levenhuk ERMENRICH SEEK DS10 Digital Sound Level Meter User Manual
- June 1, 2024
- levenhuk
Table of Contents
- User Manual
- Ermenrich Seek DS10 Digital Sound Level Meter
- Display information
- Operation
- Automatic shutdown mode
- MAX/MIN measurement
- FAST/SLOW time weighting
- Low battery indication
- Specifications
- Care and maintenance
- Battery safety instructions
- Ermenrich Warranty
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
levenhuk ERMENRICH SEEK DS10 Digital Sound Level Meter
User Manual
- Windscreen
- Microphone
- MAX/MIN button
- FAST/SLOW button
- Power button
- LCD
- Battery compartment cover
Ermenrich Seek DS10 Digital Sound Level Meter
The kit includes : digital sound level meter, user manual, and warranty card.
Getting started
- Open the battery compartment cover and insert 2 AAA batteries. Close the cover.
- Press the Power button to turn the device on or off.
Display information
- Automatic shutdown mode
- Automatic range
- Maximum value mode
- Minimum value mode
- Low battery indicator
- A-weighted value
- Measurement unit (decibels)
- Measurement value
- Slow time weighting
- Fast time weighting
Operation
The sound level meter shows the A-weighted noise level data (A icon [6] on the display). The range is selected automatically (AUTO icon [2]) depending on the current noise level.
During the measurement, keep the microphone facing toward the noise source. Wind blowing across the microphone may distort the measurement results. Cover the microphone with the windscreen (included) when in operation.
Automatic shutdown mode
When the device is turned on, the automatic shutdown icon [1] is displayed.
The automatic shutdown function is turned on by default. If there is no
operation within 10 minutes, the meter will automatically shut down. To cancel
the automatic shutdown function, press and hold the MAX/MIN button, and then
press the Power button to turn the device on.
Restart the instrument after shutdown to restore the automatic shutdown
function.
MAX/MIN measurement
Pressing the MAX/MIN button once puts the device in MAX mode [3]. In MAX mode,
the device shows the maximum data value during the current measurement cycle.
Pressing the MAX/MIN button twice puts the device in MIN mode [4]. In MIN
mode, the device shows the minimum data value during the current measurement
cycle.
To exit the MAX/MIN measurement modes, press the MAX/MIN button and hold it
for 2s.
FAST/SLOW time weighting
Press the FAST/SLOW button to choose between the fast (125ms) and slow (1s)
time weighting modes. The display will show either the FAST [10] or SLOW [9]
icon, depending on which mode is currently selected.
Select fast time weighting mode to capture noise peaks and quick-emerging
noises. This mode is suitable for most applications.
Select slow time weighting mode to monitor sound sources with consistent noise
levels and average out the quickly changing noises.
Low battery indication
When the battery voltage is low, the device shows the low battery icon [5]. It is recommended to replace the depleted battery as soon as possible to avoid inaccurate readings.
! To avoid damaging the device, do not open the battery compartment cover when the device is turned on.
Specifications
Sound pressure, range | 30–130dBA |
---|---|
Sound pressure, accuracy | ±1.5dB (94dB at 1kHz), ±5dB (94dB at 8kHz) |
Sound pressure, frequency response | 30Hz… 8kHz |
Sound pressure, time weight | FAST 125ms, SLOW 1s |
Operating temperature range | 0… +50°C (+32… +122°F) |
Storage temperature range | 0… +50°C (+32… +122°F) |
Power supply | 2pcs AAA 1.5V alkaline batteries |
Safety rating | EN61326-1 |
The manufacturer reserves the right to make changes to the product range and specifications without prior notice.
Care and maintenance
Take the necessary precautions when using the device with children or others
who have not read or who do not fully understand these instructions. Do not
try to disassemble the device on your own for any reason. Do not use the
device if it is damaged or does not operate properly. Replace the battery as
soon as the low battery indicator lights up. Do not use solvent to clean the
device. Store the device in the place with appropriate temperature (see
“Specifications”). Protect the device from sudden impact and excessive
mechanical force.
Never attempt to operate a damaged device or a device with damaged electrical
parts! Only use accessories and spare parts for this device that comply with
the technical specifications. If a part of the device or battery is swallowed,
seek medical attention immediately. Keep away from children.
Battery safety instructions
Always purchase the correct size and grade of battery most suitable for the
intended use. Always replace the whole set of batteries at one time; taking
care not to mix old and new ones, or batteries of different types. Clean the
battery contacts and also those of the device prior to battery installation.
Make sure the batteries are installed correctly with regard to polarity (+ and
–). Remove batteries from equipment that is not to be used for an extended
period of time. Remove used batteries promptly. Never short-circuit batteries
as this may lead to high temperatures, leakage, or explosion. Never heat
batteries in order to revive them. Do not disassemble batteries.
Remember to switch off device after use. Keep batteries out of the reach of
children, to avoid risk of ingestion, suffocation, or poisoning. Utilize used
batteries as prescribed by your country’s laws.
Ermenrich Warranty
Ermenrich products, except for their accessories, carry a 5-year warranty
against defects in materials and workmanship. All Ermenrich accessories are
warranted to be free of defects in materials and workmanship for six months
from the purchase date. The warranty entitles you to the free repair or
replacement of the Ermenrich product in any country where a Levenhuk office is
located if all the warranty conditions are met.
For further details, please visit:
levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product,
contact the local Levenhuk branch.
Customer Support
Levenhuk USA 928 E 124th Ave. Ste D, Tampa, FL 33612, USA, +1 813 468-3001,
contact_us@levenhuk.com
Levenhuk®, Ermenrich® are registered trademarks of Levenhuk Optics s.r.o.
(Europe).
2006–2024 Levenhuk, Inc. All rights reserved.
ermenrich.com 20240419
References
- Доживотна гаранция на Levenhuk – Официален уебсайт на Levenhuk в България
- Doživotní záruka společnosti Levenhuk – Oficiální webové stránky Levenhuk pro Českou republiku
- Levenhuk Lebenslange Garantie – Die offizielle Website von Levenhuk in Deutschland
- Levenhuk’s official website in Europe
- Garantía internacional de por vida Levenhuk – Web oficial de Levenhuk en España
- Levenhuk Lifetime Warranty – Levenhuk’s official website in USA
- A Levenhuk élettartamra szóló szavatossága – A Levenhuk hivatalos magyarországi weboldala
- Levenhuk Limited Warranty – Levenhuk’s official website in USA
- Поддержка - Гарантийное обслуживание Левенгук - Levenhuk Russia
- Gwarancja bezterminowa Levenhuk – Oficjalna witryna internetowa Levenhuk w Polsce
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>