*Versatile cooler design allows units to be installed either left-hand high and right-hand low or left-low and right high.
Basin change may be required. See desired rough-in to help determine if the basin change is necessary.
Important: The refrigerated coolers must be hung on the right side.
Patent zurn-elkay.com/patents
WARNING:
Cancer and Reproductive Harm – www.P65Warnings.ca.gov
STANDARD ROUGH-IN FOR LEFT -HAND HIGH, BOTTLE FILLER LOW MODELSELKAY
ENLZSTL8WS-W1 TM Series Bottle Filling Stations Coolers - fig
1 REDUCE HEIGHT BY 3 INCHES FOR INST ALLA TION OF CHILDREN’S ADA COOLER
LEGEND

A  = RECOMMENDED W A TER SUPPL Y  LOCA TION 3/8 O.D. UNPLA TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY  OTHERS) 3 IN. (76 mm ) MAXIMUM OUT FROM W ALL

B = RECOMMENDED LOCA TION FOR W ASTE OUTLET 1-1/2″ O.D. DRAIN STUB 2 IN. OUT FROM W ALL

C = 1-1/2″ TRAP  NOT FURNISHED

D = ELECTRICAL SUPPL Y (3) WIRE RECESSED BOX DUPLEX OUTLET
E = INSURE PROPER VENTILA TION AND ADA COMPLIANCE BY MAINT AINING 6″ (152 mm ) (MIN.) CLEARANCE FROM CABINET LOUVERS T O W ALL.
F = 7/16 BOL T HOLES FOR F ASTENING UNIT T O W ALL
NEW INST ALLA TIONS MUST USE GROUND F AUL T CIRCUIT INTERRUPTER (GFCI)
NOTE: It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps and utilze hospital-grade GFCI.
AL TERNA TE ROUGH-IN FOR RIGHT -HAND HIGH, BOTTLE FILLER LOW MODELS – REQUIRES BASIN ASSY CHANGEELKAY ENLZSTL8WS-W1 TM Series Bottle Filling
Stations Coolers - fig2 REDUCE HEIGHT BY 3 INCHES FOR INST ALLA TION OF CHILDREN’S ADA COOLER
LEGEND
A = RECOMMENDED W A TER SUPPL Y LOCA TION 3/8 O.D. UNPLA TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76 mm ) MAXIMUM OUT FROM W ALL
B = RECOMMENDED LOCA TION FOR W ASTE OUTLET 1-1/2″ O.D. DRAIN STUB 2 IN. OUT FROM W ALL
C = 1-1/2″ TRAP NOT FURNISHED
D = ELECTRICAL SUPPL Y (3) WIRE RECESSED BOX DUPLEX OUTLET
E = INSURE PROPER VENTILA TION AND ADA COMPLIANCE BY MAINT AINING 6″ (152 mm ) (MIN.) CLEARANCE FROM CABINET LOUVERS T O W ALL.
F = 7/16 BOL T HOLES FOR F ASTENING UNIT T O W ALL
NEW INST ALLA TIONS MUST USE GROUND F AUL T CIRCUIT INTERRUPTER (GFCI)
NOTE: It is highly recommended that the circuit be dedicated and the load protection be sized for 20 amps and utilze hospital-grade GFCI.
AL TERNA TE ROUGH-IN FOR LEFT -HAND LOW , BOTTLE FILLER HIGH MODELSELKAY ENLZSTL8WS-W1 TM Series Bottle Filling Stations Coolers - fig
3 REDUCE HEIGHT BY 3 INCHES FOR INST ALLA TION OF CHILDREN’S ADA COOLER

LEGEND
A = RECOMMENDED W A TER SUPPL Y LOCA TION 3/8 O.D. UNPLA TED COPPER TUBE CONNECT STUB WITH SHUT OFF (BY OTHERS) 3 IN. (76 mm ) MAXIMUM OUT FROM W ALL
B = RECOMMENDED LOCA TION FOR W ASTE OUTLET 1-1/2″ O.D. DRAIN STUB 2 IN. OUT FROM W ALL
C = 1-1/2″ TRAP NOT FURNISHED
D = ELECTRICAL SUPPL Y (3) WIRE RECESSED BOX DUPLEX OUTLET
E = INSURE PROPER VENTILA TION AND ADA COMPLIANCE BY MAINT AINING 6″ (152 mm ) (MIN.) CLEARANCE FROM CABINET LOUVERS T O W ALL.
F = 7/16 BOL T HOLES FOR F ASTENING UNIT T O W ALL
NEW INST ALLA TIONS MUST USE GROUND F AUL T CIRCUIT INTERRUPTER (GFCI)
ALTERNATE ROUGH-IN FOR RIGHT -HAND LOW , BOTTLE FILLER HIGH MODELS – REQUIRES BASIN ASSY CHANGEELKAY ENLZSTL8WS-W1 TM Series Bottle Filling
Stations Coolers - fig 4 REDUCE HEIGHT BY 3 INCHES FOR INST ALLA TION OF CHILDREN’S ADA COOLER

WRAPPER REMOVAL INSTRUCTIONS

ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(5\)

  1. Remove the two security screws from the front panel. (see Fig D(i)).
    NOTE  : SCREW THREADS INTO BUSHING WHILE ANGLED. DO NOT ATTEMPT TO THREAD SCREW INTO BUSHING HORIZONTALLY.

  2. Gently pull the wrapper down and rotate the wrapper to a downward position (see Fig D(ii).

  3. To remove the wrapper, hold each side and gently pull the wrapper up and out of the pivoting bracket (see Fig D(iii)).ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers- \(6\)

CAUTION: WRAPPER DROPS AND SWINGS WHEN SECURITY SCREWS ARE REMOVED.
CAUTION: DO NOT LEAN ON WRAPPER.
CAUTION: DO NOT USE POWER TOOL TO TIGHTEN. DO NOT OVERTIGHTEN.

NOTE

  1. Ensure that there are no plumbing or external objects below the wrapper in the specified dimension. The specified (3.27’’) minimum distance is required for the wrapper to swing out (see Fig D(iv)).
  2. Removing the wrapper from the pivoting bracket when servicing the unit is recommended. The wrapper may be left in place for quick serviceability (see Fig D(iii)).
  3. When re-attaching wrapper, ensure each side of wrapper is engaged to pivoting bracket (see Fig D(v)).
  4. Once the wrapper is in place, rotate wrapper up and under the shroud. Ensure thru holes on wrapper are aligned with plastic bushing threads on the frame prior to engaging security screws. Ensure screw is angled relative to the ground and perpendicular to wrapper surface prior to engagement. Hand tighten prior to using hand tool to avoid cross-threading.
  5. Four plastic bushings are located in the cross brace of the frame. The lower two bushings align with wrapper holes and the top two bushings are extras in case of replacement (see Fig D(iii)).

8NOTE:
The visible part of the red color is the recommended plumbing for installation.
NOTE
In order to reduce the disturbance of the circulation, zip ties (pipes and electricity) run between the cooling units to the waste line (PVC pipe).

HANGER BRACKETS INSTALLATION

  1. Remove hanger bracket fastened to back of coolers by removing one (1) screw.

  2. Determine your mounting configuration from the figures shown on pages 2 – 5. Refrigeration unit must be on right hand side.
    IMPORTANT NOTE: If the Bottle Filler is to be mounted on the left hand cooler, a basin assembly change will be needed.
    Determine your configuration by referring to the Configuration Instructions on page 10 prior to continuing.

  3. Mount the hanger bracket as shown in Figures 1 – 4 (Pages 2 – 5).
    NOTE: Hanger Bracket MUST be supported securely. Add fixture support carrier if wall will not provide adequate support. Anchor hanger securely to wall using all six (6) 1/4 in. dia. mounting holes.
    IMPORTANT: 5-7/8 in. (150 mm) dimension from wall to centerline of trap must be maintained for proper fit.

INSTALLATION OF COOLER

  1. Refer Fig D(i) to D(iv), Pg. 6 for wrapper removing instructions.

  2. Hang only the refrigerated cooler on the hanger bracket. Be certain hanger bracket is properly in the slots on the cooler backs as shown in Figures 1 (Pg. 2), 2 (Pg.3), 3 (Pg. 4), and 4 (Pg. 5).

  3. Hang the non-refrigerated cooler on the hanger bracket. Be certain hanger bracket is engaged properly in the slots on the cooler backs as shown in Figures 1 (Pg. 2), 2 (Pg. 3), 3 (Pg. 4), and 4 (Pg. 5).

  4. Unband the loose wires in the refrigerated cooler for the filter communication board. Stretch it out and thread through the left side of the refrigerated cooler and into the right side of the non-refrigerated cooler. Plug into the filter communication board that is behind the filter head.

  5. Secure each cooler frame to wall by installing (2) screws and washers (not supplied) in lower holes. See pictures below.
    Make sure the screws engage in a structural member.ELKAY-
ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(8\)

  6. Connect the supply water to the filter 3/8” copper inlet tube.

  7. Connect the waterline from the outlet of the filter to the inlet of the evaporator in the refrigerated cooler by inserting it into the quick connector.

  8. Connect the waterline from the solenoid in the non-refrigerated cooler to the open 1/4” inch tee fitting in the refrigerated cooler. Ensure line is completely inserted into the fitting.

  9. Find your cooler configuration on page 11 and connect the drain assembly together.

  10. Install trap.
    IMPORTANT: If it is necessary to cut the drain, loosen the screw at the black rubber boot and remove tube, check for leaks after re-assembly.

BOTTLE FILLER INSTALLATION

  1. Remove two (2) mounting screws with 5/32” Allen wrench holding Bottle Filler to wall mounting plate (See Fig. 8). Note do not discard mounting screws, they will be needed to secure Bottle Filler to wall mounting plate.

  2.  Remove wall mounting plate from Bottle Filler (See Fig. 8 ). Place wall mounting plate against wall on top of basin. Center the wall mounting plate side to side with the basin. Mark the six (6) mounting holes with a pencil (See Fig. 1, Pg. 2). Place tape over wiring harness connection on top of cooler to prevent debris from falling into Connection(See Fig. 6, Pg. 7).

  3. Remove wall mounting plate from wall.
    NOTE: Mounting plate MUST be supported securely. Add fixture support carrier if wall will not provide adequate support.

  4. Install wall mounting plate to wall using six (6) 7/16” obround mounting holes (mounting bolts not included) (See Fig. 7, Pg. 7). Use appropriate fasteners for your wall type.

  5. Install gasket on bottom of Bottle Filler with gasket support bracket & (2) screws. (See Fig. 8).

  6. Route 3/8” tubing through the opening in the bottle filler gasket and plug into bulkhead fitting in basin. Route the wiring harness through the gasket and plug into the connector on the top of the basin. Water line should be cut to length prior to attaching to bulkhead fitting.

  7. Place Bottle Filler on the four (4) hooks on the mounting plate installed on wall.ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers- \(10\) ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers- \(11\)FINAL INSTALLATION (FILTER)

  8. Remove filter from carton, remove protective cap, attach filter to filter head by firmly inserting into head and rotating filter clockwise. Ensure that filter label can be read when filter is installed. (See Fig. 12)

  9. Turn water supply on and inspect for leaks. In both cooler and Bottle Filler. Fix all leaks before continuing.

  10. Once cooler and bottle filter have been inspected for leaks and any leaks corrected, plug cooler into wall.

  11. Reinstall two mounting screws from first step above. Caution do not over tighten screws.

  12. Once power is applied to the cooler the GREEN LED light will illuminate on the bottle filler showing good filter status along with the LCD Bottle Counter.

  13. Verify proper dispensing by placing cup, hand, or any opaque object in front of sensor area and verify that the water dispenses. Note: the first initial dispenses might have air in line which may cause a sputter and hazy appearance. Run water and flush filter (refer to step 8 below). This will be eliminated when all air is purged from the line.

  14. Once unit tests out, install Lower Panels back on water coolers. (See pages 12-13 for versatile wrapper installation).

  15. When re-attaching wrapper, push wrapper up and under the shroud. Make sure wrapper and bushing holes are aligned prior to inserting screw. Units are now ready for use.

INSTRUCTIONS FOR REPLACING FILTERS

  1. Refer Fig D(i) to D(iv), Pg. 6 for wrapper removing instructions.
  2. Turn off water supply; dispense water to relieve pressure.
  3. Remove power by unplugging cooler.
  4. Turn used filter counterclockwise 1/4 turn to remove from filter head.
  5. Remove cap from new filter and use to seal used filter.
  6. Insert new filter into existing filter head and turn fully clockwise. Make sure you can read the label on the front of the filter once it is installed. (See Fig. 12).
  7. Plug in unit to restore power.
  8. Turn on water supply and Run water and flush filter to purge air and fine carbon particles from filter before use. Visit elkay.com/filtration for additional details. Also run water through bottle filler until all air is removed and water flow is clear.
    Note: Filter status light will automatically reset once new filter is installed.

INSTRUCTIONS TO ACCESS PROGRAMMING BUTTON

  1. Remove the bottom cover of the refrigerator by removing (2) screws.
  2. The button is located on the lower right side of the unit (See Fig. 13).ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers- \(13\)

CONFIGURATION INSTRUCTIONS
INSTRUCTIONS TO MOVE THE BOTTLE FILLER & BASIN TO THE LEFT SIDE (NON- REFRIGERATED) FOR ALTERNATE MOUNTING VERSATILE BI-LEVELELKAY-
ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(14\)ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(15\)

  1. Refer Fig D(i) to D(iv), Pg. 6 for wrapper removing instructions.

  2. Remove the filter panel from the cooler using a 5/16” socket.

  3. Using a T25 (6-point star) screwdriver, loosen the fabric screws on both sides of the cooler.

  4. Lift the connecting basin/cloth to each cooler. Connect the water line from the solenoid and the cloth wire from the wire to the solenoid. Set aside.

  5. Unfasten the electrical harness connector from the electrical bracket.
    Using a T25 (6-point star) bit, remove the electrical bracket from the mounting bracket. Snap the electrical harness connector into the cutout of the mounting bracket with the connector facing down. (See Fig. 14.)

  6. Install the electrical bracket on the filter bracket of the non-refrigerated cooler by removing the two screws towards the front of the cooler and reinstalling them through the bracket. Attach the female end of the bi-level extension into the electrical bracket.

  7. Only move the filter panel and J-clip to the refrigerated (right) cooler if the right side will be mounted high.

  8. Install the non-bottle fi ller basin on the refrigerated cooler. Connect the water line to the solenoid and the electrical connections to the wiring harness and solenoid. Tighten the (4) T25 screws.

  9. Install the coolant on the right hanger bracket. Secured to the wall.

  10. Install the bottle filler basin on the non-refrigerated cooler. Connect the water line to the solenoid and the electrical connections to the wiring harness and solenoid. Be sure the electrical connector is protruding through the cutout in the top of the basin. Tighten the (4) T25 screws.

  11. Install the non-refrigerator on the left side bracket. Secured to the wall.

  12. Run the bi-level extension through the cooler and connect it to the refrigerator power cord that is placed in the mounting bracket (See Fig. 15 & 16).ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers- \(17\)

  13. Hook up the drains using the attached drain kit.

  14. Make all water and electrical connections.

  15. Reinstall wrappers using (2) screws for each wrapper.

Refrigerated Cooler side:

ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(18\)

Non-Refrigerated Cooler sideELKAY-ENLZS Swap drain parts in shroud: Loosen each hose clamp retaining the drain pieces. Remove each drain piece and swap to another basin.
Tighten each hose clamp.
Additional EZH2O Error Codes

Error Code Error Description Corrective Action
Please clear Bottle Filler • Remove obstruction

• Clean lens on IR sensor
• Unplug unit for at least 30 seconds and restart
• If error repeats, replace IR sensor
E013| Missing or Incompatible Filter| • Check that filter is installed correctly (label facing forward, round blue tag facing NFC Board)
• Unplug unit for at least 30 seconds and restart
• Replace filter
• Replace filter head assembly with repair kit
• If error repeats, contact certified service professional
EO13 &  EO14| Missing/Unplugged NFC ,Board| • Unplug unit for at least 30 seconds and restart
• Verify cable connector is plugged into NFC board on filter head assembly
• Replace filter head assembly with repair kit
• If error repeats, contact certified service professional

PLUMBING DIAGRAMS VERSATILE BI-LEVELELKAY-ENLZSTL8WS_1G_PIVOT-TM-
Series-Bottle-Filling-Stations-and-Coolers- \(20\)ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-
Filling-Stations-and-Coolers- \(21\)

Versatile Wrapper and Trim Kit Installation Instructions

Left Hand Wrapper (High Side)

  1. Remove the (2) screws from the wrapper, rotate the wrapper down, and remove.
  2. Screw trim piece to wrapper with (2) screws (provided).
  3. Re-install wrapper with (2) screws.
  4. Dispose of unused cover plate.

ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(22\)

Right Hand Wrapper (Low Side)

  1. Remove the (2) screws from the wrapper, rotate the wrapper down, and remove.
  2. Clip cover plate, sliding until plate sits flush with the wall.
  3. Re-install wrapper with (2) screws.
  4. Dispose of unused trim piece.

Wrapper Fill Piece Location
(Left Side High)ELKAY ENLZSTL8WS-W1 TM Series Bottle Filling Stations
Coolers - fig 5

Left Hand Wrapper (Low Side)

  1. Remove the (2) screws from the wrapper, rotate the wrapper down, and remove.
  2. Clip cover plate, sliding until plate sits flush with the wall.
  3. Re-install wrapper with (2) screws.
  4. Dispose of unused trim piece.ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers- \(25\)

Right Hand Wrapper (High Side)

  1. Remove the (2) screws from the wrapper, rotate the wrapper down, and remove.
  2. Screw trim piece to wrapper with (2) screws (provided)
  3. Re-install wrapper with (2) screws.
  4. Dispose of unused cover plate.

ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(26\) 115V Refrigerated Wiring Diagram with Alpha/Numeric Display Connect- Ready – Enhanced Bottle FillerELKAY ENLZSTL8WS-W1 TM Series Bottle Filling
Stations Coolers - fig 6 OPERATION OF QUICK CONNECT FITTINGS
ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(28\) NOTE
When installing the bubbler and pedestal, secure the nut so that the parts do not move. Do not add.
Scan for trouble shooting and to sign up for auto replenishment of authentic Elkay filters.https://www.elkay.com/qr/subscribe

ELKAY ENLZSTL8WS-W1 TM Series Bottle Filling Stations Coolers - fig
7

WATERSENTRY®Filter Detail
WATERSENTRY® FILTER PARTS LIST

Service Instructions

  • Bottom and Top Cover
    To access the refrigerator and connecting pipes, remove the two (2) screws on the front of the cooler to remove the bottom cover. To remove the upper cover to access the pushbars, regulator, solenoid valve or other components on the top of the unit, remove the lower cover, remove the drain, remove the four screws on the tabs on the lower edge of the upper cover, remove two wires and water. tube.

  • Bubbler
    To remove the bubbler, first disconnect the power supply. The underside of the bubbler can be reached through the access panel on the underside of the upper shroud. Remove the access panel by removing the retaining screw. To remove the bubbler, loosen the locknut from the underside of the bubbler and remove the tubing from the quick connect fitting per the Operation Of Quick Connect Fittings section in the General Instructions. After servicing, replace the access panel and retaining screw.

Switches Behind the Push Bar
The regulator in an EZ cooler is always held fully open by the use of a single regulator nut.
Water is not dispensed until the pushbar is depressed to activate a switch which then opens a solenoid valve.
To remove sidebars, from the inside compress the fl ared tabs and pull out carefully. To reinstall side pushbars, the front of the pushbar is inserted fi rst. While keeping the switch depressed, snap the rear of the pushbar into position.

Cleaning

ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-Filling-Stations-and-Coolers-
\(31\)

Stainless steel

  • General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
  • Steel soap pads should never be used; particles can adhere to a stainless steel basin surface and will eventually rust.
  • Light scratches are normal for stainless steel basins; over time they will blend into the uniform fi nish pattern.
  • Do not use cleaners containing acids or chlorides, these will cause the stainless steel to oxidize.

Plastic Components

  • General cleaning: use an ordinary mild detergent and soft cloth, rinse and towel dry.
  • Wiping the surface clean to remove debris or build up will not hurt the antimicrobial properties.

Temperature Control
Factory set at 50°F (+/- 5°F) under normal conditions. To change the ladder, see the stickers on the left side of the bar.
Stream Height Adjustment
VIEW OF UNDERSIDE OF BASIN SHROUDELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-
Bottle-Filling-Stations-and-Coolers- \(32\)ELKAY-ENLZSTL8WS_1G_PIVOT-TM-Series-Bottle-
Filling-Stations-and-Coolers- \(33\) Programming Instruction

Pictured is unit only without bottle filler.
Note: Danger! Electrical shock hazard. Disconnect power before servicing unit.ELKAY ENLZSTL8WS-W1 TM Series Bottle Filling Stations Coolers - fig
8 ATTENTION:
If the product serial number is before 190424189, please refer to archived documents section of Elkay.com for the most accurate parts list. (www.elkay.com/archived-documents)
115V PARTS LIST

ITEM NO. PART NO. DESCRIPTION

1
2A
2B
3
*4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28A
28B
29
30
NS
NS
NS
NS| 28401C
55001109
0000001337
36216C
36322C
56092C
56229C
66703C
56213C
1000004572
1000004564
56073C
98734C
1000001600
35980C
1000004568
98775C
98776C
98777C
98778C
98898C
0000000238
98724C
1000001602
1000004547
1000004550
1000004559
1000004447
98900C
97969C
1000001812
98773C
2000001267
2000001274
28024C
28025C
1000001892
1000001891
1000001894
1000001893| Hanger Bracket
Basin – Stainless Steel
Basin – Bottle Filler Stainless Steel
Wiring – Front/Side Push Bar
Compr – Service Pak 115V EMIS70HHR
Tube – Poly (Cut To Length)
Assy – Shroud – Upper (Front Side Push)
Drier
Access Panel
Kit – Solenoid Valve/Regulator Assembly
Kit – Regulator W/Holder & Nut
Replacement Bubbler Assy
Kit – Pushbar (Front/Side) TL
Kit – Pushbar (Front Only)
Power Cord Non-Refrigerated
Power Cord – EZTL8
Kit – Fan Motor/Blade/Screws/Nut
Kit – Condenser/Drier/WireTies
Kit – Compr Mtg Hdwe/Grommets/
Clips/Studs
Kit – Heatx/Drier
Kit – Hardware
Kit – 115V Electricals (Relay, Ovrld, Cover)
Kit – Evap. Replacement
Kit – 75583C Elbow 5/16″ x 1/4″ (3 Pack)
Harness – Cooler
Wire – 6” Jumper
Wire Assy – Jumper
Wasteline Drain Assy
Kit – Drain Replace TL
Kit – Drain Replace (TL) LR
Kit – Bottle Filler Drain
Kit – Cold Control
Kit – Drop Down Wrapper Stainless TL
Kit – Drop Down Wrapper Stainless LZTLD
Filler – Wrapper Light Grey LZTLD
Filler – Wrapper Stainless LZTLD
Bracket – Trim Strip Light Grey LZTLD
Bracket – Trim Strip Stainless LZTLD
Panel – Universal Trim Light Grey LZTLD
Panel – Universal Trim Stainless LZTLD

NS = Not Shown
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST2  include Model No. and Serial No. of cooler, name and part number of replacement part.

BOTTLE FILLER REPLACEMENT PART KITS

ITEM NO. PART NO. DESCRIPTION

NS
31
32
NS
33
34
35
NS
36
37
38| 98546C
98549C
1000004573
1000005077
1000002433
1000005219
2000000832
1000004436
1000004546
1000004549
1100000025| Kit – Aerator Replacement
Kit – Hardware & Waterway (BF)
Kit – Solenoid Valve 120V (BF)
Nameplate – Elkay Filtered
Kit – Top Cover Assy (BF)
Kit – IR Sensor K+
Kit – Alpha Numeric LED Board (Connected Ready)
Kit – Tower/Basin Gasket
Harness – Bottle Filler
Harness – LED/IR Board
End-point Board Service Kit

Register in plumbSMART

  1. Install Zurn Gateway (required and sold separately) per the gateway instructions manual, if an existing gateway is not within communication range.
  2. If you have not already set up an enterprise account and your administrator access, Zurn creates your Enterprise Account for you! (you will be required to identify your building location, number of floors, and number of rooms.) and request plumbSMART administrator account at 844-987-6737.
  3. Log into plumbsmart.zurn.com
  4. Register each Connected product in plumbSMART (Watch How-To videos to get started. Located in the support section inside the portal.)

Note: Refer to the plumbSMART Registration ID label (See Fig. 11a, Pg. 8).

FCC COMPLIANCE STATEMENT

CA U TI O N: Changes or modifications not expressly approved could void your authority to use this equipment This device complies with Part 15 of the FCC Rules. Operation to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.
INDUSTRY CANADA STATEMENT
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.
The device shall be used in such a manner that the potential for human contact normal operation is minimized. This equipment complies with RSS-102 radiation exposure limits. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body. This device and its antenna(s) must not be co-located or operating in conjunction with any other antenna or transmitter.

FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
REPAIR SERVICE INFORMATION TOLL FREE NUMBER 1.800.260.6640
PRINTED IN U.S.A.
ELKAY MANUFACTURING Co.
1333 BUTTERFLIED ROAD SUITE 200
DOWNERS GROVE, IL 60515 USA
630.574.8484
www.elkay.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals