BEGA 13 620 Electronic Power Supply Unit

DIMENSION

Specifications

  • Product Name: Electronic Power Supply Unit
  • Output: 100 W for 48 V DC LED luminaires
  • Material: Aluminium alloy, aluminium, and stainless steel
  • Safety Class : I
  • IP Rating: IP65

Product Description

The electronic power supply unit is designed with an output of 100 W for 48 V DC LED luminaires. It is constructed using a combination of aluminium alloy, aluminium, and stainless steel, ensuring durability and protection.

Usage Instructions

Safety Precautions

Installation and commissioning must be done by a qualified electrician. Ensure compliance with national safety regulations to prevent damage or hazards. The manufacturer does not accept liability for improper use or modifications.

Installation Steps

  1. Securely mount the power supply unit using appropriate mounting materials on a suitable surface.
  2. Establish the protective earth connection.
  3. Make electrical connections to the terminals marked with ‘L’ and ‘N’. Use the terminals labelled ‘DA’ for digital control.
  4. If the ‘DA’ terminals are not used, connect to the marked terminals ’48V +’ and ’48V -‘, ensuring correct polarity.
  5. Tighten all cable glands securely.

Instructions for use

Application

  • Electronic power supply unit with an output of 100 W for 48 V DC LED luminaires.
  • The power supply unit is suitable for the operation of multiple LED luminaires.
  • Please note the maximum output of the power supply unit here.

Product Description

Power supply unit box made of aluminium alloy, aluminium and stainless steel

  • 2 mounting holes ø 6.5 mm

  • Distance apart 210 x 62 mm

  • 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@

  • 4 screw cable glands with strain relief

  • for connecting cables ø 5–13 mm

  • Complies with flicker requirements by IEEE 1789,

  • DIN IEC/TR 63158, DIN IEC/TR 61547-1

  • LED power supply unit

  • 220-277 V 0/50-60 Hz

  • DC 190-250 V

  • DALI-controllable

  • Number of DALI addresses: 1

  • Basic insulation is provided between the mains and control cables

  • Primary:

  • AC: 90-305 V  50/60 Hz

  • DC: 127-420 V

  • 4 loose connectors 3-pole, max. 4 mm² Terminal configuration

  • L · N · DA · DA

  • Earth conductor connection
    Secondary:

  • 48 V = DC · 0-100 W

  • Connecting terminal

  • Terminal configuration

  • 48 V + · 48 V –

  • Safety class I

  • Protection class IP 65

  • Dust-tight and protection against water jets
    CE – Conformity mark

  • Weight: 2.0 kg

Safety

  • The installation and operation of this power supply unit is subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation. Should the power supply unit be subsequently modified, the persons responsible for the modification shall be considered the manufacturer.

Installation

  • Undo the screws and remove the cover from the connection housing.
  • Fix the power supply unit with enclosed or any other suitable fixing material onto the mounting surface. It is essential to use the enclosed ring gaskets.
  • Lead mains supply cable through the screw cable gland/compression nipple.
  • Make an earth conductor connection.
  • Make electrical connections at the loose connectors marked with L and N.
  • The two connecting terminals marked DA, and DA are provided for digital control purposes.
  • If these terminals are not assigned, the luminaire will work with full light output. Luminaire – lead connecting cable through the screw cable gland and make the electrical connection on the marked connecting terminals 48 V + and 48 V – .
  • Make sure that the poles are connected correctly.
  • Tighten screw cable glands.

Please note

  • Screw cable glands not used must be closed with the delivered dummy plugs.
  • LED-power supply units must not be installed in heat-insulating material.
  • Make sure that the gasket is positioned correctly. Make an earth conductor connection to the connection housing (plug connection) and assemble the cover onto the connection housing. Please note that the earth conductor lead are not jammed between cover and

Spares

  • DLED power supply unit: DEV-0499/48V
  • DALI/PWM-module 48 V: 61 002 176
  • Gasket: 83 001 660

FAQ

  • Q: Can the power supply unit be installed in outdoor locations?
    • A: Yes, the power supply unit has an IP65 rating, making it suitable for outdoor use where it is protected from direct exposure to water.
  • Q: What should I do if I need replacement parts?
    • A: For replacement parts such as the LED power supply unit DALI/PWM module or gaskets, refer to the provided part numbers for ordering.