MW30 Moisture Detector - FIG 4

User Manuallevenhuk Ermenrich Wett MW30 Moisture Detector -
ICON

levenhuk Emmerich Watt MW30 Moisture Detector

levenhuk Ermenrich Wett MW30 Moisture Detector - FIG

  1. Protective cap
  2. Pins
  3. Low moisture indication
  4. Medium moisture indication
  5. High moisture indication
  6. Building material moisture scale
  7. Wood moisture scale
  8. Temperature
  9. Current moisture value
  10. Low battery indicator
  11. HOLD icon
  12. WOOD icon
  13. BLDG icon
  14. Calibration scale
  15. HOLD button
  16. °C/°F button
  17. Right arrow button
  18. MODE / ON/OFF button
  19. Battery compartment

Please carefully read the safety instructions and the user manual before using this product. Keep away from children. Use the device only as specified in the user manual.

Getting started

  • Open the battery compartment cover and insert 2 AAA batteries. Close the cover.
  • Remove the protective cap as shown below (Fig. 1).

levenhuk Ermenrich Wett MW30 Moisture Detector - FIG 2

  • Press (18) to turn the device on. Press (18) and hold it for 3 seconds to turn the device off.

Calibration

To check if the device works correctly, take a test measurement.
Turn the device on. Select the wood measuring mode and wood density grade A. Insert the pins into the measurement holes (Fig. 2). The measured value will be shown on the screen. If the value is between 16.6% and 20.6%, the device works correctly.

levenhuk Ermenrich Wett MW30 Moisture Detector - FIG 3

Mode setting
Turn the device on and press (18) to set the measuring mode.
The setting order: wood -> building material

Wood density grade
For Wood calibration tables, see Appendix A (in English). In wood measuring mode, press (17) to set the wood density grade. Density is classified into eight grades (A–H).

Temperature
Press (16) to switch between °C and °F.

Using
Carefully press the test pins into the material whose moisture level you wish to measure. The level will be displayed as a percentage.
To hold the current measurement on the screen, press (15). The HOLD icon will be displayed. Press (16)/(17) to turn the hold function off and return to measurements.

Moisture indication

| Green light (low moisture)| Yellow light (medium moisture)| Red light (high moisture)
---|---|---|---
Wood| < 12%| 12… 15.9%| 16… 60%
Building material| < 17%| 17… 19.9%| 20… 33%

Specifications

Type contact
Resolution 0.10%
Measurement accuracy ±2%
Measuring range Wood: 6–60%

Building material: 1.5–33%
Operating temperature range| 0… +50°C (operating), –10…+50°C (storage) / 32…122°F (operating), 14…122°F (storage)
Operating humidity range| 0–90%
Auto-off| 3 min
Power supply| 2pcs AAA batteries

The manufacturer reserves the right to make changes to the product range and specifications without prior notice.

Care and maintenance

Use the device only as specified in the user manual. Keep away from children. Do not try to disassemble the device on your own for any reason. For repairs and cleaning of any kind, please contact your local specialized service center. Protect the device from  sudden impact and excessive mechanical force. Do not use the product in explosive environment, close to flammable materials. Store the device in a dry cool place. Only use accessories and spare parts for this device that comply with the technical specifications.  Never attempt to operate a damaged device or a device with damaged electrical parts! If a part of the device or battery is swallowed, seek medical attention immediately.

Battery safety instructions

Always purchase the correct size and grade of battery most suitable for the intended use. Always replace the whole set of batteries at one time; taking care not to mix old and new ones, or batteries of different types. Clean the battery contacts and also those of the  device prior to battery installation. Make sure the batteries are installed correctly with regard to polarity (+ and –). Remove batteries from equipment that is not to be used for an extended period of time. Remove used batteries promptly. Never short-circuit  batteries as this may lead to high temperatures, leakage, or explosion. Never heat batteries in order to revive them. Do not disassemble batteries. Remember to switch off devices after use. Keep batteries out of the reach of children, to avoid risk of ingestion,  suffocation, or poisoning. Utilize used batteries as prescribed by your country’s laws.

Levenhuk International Lifetime Warranty

All Levenhuk telescopes, microscopes, binoculars, and other optical products, except for their accessories, carry a lifetime warranty against defects in materials and workmanship. A lifetime warranty is a guarantee on the lifetime of the product on the market. All  Levenhuk accessories are warranted to be free of defects in materials and workmanship for six months from the purchase date. The warranty entitles you to the free repair or replacement of the Levenhuk product in any country where a Levenhuk office is located  if all the warranty conditions are met.
For further details, please visit: www.levenhuk.com/warranty
If warranty problems arise, or if you need assistance in using your product, contact the local Levenhuk branch.

levenhuk LOGOLevenhuk Inc. (USA): 928 E 124th Ave. Ste D, Tampa, FL 33612,
USA, +1-813-468-3001, contact_us@levenhuk.com
Levenhuk Optics servo. (Europe): V Chotejně 700/7, 102 00 Prague 102,
Czech Republic, +420 737-004-919, sales-info@levenhuk.cz
Levenhuk®, Emmerich® are registered trademarks of Levenhuk, Inc.
© 2006–2023 Levenhuk, Inc. All rights reserved.
www.levenhuk.com
20230309

Documents / Resources

| levenhuk Ermenrich Wett MW30 Moisture Detector [pdf] User Manual
Ermenrich Wett MW30 Moisture Detector, Ermenrich Wett MW30, Moisture Detector, Detector, Moisture
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals