ELKAY LZ Series Bottle Filling Station And Coolers User Manual

June 1, 2024
ELKAY

ELKAY LZ Series Bottle Filling Station And Coolers User Manual
ELKAY LZ Series Bottle Filling Station And Coolers User
Manual

REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDREN’S ADA COOLER

LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76mm) MAXIMUM OUT FROM WALL
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4″ O.D. DRAIN STUB 2 IN. OUT FROM WALL
C = 1-1/4″ TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX DUPLEX OUTLET
E = INSURE PROPER VENTILATION BY MAINTAINING 6” (152 mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16 BOLT HOLES FOR FASTENING UNIT TO WALL
NEW INSTALLATIONS MUST USE GROUND FAULT CIRCUIT INTERRUPTER (GFCI)
NOTE** : IT IS HIGHLY RECOMMENDED THAT THE CIRCUIT BE DEDICATED AND THE LOAD PROTECTION BE SIZED FOR 20 AMPS.

INSTRUCTIONS FOR REMOVING WRAPPER

  1. Remove the two security screws from the front panel. (see Fig B(i))
    NOTE: SCREW THREADS INTO BUSHING WHILE ANGLED. DO NOT ATTEMPT TO THREAD SCREW INTO BUSHING HORIZONTALLY.

  2. Gently pull the wrapper down and rotate the wrapper to a downward position (see Fig B(ii)).

  3. To remove the wrapper, hold each side and gently pull wrapper up and out of pivoting bracket (see Fig B(iii)).

CAUTION : WRAPPER DROPS AND SWINGS WHEN SECURITY SCREWS ARE REMOVED.
CAUTION : DO NOT LEAN ON WRAPPER.
CAUTION: DO NOT USE POWER TOOL TO TIGHTEN. DO NOT OVERTIGHTEN.

NOTE:

  1. Ensure that there are no plumbing or external objects below the wrapper in the specified dimension. The specified (3.27’’) minimum distance is required for the wrapper to swing out (see Fig B(iv)).
  2. Removing the wrapper from the pivoting bracket when servicing the unit is recommended. The wrapper may be left in place for quick serviceability ( see Fig B(iii)).
  3. When re-attaching wrapper, ensure each side of wrapper is engaged to pivoting bracket (see Fig B(v)).
  4. Once the wrapper is in place, rotate wrapper up and under the shroud. Ensure thru holes on wrapper are aligned with plastic bushing threads on the frame prior to engaging security screws. Ensure screw is angled relative to the ground and perpendicular to wrapper surface prior to engagement. Hand tighten prior to using hand tool to avoid cross-threading.
  5. Four plastic bushings are located in the cross brace of the frame. The lower two bushings align with wrapper holes and the top two bushings are extras in case of replacement (see Fig B(iii)).

Documents / Resources

| ELKAY LZ Series Bottle Filling Station And Coolers [pdf] User Manual
LZS8WSSP-PF, LZ Series Bottle Filling Station And Coolers, LZ Series, Bottle Filling Station And Coolers, Filling Station And Coolers, Station And Coolers, Coolers
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals