RCPORT-TD400 Series
Wireless Serial Adaptor
RS232/USB/RS422/RS485
Specifications
Model | RCPORT-TD400 | RCPORT-TD410 | RCPORT-TD420 | RCPORT-TD450 |
---|---|---|---|---|
Network Connectivity | Bluetooth Low Energy 5.2 | |||
Serial Ports | RS232 | Virtual Serial | RS 422/485 | |
Connector | D-SUB9 (F) | USB-A | D-SUB9 (M) | |
Transmission Distance | 1,000ft with defualt antenna | |||
Input Voltage | DC 5 – 24V | DC 5V | DC 5 – 24V | |
Battery | – | Built-in | – | |
Operating Temperature | -20 – 85°C | -20 – 60°C | -20 | – 85°C |
Operating Humidity | 0 – 85% |
Dimmensions (mm)
without ANT
| 80.3 x 343 x 17.4| 80.3 x 343 x 23.7| 70 x 21.6 x 14.3| 80.3 x 34.3 x 17.4
Max. Connect Devices| Up to 7
Operating Role| Master/Slave
Antenna| +1 dBi
Baud Rate| 9,600 –115,200 bps
Certifications| SIG, CE, FCC, JAPAN MIC, KC
About Dials
-
Baud Rate Dial
Select baud rate or Set mode. -
Device Selection Dial Master only
Select one of the Slave devices to communicate. -
Operation Switch
-
Serial Interface Dial
Slect RS422, RS485 or Set mode. -
Device Selection Dial Master only
Select one of the Slave devices to communicate. -
Operation Switch
Auto Pairing
Case 01
Easily connect 1:1 without configuration software. Keep them as close together
as possible.
Node Switching
Case 02
Place the Master’s device selection dail from 1 to 7 for communication with
Slave devices registered to the number.
(Please refer to video guide bottom for the details.)
Multi Connection
Case 03
Place the Master’s device selection dial to M for Simultaneous communication
with all registered Slave devices.
(Please refer to video guide right for the details.)
For more information
Download Online Cataloguehttps://disk.chipsen.com/en.chipsen/RCPORT-
TD400series_catalogue(ENG).pdf
Watch Veido Guide
https://www.youtube.com/playlist?list=PLirM7-CB5JRISTDYAFy8CN0mFRaOL6hUX
The configuration software and relateed documents are available on the
download page at the website below.
https://en.chipsen.com
global@chipsen.com
https://en.chipsen.com
501 M-Cluster, 17 Deogan-ro 104beon-gil, Gwangmyeong-si, Gyeonggi-do, Republic
of Korea
General Warranty Policy
These products are warranted for an year from the date of purchase, and the compensation policy is as follows.
-
Devices covered by warranty: RCPORT-TD400/410/420/450
-
Warranty period: 1 year from the date of purchase (15 months from the date of manufacture if the purchase date is not confirmed)
-
Free warranty
• In case of a defects within the warranty period -
Paid warranty
• If products are out of warranty
• When used in conditions that exceed the stated specifications (temperature, humidity, power, etc.)
• In case of defects caused by arbitrary modification or repair
• In case of a failure due to a natural disaster (fire, water damage, lightning strike, etc)
• Other defects caused by consumer negligence
CAUTION: These devices may cause radio interference during operation.