Mr Steam 104480 XDream Generator Package Instruction Manual
- June 16, 2024
- Mr.Steam
Table of Contents
- 104480 XDream Generator Package
- IMPORTANT SAFETY INSTRUCTIONS
- Box Contents:
- Dimensional Information
- Locating the Control
- Installation Instructions for iSteamX
- Operating Instructions
- Start Screen
- ChromaSteam
- System Settings
- Care Tips
- Warranty
- Description of Operation
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Installation, Operation & Maintenance Manual
iSteamX
Feel Good Inc.
104480 XDream Generator Package
READ ME FIRST!
WARNING
As you follow these instructions, you will notice warning and caution symbols.
This blocked information is important for the safe and efficient installation
and operation of this generator. These are types of potential hazards that may
occur during installation and operation:
WARNING
Indicates a potentially hazardous situation, which, if not avoided, could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation, which, if not avoided may result
in minor or moderate injury or product damage.
This highlights information that is especially relevant to a problemfree
installation.
All information in these instructions is based on the latest product
information available at the time of publication.
Mr.Steam reserves the right to make changes at any time without notice.
When installing and using this electrical equipment, basic safety precautions
should always be followed, including the following:
IMPORTANT SAFETY INSTRUCTIONS
-
WARNING
READ AND FOLLOW ALL INSTRUCTIONS -
WARNING
Do not permit children under the age of 16 to use this steambath. Steam is hot and can cause injury or death if improperly used.
Steam rooms contain steam and elevated temperatures. Please read and observe all warnings in this manual before installing or using a steam room. -
To reduce the risk of injury:
WARNING
A. The wet surfaces of steam enclosures may be slippery. Use care when entering or leaving.
B. The steam head is hot. Do not touch the steamhead and avoid the steam near the steamhead.
C. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia).
Limit your use of steam to 10-15 minutes until you are certain of your body’s reaction.
D. Excessive temperatures have a high potential for causing fetal damage during the early months of pregnancy.
Pregnancy or possibly pregnant women should consult a physician regarding correct exposure.
E. Obese persons and persons with a history of heart disease, low or high blood pressure, circulatory system problems, or diabetes should consult a physician before using a steambath.
F. Persons using medication should consult a physician before using a steambath since some medication may induce drowsiness while other medications may affect heart rate, blood pressure and circulation.
SAVE THESE INSTRUCTIONS
HYPERTHERMIA occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 98.6° F. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the steambath;
c) Unawareness of impending risk;
d) Fetal damage in pregnant women;
e) Physical inability to exit the steambath; and
f) Unconsciousness.
WARNING
The use of alcohol, drugs, or medication can greatly increase the risk of
hyperthermia.
Box Contents:
- iSteamX Control
- iSteamX Hub
- Power Supply
- Control Cable w/Mini-Din (30ft)
- iSteamX cable w/Screw connector (30ft)
- Steamhead
- Tube of silicone sealant
- Owner’s manual
Dimensional Information
iSteamX
iSteamX Hub
WARNING
To avoid unintentional steambath
operation, do not locate the control where other
controls, accessories, shower heads, valves, body sprays
or similar within the shower could cause confusion or
interfere with the Mr.Steam control’s intended use and
function.
CAUTION
- To prevent possible injury Do Not use the iSteamX control without reading and understanding the Mr.Steam steam generator Installation and Operation Manual.
- A peel and stick warning sticker is provided in the Mr.Steam steam generator Installation, Operation and Maintenance Manual. This manual is provided with every steam generator. The warning sticker must be read and permanently affixed in a conspicuous location near the steam room. Failure to read and affix this warning sticker in a conspicuous location may result in serious injury or death. Please call Mr.Steam at 800 767-8326 for a free replacement or if you have any questions regarding the warning sticker.
WARNING
REDUCE THE RISK OF OVERHEATING AND SCALDING
-
EXIT IMMEDIATELY IF UNCOMFORTABLE, DIZZY OR SLEEPY.
STAYING TOO LONG IN A HEATED AREA IS CAPABLE OF CAUSING OVERHEATING. -
SUPERVISE CHILDREN AT ALL TIMES.
-
CHECK WITH A DOCTOR BEFORE USE IF PREGNANT, DIABETIC, IN POOR HEALTH OR UNDER MEDICAL CARE.
-
BREATHING HEATED AIR IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL, DRUGS, OR MEDICATION IS CAPABLE OF CAUSING UNCONSCIOUSNESS.
-
DO NOT CONTACT STEAM HEAD OR STEAM AT THE STEAM HEAD.
REDUCE THE RISK OF SLIPPING AND FALL INJURY
- USE CARE WHEN ENTERING OR EXITING THE STEAM ROOM. FLOOR MAY BE SLIPPERY NOTE: FOR ADDITIONAL SAFETY CONSIDERATIONS SEE OWNER”S MANUAL WHICH IS KEPT:___
THE OWNER’S MANUAL CAN BE FOUND AT WWW.MRSTEAM.COM USE OF STEAM ROOM IN CONJUNCTION WITH CONSUMPTION OF ALCOHOL CAN BE DANGEROUS AND CAN RESULT IN INJURY THROUGH SLIP AND FALL OR OTHERWISE.
IMPORTANT NOTES:
-
Turn power to the steam generator OFF before connecting the control to the generator. Failure to turn the power off will result in an inoperable control.
-
Do not operate the iSteamX control with other than a Mr.Steam iSteamX compatible steam generator.
Mr.Steam residential steam generators with serial numbers lower than 1174000, or any other brand of steam generator are not to be operated with iSteamX controls. Doing so may result in an inoperative installation. If your generator’s serial number is lower than 1174000 contact Mr.Steam Technical Service for up-grade options and components to enable your steam generator to function with iSteamX. -
This document contains important safety, operation and maintenance information. Leave this document with the homeowner. Do not discard this document.
-
Discontinue use of the steam generator or control if the steam generator is damaged or otherwise not functioning properly. Doing so may result in an inoperative or hazardous installation
-
Refer to the Steambath Generator Installation, Operation and Maintenance Manual for locating and installing the steamhead.
Do Not alter or modify any Mr.Steam products. Doing so may result in an inoperable or hazardous installation and will void the warranty.
Locating the Control
Determine the desired installation location of the control. The iSteamX controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed inside the steam room:
- Locate the control 4-5 feet above the floor near the bather seating area.
- The control features an integral temperature sensor. Locate the control in a location representative of the desired steam bathing temperatures. Do not locate the control above or near the steam head or direct steam emissions.
- Locate the control on a vertical wall.
- The control cable is 30 feet. Insure that the control and steam generator are located accordingly.
IMPORTANT NOTES:
- If required, contact Mr.Steam to purchase an optional 60’ iSteamX control cable part number 104541-60.
- If the control is installed outside the steam room a Remote Temperature Probe Part Number MSTS must be installed inside the steam room. Refer to the MSTS installation manual before installing the control.
- Ensure Mr.Steam steam generator is iSteamX compatible and has a serial number 1174000 or higher.
STEP 1
Make a 1-1/4″ diameter hole in the desired control location.
STEP 2
Route the control cable from the wall cutout to the iSteamX
Hub. Plug in and thread the connector collar into the Hub at thelocation
marked Control.
IMPORTANT NOTE: The connector is keyed, it will only connect one way.
IMPORTANT NOTE: The control cable should be in a dedicated 1” conduit to
facilitate installation and service. Be careful not to strain, staple, pinch
or otherwise damage the control cable. Route cable as required to permit
replacement.
Do not route cable inside conduit together with power lines or close to hot
water or steam piping.
Do Not Route control wiring inside conduit together with power wiring or close
to hot water or steam piling. Doing so may result in an inoperative or
hazardous installation
Finish the iSteamX installation using the instructions on page 7.
Installation Instructions for iSteamX
STEP 1.
Mount the hub securely. The hub may be mounted in any orientation.
Plug the 30 foot generator cable into the generator and into the hub.
Do not force or twist cable ends together. Forcing or twisting cable ends may
damage the connectors.
Plug the 30 foot control cable into the hub and into the iSteamX. Thread to
connector collars together.
Plug the hub’s power supply into an outlet.
Important Note: iSteamX must have an Internet connection for some
functions. iSteamX may be connected to Wi-Fi. If iSteamX is located in an area
with a poor Wi-Fi signal, a LAN connection from the router can be plugged into
the iSteamX HUB.
STEP 2
Peel the double stick adhesive off the back of the iSteamX control (2a). Apply
a bead of silicone around the rear of the iSteamX control to create a moisture
seal (2b).
Carefully feed the cables into the rough-in box and secure the control to the
wall. Care must be taken to not pinch the cables. Ensure the control is level.
IMPORTANT NOTE: The control must be installed.
NOTE: The silicone supplied by Mr.Steam can be used to meet a variety of
sealing and gasketing. It cures to silicone rubber and adheres to glass, wood,
metal, porcelain, ceramic tile, painted surfaces, many plastics and rubber.
Surfaces must be clean and dry. Apply thin layer of product. Fit together and
support if necessary.
Allow excess material to cure, then trim with a sharp blade. Sealant “skins”
in 5 minutes, dries to touch in 1 hour. Fully cures and bonds in 24 hrs.
IMPORTANT NOTE: Do not apply excessive amounts of silicone. Do not apply
silicone to any other parts of the control including the adhesive gasket.
Ensure the mounting surface is clean and dry as required for good adhesion.
Hold the control with the arrow on the screen protector facing up and press
the control against the wall until the adhesive sticks and holds firmly.
Control may have to be supported or secured until the silicone has cured for
24 hours.
READ ME FIRST!
WARNING As you follow these instructions, you will notice warning and
caution symbols. This blocked information is impor- tant for the safe and eff
icient installation and operation of this generator. These are types of
potential hazards that may occur during installation and operation:
As you follow these instructions, you will notice warning and caution symbols.
This blocked information is important for the safe and efficient installation
and operation of this generator. These are types of potential hazards that may
occur during installation and operation:
Indicates a potentially
WARNING Indicates a potentially hazardous situation, which, if not hazardous
situation, which, if not avoided, could result in death or serious injury.
CAUTION Indicates a potentially hazardous situation, which, if not avoided may
result in minor or moderate injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a
problem-free installation.
All information in these instructions is based on the latest product
information available at avoided, could result in death or serious injury.
Indicates a potentially
hazardous situation, which, if not avoided may result in minor or moderate
injury or product damage.
IMPORTANT NOTE: This highlights information that is especially relevant to a
problem-free installation.
All information in these instructions is based on the latest product
information available at the time of publication. Mr.Steam any time without
notice.
Operating Instructions
WARNING
Set the steam bathing duration and temperature according to personal
preference, however it is highly recommended to begin steam bathing at a low
temperature setting to gauge comfort and safety levels. Set the duration at 10
minutes maximum to gauge comfort and safety levels. This will allow the steam
generator to heat up and begin producing steam.
Stand-By Screen
Touch anywhere on the clock screen to wake up the control
Start Screen
Press the START button to turn the steam generator on. If you had selected a user profile and program when the control was woken up they system will start with the saved parameters. Steam will begin to slow a few minutes after the START button is pressed. The time required for the steam room to reach steam bathing temperature depends on the steam room construction and steam generator specifications
Program Selection
User settings can be adjusted two ways, while steam is running drag the
dashboard up from the bottom of the screen. AromaSteam can be turned ON/OFF,
ChromaSteam can be turned ON/OFF and color adjusted and the room temperature
can be adjusted.
Steam Settings
Steam settings can also be adjusted by tapping the Steam Settings icon on the
main screen. From the steam setting screen select either Temperature or
Duration. To adjust temperature use the + and – buttons. To adjust duration
swipe the time up and down. To return to the main screen tap the X in
theupper right.
ChromaSteam
The ChromaSteam is an optional accessory that activates colored lights in the
steam room. Press the ChromaSteam button to access the dashboard. The light is
turned ON/OFF from the interface. Touch anywhere on the color wheel to select
that color. To adjust brightness, use the slider on the bottom of the
ChromaSteam dashboard.
(Note: Brightness cannot be adjusted in automatic color changing modes)
Press the discrete color selection button to pick from a preselected set of
colors or one of the two color changing modes.
AromaSteam
The AromaSteam is an optional accessory that automatically infuses aromatic
oils into the steam flow. Press the AromaSteam button to bring up that
AromaSteam dashboard
Apps
iSteamX must be connected to WiFi to use apps
iSteamX must be paired with a Mr.Steam Audio@Home to hear audio from apps
iSteamX includes a preinstalled selection of popular entertainment apps. Apps
cannot be added or removed from iSteamX. The user interface of the
preinstalled Apps may differ slightly from those apps installed on
Smartphones. User accounts for the 3rd party apps are required to use some/all
of their features.
Access Apps by pressing the Features icon.
When apps are running they can be closed by pressing the icon or minimized by
pressing the icon. Use the icon to go back.
User Profiles & Setting
User profiles are found in the features menu. Press Add Profile to create a
user profile. Once a user profile is created, it can be made active by tapping
the profile name. User profiles can be deleted by pressing the trashcan.
User Programs
In the features menu select a profile before creating a program. To create a
program press the add program button. A keyboard will open and the user will
be prompted to name a program.
Each program can include a setting for steam and if equipped color of
ChromaSteam. Select which options to include in the program by checking the
box. Navigate through the set up by pressing the NEXT button
System Settings
Password Lock
The password lock can help prevent unintentional use of the steambath. Please
refer to the steam generator installation, operation and maintenance manual
before using the steambath. The passcode lock cannot ensure unintentional use
of the steambath
To turn the password lock on, press ON and then enter a number when prompted
and confirm to save. The next time iSteamX is turned on the user will be
prompted to enter the password.
AutoStart
AutoStart will automatically turn the steam generator on at your preset time.
Activating the steam in an occupied room may subject persons to hazards
described in this manual. Only activate the steambath if the steam room door
is closed. Activating or using the steambath with an open door may cause
property damage or injury to persons outside of the steam bath.
The AutoStart feature can be used to turn on the steambth at a predetermined
time. Select the day(s) of the week and the time of day you would like to turn
the steam bath on.
When AutoStart starts your steambath it will allow the steambath to run for
only 10 minutes. To continue steam bathing press the continue button. If the
continue button is pressed AutoStart will remain active.
To stop the steam bath press the STOP button If the STOP button or 10 minute
time out turns the steam generator off. AutoStart will automatically be
deactivated.
To create an AutoStart time tap the Add Start Time button. Select the start
time and day(s) of the week for AutoStart. A maximum of 8 start times can be
programmed. To delete a start time, press the trash icon.
To turn AutoStart on press the ON button.
.
Turning iSteam On and Off:
- To power the iSteam on, momentarily press the button on the bottom edge.
- To power the iSteam off, press and hold the button on the bottom edge of the control. Follow the onscreen prompts for power the iSteam off
Care Tips
Use only mild soap and water on a soft cloth to clean the control. Do not use
abrasive cleansers.
Safety & Operating Information
WARNING
A peel and stick warning sticker is provided in the Mr.Steam steam generator
Installation, Operation and Maintenance Manual. This manual is provided with
every steam generator. The warning sticker must be read and permanently
affixed in a conspicuous location near the steam room. Failure to read and
affix this warning sticker in a conspicuous location may result in serious
injury or death. Please call Mr.Steam at 800 767-8326 for a free replacement
or if you have any questions regarding the warning sticker.
Set the steam bathing duration and temperature according to personal
preference, however it is highly recommended to begin steam bathing at a low
temperature setting to gauge comfort and safety levels. Set the duration at 10
minutes max. to gauge comfort and safety levels. This will allow the steam
generator to heat up and begin producing steam.
CAUTION
Do not use any iSteamX control without reading and understanding the Mr.Steam
steam generator Installation and Operation Manual (PN 100472). Failure to read
and understand these instructions may result in an inoperative or hazardous
installation.
CAUTION
If an iSteamX control is installed outside the steam room a Remote Temperature
Probe (PN MSTS) must be installed inside the steam room per installation
instructions supplied with the Remote Temperature Probe.
Failure to install according to instructions will result in an inoperative
control and overheating of the steam room.
Warranty
To view or download the MrSteam Control Warranty and register your product go
to: blog.mrsteam.com/wr
Warranty
To view or download the MrSteam Control Warranty and register your product go
to: blog.mrsteam.com/wr
FCC Statement:
Any Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
This device may not cause harmful interference, and 2. This device must
accept any interference received, including interference that may cause
undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
nterference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.
ISED Statement:
This device contains licence-exempt transmitter(s)/receiver(s) that comply
with Innovation, Science and Economic Development Canada’s licenceexempt
RSS(s). Operation is subject to the following two conditions:
- This device may not cause interference.
- This device must accept any interference, including interference that may cause undesired operation of the device.
The device meets the exemption from the routine evaluation limits in section 2.5 of RSS-102 and compliance with RSS-102 RF exposure, users can obtain Canadian information on RF exposure and compliance. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body.
Description of Operation
Description
The product is a 7” Panel-PC based on Rockchip PX30 Cortex 35 chipset platform
with Android 10.
The central processor units include the CPU, DDR memory and flash.
The PX30 is the main application processor, and SAMSUNG 2GB DDR3 system memory
at PCBA. The SAMSUNG 16G eMMC is the system internal storage for OS or other
data. The wireless unit includes WIFI/BT. The 6221A-SRC module provides the
highest level of integration for a mobile or handheld wireless system with
integrated IEEE 802.11 a/b/g/n/ac standard and Bluetooth® 4.2 .
The panel-PC will starting up automatically when powered on, the panel PC will
display the boot up logo.
The system will discontinue transmission automatically and make the module
enter standby mode with no connection. It cannot send and receive any data to
preclude the transmission of control or signaling information or the use of
repetitive codes used by certain digital technologies to complete frame or
burst intervals.
Technical Specifications
WIFI Module
-
Operation frequency: 2.412 GHz ~ 2.462 GHz (2.4 GHz ISM Band), 5.180 GHz ~ 5.240 GHz, 5.745 GHz ~ 5.825 GHz (5.0 GHz ISM Band).
-
WLAN function: Supports 802.11a, 802.11b, 802.11g/n, 802.11ac
-
Modulation Type: Supports DBPSK/DQPSK/CCK(DSSS), BPSK/QPSK/16QAM/64QAM(OFDM), BPSK/QPSK/16QAM/64QAM/256QAM(OFDM)
-
Modulation type Transfer Rate (Mbps):
o 802.11a : 6, 12, 54Mbps
o 802.11b : 1, 11Mbps
o 802.11g : 6, 12, 54Mbps
o 802.11n: 6.5, 13, 19.5, 26, 39, 52, 58.5, 65Mbps -
Antenna Type: PCB
-
Gain: 1.3dBi for 2.4G and 1.3dBi for 5G. Bluetooth Features
-
Compliant with Bluetooth4.2 specification
-
Operation frequency: 2402MHz~2480MHz
-
Modulation Type: GFSK, π/4DQPSK, 8DPSK
-
Antenna Type: PCB
-
Gain: 1.3dBi
Crystal
Main board: 24MHz for CPU, 32.768KHz for PMU, 25MHz for PHY.
Technical Specifications
WIFI Module
www.mrsteam.com
Products, information and specifications are subject to change without notice.
Please call Technical Support at 1.800.76.STEAM (East Coast) or 1.800.72.STEAM
(West Coast) for more information.
The model and serial number is printed on the data plate on the front of the
steam bath generator.
Have this information available when contacting Technical Service.
mr.steam®
hello@mrsteam.com
www.mrsteam.com
References
- MrSteam Warranty Registration
- Home | Steam Shower Generators Controls Accessories | MrSteam