring/Nut
12| 98734C| Kit – Pushbar (Front/Side) EZS TL
13| 1000001600| Kit – Pushbar (Front Only)
14| 1000004568| Power Cord
15| 98775C| Kit – Fan Motor/Blade/Screws/Nut
16| 98776C| Kit – Condenser/Drier/Wire Ties
17| 98777C| Kit – Compr Mtg Hdwe/Grommets/Clips/Studs
18| 98778C| Kit – Heatx/Drier
19| 98898C| Kit – Hardware
20| 0000000238| Kit – 115V Electricals (Relay, Overload, Cover)
21| 98724C| Kit – Evap. Replacement
22| 1000001812| Kit – Bottle Filler Drain
23| 56237C| Shroud
24| 1000001602| Kit – 75583C Elbow 5/16″ x 1/4″ (3 Pack)
25| 1000004559| Wire Assy – Jumper
26| 56213C| Access Panel
27| 1000004547| Harness – Cooler
28| 1000004550| Wire – 6” Jumper
29| 98773C| Kit – Cold Control
NS| 1100000018| Drop Down Wrapper Replacement Kit – Stainless Steel

NS = Not Shown

INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.

NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.

ATTENTION:
If the product serial number is before 190424189, please refer to archived documents section of Elkay.com for the most accurate parts list.
(www.elkay.com/archived-documents)

BOTTLE FILLER
REPLACEMENT PART KITS

ELKAY-LZS8WSSP-W1-Bottle-Filling-Stations-and-Coolers-FIG-
\(21\)

NS = Not Shown

Register in plumbSMART

  1. Install Zurn Gateway (required and sold separately) per the gateway instruction manual, if an existing gateway is not within communication range.
  2. If you have not already set up an enterprise account and your administrator access, Zurn creates your Enterprise Account for you! (you will be required to identify your building location, number of floors, and number of rooms.) and request plumbSMART administrator account at 844-987-6737.
  3.  Log into plumbsmart.zurn.com
  4. Register each Connected product in plumbSMART (Watch How-To videos to get started. Located in the support section inside the portal.)

Note: Refer to the plumbSMART Registration ID label (See Fig. 8a, Pg. 6).

FCC COMPLIANCE STATEMENT

CAUTION: Changes or modifications not expressly approved could void your authority to use this equipment
This device complies with Part 15 of the FCC Rules. Operation to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation

Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.

The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with RSS-102 radiation exposure limits. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
ELKAY MANUFACTURING COMPANY • 1333 BUTTERFIELD ROAD • DOWNERS GROVE, IL 60515 • 630.574.8484 • www.elkay.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals