ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers User Manual

June 3, 2024
ELKAY

EZOOSTL8SC Series Sensor Operated
Versatile Bi Level Water Coolers
User Manual
ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water
Coolers

INSTALLER PLEASE NOTE:

IMPORTANT

This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler water ways. The grounding of electrical equipment such as telephones, computers, etc. to water lines is acommon procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materialsas noted below.

NOTICE
This water cooler must be connected to the water supply using a dielectric coupling – the cooler is furnished with a nonmetallic strainer which meets this requirement. The
drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building system.
Important
All Service to be performed by an authorized service person

  1. Insure proper ventilation by maintaining a clearance from cabinet louvers to wall on each side of cooler (see ROUGHIN in Cooler Manual for minimum clearance).

  2. Water supply 3/8” O.D. unplated copper tube. Waste 1-1/4” O.D. Contractor to supply waste trap and service stop valve in accordance with local codes.

  3. Connecting lines should be thoroughly flushed to remove all foreign matter before being connected to cooler. This cooler is manufactured in such a manner that it does not in any way cause taste, odor, color, or sediment problems. If a taste, odor or sediment problem is prevalent, try installing our water filter on the supply line (see
    Cooler Manual for part number).

  4. Connect 3/8” O.D. unplated copper water line from cooler to service. For Fountains with Remote Chillers, install a unionbetween the fountain valve and chiller. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS MAY RESULT.
    Note : Strainer not supplied on units with water filter. Simply insert 3/8” water line into fitting on filter head until a positivestop-approx. 3/4”.
    Note: If required, the 1/4” O.D. water inlet line from the strainer to the cooler may be cut to a desired length. However, if water line is cut, all burrs must be removed from outside of tube before inserting into the strainer.

  5. Electrical: Insure power supply is identical in voltage, cycle and phase to that specified on the cooler data plate. NEVER wire compressor directly to the power supply.

  6. The Manufacturer has glass fillers and glass filler plumbing kits specifically designed for use with several water coolers. Check local listings for a dealer near you.
    WARNING : Warranty is voided if: – The plumbing kit or glass filler is not specified for use by Manufacturer for this particular model.
    – Installation is not made in accordance with current Manufacturer instructions.

  7. These products are designed to operate on 20 to 105 psig supply line pressure. If inlet pressure is above 105 psig, a pressure regulator must be installed in supply line. Any damage caused by reason of connecting this product to supply line pressure lower than 20 psig or higher than 105psig is not covered by warranty.

  8. It is recommended that the drain trap, which is provided by the installer, be insulated to avoid excessive condensation due to chilled water running through the trap.
    START UP


  9. Turn on the building water supply and check all connections for leaks.

  10. Purge air from all water lines by depressing button or front push bar of cooler/fountain to which it is connected.
    Steady stream assures all air is removed. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, remove cover & button and adjust screw on regulator. Clockwise adjustment will raise stream and counter- clockwise adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2”(165mm) from bubbler.

  11. Recheck all water and drain connections with water flowing through system.

  12. Rotate fan to insure proper clearance and free fan action.

  13. Connect to electrical power.

  14. Replace the panel(s) and secure by retightening screws (see Cooler Manual for more information).
    TROUBLE SHOOTING & MAINTENANCE GUIDE

  15. BUBBLER: Mineral deposits on the orifice can cause water flow to spurt or not regulate. Mineral deposits may be removed from the orifice with a small round file not over 1/8” diameter or small diameter wire. CAUTION: DO NOT file or cut orifice material. Care must be taken not to damage the orifice(s).

  16. Stream Regulator: If orifice is clean, regulate flow as in “START UP” instructions above. If replacement is necessary, see parts list for correct regulator part number.

  17. WATER COMING OUT OF BUBBLER/PROJECTOR CONTINUOUSLY: When this occurs at the end of the compressor cycle, turn the cold control warmer (counterclockwise) 1/4 turn. Also, for cooler with press bars, see Cooler Manual-Water Valve MechanismADJUSTMENT PROCEDURE.

  18. Temperature Control: Factory set for 50°F water (+5°) under normal conditions. For colder water, adjust screw on cold control clockwise (see Cooler Manual).

  19. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with a brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.

  20. Lubrication: Motors are lifetime lubricated.

  21. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar before pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4” (19mm).

Note: Danger! Electrical shock hazard. Disconnect power before servicing unit.
Uses HFC-134A refrigerant
ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig1 Uses HFC-134A refrigerantELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water
Coolers - fig2

STANDARD ROUGH-IN FOR BI-LEVEL MODELS

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig3

LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3” (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2” OUT FROM WALL
C = 1-1/2” TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)

ALTERNATE INSTALLATON ROUGH-IN FOR BI-LEVEL MODELS

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig4 LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION 3/8” O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3” (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2” O.D. DRAIN STUB 2” OUT FROM WALL
C = 1-1/2” TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16” BOLT HOLES FOR FASTENING UNIT TO WALL
**NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTERS (GFCI)

Versatile Wrapper and Trim Kit Installation Instructions

Left Hand Wrapper
(High Side)

  1. Remove existing wrapperby removing the (4) screws from bottom.
  2. Screw trim piece to wrapper with (2) screws
    (provided
  3. Re-install wrapperwith (4) screws.
  4. Dispose of unused cover plate.| Right Hand Wrapper
    (Low Side)
  5. Remove existing wrapper  by removing the (4) screws  from bottom.
    2)Clip cover plate, sliding  until plate sits flush with
    the wall.
  6. Re-install  wrapper with  (4) screws.
  7. Dispose of  unused trim  piece.
    ---|---

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig5

Left Hand Wrapper
(Low Side)

  1. Remove existing wrapperby removing the (4) screws from bottom.
  2. Clip cover plate, slidinguntil plate sits flush with the wall.
  3. Re-install wrapper with(4) screws.
  4. Dispose of unused trim piece.| Right Hand Wrapper
    (High Side)
  5. Remove existing wrapper  by removing the (4) screws  from bottom.
  6. Screw trim piece to wrapper  with (2) screws (provided)
  7. Re-install wrapper with (4) screws.
  8. Dispose of unused cover plate.
    ---|---

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig6

HANGER BRACKETS INSTALLATION

  1. Remove hanger brackets fastened to back of cooler by removing one (1) screw.

  2. Mount the hanger brackets as shown in Figures 3, 4.
    NOTE : Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provideadequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.
    INSTALLATION OF COOLER

  3. Hang the cooler on the hanger bracket. Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figures 1, 2.

  4. Remove the four (4) screws holding the lower front panel at the bottom of cooler. Remove the front panel by pulling straight down and set aside.

  5. Connect water inlet line–See Note 4 of General Instructions.

  6. Install trap. Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap.
    Assemble the slip nut and gasket to the trap and tighten securely.
    IMPORTANT : If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.

  7. Plug in electrical power. Unit must have electrical power to have water flow.
    START UP
    Also See General Instructions

  8. Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust screw located on the right knee clearance area. CW  adjustmentwill raise stream and CCW adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2” (165mm) from bubbler on the downward slope of the basin.
    NOTE : If continuous flow occurs at the end of the compressor cycle, turn cold control counterclockwise 1/4 turn.

  9. Replace the front panel ensuring that the metal wrapper is secured inside of the upper shroud. Replace all four screws previously removed.

CLEANING

Warm, soapy water or mild household cleaning products can be used to clean the exterior panels of the EZ/LZ coolers. Extra caution should be used to clean the mirror finished stainless steel panels. They can be easily scratched and should only be cleaned with mild soap and water or Windex glass cleaner and a clean, soft cloth. Use of harsh chemicals or petroleum based or abrasive cleaners will void the warranty.

SENSOR RANGE ADJUSTMENT:

The electronic sensor used in this cooler is factory pre-set for a “visual” range of 36 inches (914 mm). If actual range varies greatly from this or a different set- ting is desired, follow the range adjustment procedure below:
– Using a small tip screwdriver, locate range adjustment screw through the small hole between the sensor lenses. Turn this screw clockwise to increase range and counterclockwise to decrease range (See Fig. 6).
CAUTION : Complete range of sensor (24-46 inches/610-1168mm) is only one turn of the adjusting screw.

SENSOR WITH VISUAL FILTER MONITOR (VFM) – LZO SERIES:

(For LZOOSTL8LC model – RH Cooler Unit only):
The electronic sensor includes LED filter status indicators that are factory preset to monitor filter life. The sensor monitors the “ON” time of the water valve solenoid and keeps track of total time water is dispensed. On LZOTL units, the sensor also monitors the water time on of the left hand unit using a yellow jumper wire. If the yellow jumper wire is not installed, improper water usage will be calculated. There are (3) LED’s and indicates the following:
Green LED (Good) indicates that the filter is operating within 0% – 80% of its life.
– Yellow LED indicates that the filter is operating within 80% – 100% of its life.
– Red LED (Replace) indicates that the filter needs to be replaced since it has reached end of filter life.
Once power is applied to the water cooler, if all three LED’s flash then the Green LED illuminates, this indicates that there is some filter usage memory stored. When the Green LED comes on only, this indicates that the filter life is at absolute 0% of filter life.
NOTE : You may have some very minimal filter life in memory upon receiving water cooler due to factory functional testing.
NOTE : The filter status will be retained until reset (see resetting filter monitor). The filter monitor will retain its memory even during a loss of power.

RESETTING VISUAL FILTER MONITOR (VFM):

In order to reset the visual filter monitor status LED’s, you must remove the access panel (item 14) underneath the front dispenser.
With your finger or straight blade screw driver, reach inside opening and depress the reset button located on the back of the sensor for a minimum of 1 second. (You may need a flashlight). Reinstall access panel and the Green LED should be illuminated indicating that the visual filter monitor has been reset.
SENSOR CONTROL: If sensor fails to operate valve mechanism or operates erratically, check the following.
A. Ensure there are no obstructions within a 40 inch(1016mm) radius in front of cooler.
B. Check wire connections at the solenoid valve and sensor.
CAUTION: Make sure unit is unplugged before checking any wiring.
C. Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water flows, look for an obstruction in the valve itself or elsewhere in the water supply line.

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig7

Service Instructions

Lower and Upper Shroud
To access the refrigeration system and plumbing connections, remove four screws from bottom of cooler to remove the lower shroud.
To remove the upper shroud for access to the pushbars, regulator, solenoid valve or other components located in the top of the unit, remove lower shroud, disconnect drain, remove four screws from tabs along lower edge of upper shroud, unplug two wires and water tube.
Bubbler
To remove the bubbler, first disconnect the power supply.
The underside of the bubbler can be reached through the access panel (Item 19, Page 2) on the underside of the upper shroud (Item 20, Fig.6 and 7). Remove the access panel by removing the retaining screw. To remove the bubbler, loosen locknut (See Fig. 8) from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions.
After servicing, replace the access panel and retaining screw.

*EZOOTL81A**ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level
Water Coolers - fig8

*EZOOTL81A**

NOTE:
When installing replacement bubbler and pedestal, tighten locknut only to hold parts snug in position. Do Not Overtighten.

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig10

WATERSENTRY®Filter Detail

WATERSENTRY® FILTER PARTS LIST

ITEM NO.| PART NO.| DESCRIPTION
1
2| 51299C
0000000895| Filter Assy-1500 Gal.
Assy-Filter & Bracket
includes Fltr Head/Mtg Bkt/ John Guest Ftgs/Screws

EZ-LZ Series 115V PARTS LIST

ITEM NO.| EZOOSTL8LC| LZOOSTL8LC| PART NO.| DESCRIPTION
---|---|---|---|---
1| x| x| 98724C| Kit – Evaporator Assy
2| x| x| 30873C| Jumper Wire (Black)
3| | x| 36264C| Jumper Wire (Yellow)
4| x| x| 55001109| Basin – Stainless Steel
5| x| x| 28401C| Hanger Bracket
‘6| x| x| 36322C| Compressor Serv. Pack
7| x| x| 36028C| Sensor – EE
8| | x| 36263C| Sensor – EE
9| x| | 56079C| Kit – Pushbar EZS(TL(L))
10| | x| 56282C| Push-Front EZ-EE VFM Gray
11| x| x| 56074C| Push-Filler EZO/LZO
12| x| x| 238| Kit – Elect/Overload/Relay/Cyr
13| x| x| 36285C| Power Cord (Refrig. Unit)
14| x| x| 31376C| Power Cord (Less Refrig. Unit)
15| x| x| 75583C| Kit – 75583C Elbow 5/16″ x 1/4
16| x| x| 1000004447| TL Waste Line
17| x| x| 56073C| Kit – Bubbler Assy/Nut
18| x| x| 56084C| Poly Tubing (Cut to Length)
| x| x| 55994C|
19| x| x| 27854K| Panel Wrapper
20| x| x| 56228C| Upper Shroud Assembly
21| x| x| 66703C| Drier
22| x| | 70682C| 1/4
Tee
23| x| x| 97969C| Kit – Drain Replace EZODTL
24| x| x| 55996C| In-Line Strainer
25| x| x| 1000004572| Kit – Solenoid Vlv/Regulator/Nut Assy.
26| x| x| 98773C| Kit – Cold Control/Screws
27| x| x| 98775C| Kit – Fan Motor Assy/Blade/Mtr/Shroud/
28| x| x| 3839700| Strain Relief
29| x| x| 98776C| Kit – Condenser/Drier
30| x| x| 98777C| Kit – Compr Mtg Hdwe/Grommets/Clips/Studs
31| x| | 98778C| Kit – Heatx/Drier
32| x| x| 97552C| Number Plate
33| x| x| 38417001| Screws/Nut
34| | x| 98368C| Number Plate
35| | x| 75710C| Screws/Nut
36| x| x| 1000004984| Kit – Drain Replace/Adapt/Tube/Ftg/Clamp
37| x| x| 1000004564| Kit – Regulator w/Holder & Nut
38| x| x| 98898C| Kit – Hardware (EZ) for Panels
NS| x| x| 28024C| Wrapper – Filler Stainless
NS| x| x| 28025C| Wrapper – Filler Light Grey
NS| x| x| 1000000888| Kit – EZTL Wrapper/Sery Label – Stainless (R)
NS| x| x| 1000000944| Kit – EZTL Wrapper/Sery Label – Light Grey (R)
NS| x| x| 1000000758| Kit – EZTLD Wrapper/Sery Label – Stainless (L)
NS| x| x| 1000000759| Kit – EZTLD Wrapper/Sery Label – Light Grey (L)

NS = NOT SHOWN X = Part Number Model Applicability
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE : All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.

ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers -
fig11

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
PRINTED IN U.S.A.
ELKAY MANUFACTURING Co
1333 BUTTERFLIED ROAD SUITE 200
DOWNERS GROVE, IL 60515 USA
630.574.8484
www.elkay.com
1000005928 (Rev. C – 07/21)

Documents / Resources

| ELKAY EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers [pdf] User Manual
EZOOSTL8SC Series Sensor Operated Versatile Bi Level Water Coolers, EZOOSTL8SC Series, Sensor Operated Versatile Bi Level Water Coolers, Versatile Bi Level Water Coolers, Level Water Coolers, Water Coolers
---|---

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals