levenhuk NG60 Gas Detector User Manual

June 1, 2024
levenhuk

levenhuk-logo

levenhuk NG60 Gas Detector

levenhuk-NG60-Gas-Detector-product-image

Product Information

Specifications:

  • Brand: Ermenrich
  • Model: NG60 Gas Detector
  • Includes: gas detector, USB cable, charging adapter, aluminum carry case, user manual, warranty

Product Usage Instructions

  • Charging the Device:
    Always turn off the device before charging. Do not charge in potentially explosive atmospheres.

  • Getting Started:
    Press and hold the power button (5) for 3 seconds to turn the device on/off. The device will perform a self-check and display preset information.

  • Settings:
    Press the power button (5) to enter the menu, navigate using lefm (4) and right (6) buttons. Set time, date, battery status, and a password.

  • Zero Adjustment:
    Not specified in the provided text.

  • Alarm Records:
    View or clear previous alarm records in the menu. Use lefm (4) and right (6) buttons to manage records.

  • Usage :
    The device is set to gas detection mode by default. It will analyze the gas environment and display results on the screen.

Gas Types and Detection Range:

  • Oxygen: Low alarm 19.5
  • Methane: Low alarm 1.00
  • Carbon monoxide: Low alarm 50
  • Hydrogen sulfide: Low alarm 10
  • Combustible gas: Low alarm 20
  • Ammonia: Low alarm 20
  • Hydrogen: Low alarm 200
  • Chlorine gas: Low alarm 5
  • Hydrogen chloride: Not specified
  • Sulfur dioxide: Not specified
  • Nitric oxide: Not specified
  • Nitrogene dioxide: Not specified
  • Carbon dioxide: Not specified
  • Hydrogen phosphide: Not specified
  • Hydrogen cyanide: Not specified
  • Epoxy acetylene: Not specified

Frequently Asked Questions (FAQ):

  • Q: How do I charge the device?
    A: Always turn off the device before charging it. Use the provided USB cable and charging adapter for charging.

  • Q: How do I view previous alarm records?
    A: Navigate to the Alarm Rec section in the menu using the lefm (4) and right (6) buttons to view or clear alarm records.

  • Q: What should I do if the gas concentration is abnormal?
    A: If the gas concentration exceeds the alarm value, the device will alert you with LED indicators, vibrations, beeping sounds, and display the current detection value on the screen. Take necessary precautions and follow safety protocols.

Ermenrich NG60 Gas Detector
User Manual

Overview

  • 1,2,3 LED indicators
  • 4 Left button
  • 5 Power button
  • 6 Right button
  • 7 Gas-sensing hole
  • 8 Power input
  • 9 LCD screen

Ermenrich NG60 Gas Detector

  • Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.
  • The kit includes: gas detector, USB cable, adapter for charging, aluminum carry case, user manual, and warranty.

Charging the device

  • This device uses a rechargeable Li-ion battery. Connect the power cable to the device and the DC adapter via a USB plug and connect it to the AC power supply to charge the device.
  • Fully charge for 6–8 hours. For fast charging, turn the device off. Working battery time is 16–18 hours.
  • Always turn off your device before charging it. Do not charge the device in potentially explosive atmospheres.

Getting started

  • Press the power button (5) and hold it for 3 seconds to turn the device on/off.
  • The device will start the self-check: the LED indicators will blink twice, the device will emit a short vibration signal and then will beep twice. After the self-check, the device will display the preset information for low alarm value, high alarm value, and the detection range upper limit value for combustable gas, oxygen, hydrogen sulfide and carbon monoxide in sequence.

Settings

  • Press the power button (5) to enter the menu, to enter a submenu, to confirm the selection, and to save changes. Press the left (4) and right (6) buttons to scroll through the menu.
  • You can view and set the time and date, and you can view the battery status.
  • You can set a 4-digit password to prevent the device from accidental operation.

Zero adjustment

  • You can adjust the zero setting according to the actual detection value.
  • Enter the zero trim submenu, select the gas type, the value, and unit of measurement. Then, save the adjusted value.
  • For example, if the displayed value is 3 instead of 0, you can set –0004 and save this value: after that the displayed detection value will be 0.

Alarm records

You can view or clear the previous alarm records in the Alarm Rec (Alarm records) section of the menu.

  • Alarm records view
    To switch between records, press left (4) and right (6) buttons.

  • Alarm records deletion
    To clear the alarm value, press the left button (4) and select OK. To cancel deletion, press the right button (6) and select Quit (Cancel).

Usage

Gas detection mode is set by default. The system returns to the gas detection mode after 5 seconds of idle time. The device will automatically analyze the gas environment and display the result on the screen.

  • Normal gas concentration
    If the gas concentration is below the low alarm value, the detection result will be displayed on the screen.

  • Abnormal gas concentration
    If the gas concentration is above the alarm value, the LED indicators and the backlight will light on, the device will vibrate and emit a beeping sound, and the current detection value will be displayed on the screen.

Gas type Detection range Optional range Low alarm High alarm Resolution
Oxygen 0–30% vol. 0–30% vol. 19.5 23.5 0.1% vol.
Methane 0–4% CH4 0–4% CH4 1.00 2.50 0.01% CH4
Carbon monoxide 0–1000ppm 0–2000/5000ppm 50 200 1ppm
Hydroge sulfide 0–100ppm 0–50/200/1000ppm 10 20 1/0.1ppm
Combustible gas 0–100% LEL 0–100% LEL 20 50 1% LEL
Ammonia 0–100ppm 0–50/500/1000ppm 20 50 1/0.1ppm
Hydrogene 0–1000ppm 0–40000ppm 200 500 1/0.1ppm
Chlorine gas 0–20ppm 0–100/150ppm 5 10 1/0.1ppm
Hydrogene chloride 0–20ppm 0–20/150ppm 5 10 1/0.1ppm
Sulfur dioxide 0–20ppm 0–50/100ppm 5 10 1/0.1ppm
Nitric oxide 0–250ppm 0–500/1000ppm 20 125 1/0.1ppm
Nitrogene dioxide 0–20ppm 0–50ppm 5 10 1/0.1ppm
Carbon dioxide 0–5000ppm 0–5%/10% vol. (infrared) 1000/0.2 2000/0.5

1ppm/0.1% vol.
Hydrogen phosphide| 0–20ppm| 0–20ppm| 5| 10| 1ppm
Hydrogen cyanide| 0–20ppm| 0–20ppm| 10| 25| 1ppm
Epoxy acetylene| 0–100ppm| 0–100ppm| 20| 50| 1ppm
Epoxy ethane| 0–100ppm| 0–100ppm| 20| 50| 1ppm
---|---|---|---|---|---
Ozone| 0–100ppm| 0–20/100ppm| 20| 50| 0.1ppm
Methanal| 0–40ppm| 0–50/100ppm| 8| 20| 1/0.1ppm
Benzene| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Methyl benzene| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Dim| ethyl benzene| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Volatile organic compounds (VOC)| 0–1000ppm| 0–1000ppm| 200| 500| 1ppm
Chlorethylene| 0–250ppm| 0–250ppm| 50| 125| 1ppm
Methyl alcohol| 0–30ppm| 0–30ppm| 6| 15| 1ppm
Isobutene| 0–90ppm| 0–90ppm| 18| 45| 1ppm
Alcohol| 0–80ppm| 0–80ppm| 16| 40| 1ppm

The display error for combustible gases is ±5%, for carbon monoxide is ±10%, for hydrogen sulfide is ±5%.

History record
The device can save the records of gas concentration alarms. You can select, view, or clear the records.

Specifications

Combustible gases to be detected| EX*| H2S (hydrogen sulfide)| CO (carbon monoxide)| O2 (oxygen)
---|---|---|---|---
Detection range| 0–100% LEL**| 0–100ppm| 0–1000ppm| 0–30% vol.
Response time| < 45s
Low alarm| 20% LEL| 10ppm| 50ppm| 19.5% vol.
High alarm| 50% LEL| 20ppm| 200ppm| 23.5% vol.
Explosion protection| Ex Ib IIB T3 Gb
Dimensions| 130x45x65mm
Weight| 200g
Operating temperature range| –20…+50°C (operating), –10…+55°C (storage) / –4… +122°F (operating), –14…+131°F (storage)
Power supply| rechargeable Li-ion battery, 3.7V, 2000mA·h; 24V, 1A adapter for charging

    • EX – explosive gases (hydrogen, carbon monoxide, methane, ethane, propane, butane, ethylene, propylene, butene, acetylene, propyne, butyne, hydrogen sulfide, phosphine, etc.)
  • LEL** – lower explosive limit

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

  • The device is designed to measure the concentration of gas in the air. If you measure high density gas, you might damage the device. Do not use or store the device in the corrosive atmospheres. Store the device in a dry cool place. Do not expose the device to shock, continuous vibrations, or extreme high or low temperatures. Do not try to disassemble the device on your own for any reason. For calibration, repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from sudden impact and excessive mechanical force. Only use accessories and spare parts for this device that comply with the technical specifications.
  • Always use only the recommended cleaning wipes and cleaning tools. Do not use any ethanol- or acetone-based fluids. Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.

Battery safety instructions

The device is equipped with a built-in rechargeable lithium-ion battery. This avoids frequent battery replacement. Always switch the device off when not in use. If the battery charge is low, please recharge the device in time to ensure that the measurements are accurate. Do not overheat the battery. Do not discharge the battery completely. Only use the original charger.

Levenhuk International Warranty

  • Levenhuk products, except for their accessories, carry a 5-year warranty against defects in materials and workmanship. All Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located if all the warranty conditions are met.
  • For further details, please visit: levenhuk.com/warranty
  • If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals