mitzi H886803 Aston 8 Tall Wall Sconce Instruction Manual

June 2, 2024
mitzi

mitzi H886803 Aston 8 Tall Wall Sconce

mitzi-H886803-Aston-8-Tall-Wall-Sconce-PRO

Product Information

Specifications:

  • Brand: Hudson Valley Lighting
  • Model: Aston H886803
  • Maximum Wattage: 8 watts (Type G16.5 lamp)

Product Usage Instructions

Fixture Installation:

  1. Feed the wire through the STEM KIT (H) and twist tightly onto the FIXTURE ASSEMBLY (I). Add stems as needed for desired hanging height.
  2. Slide CANOPY (F) onto the STEM KIT (H), and thread CONNECTOR (G) onto the top end of the STEM KIT (H).
  3. Pull wire out from the junction box, and install MOUNTING PLATE (A) using MOUNTING SCREWS (B) on a standard round or octagon junction box securely mounted to the building structure.
  4. Trim excess wire to a minimum of 6 inches beyond the STEM, strip each wire 5/8 inch.
  5. Attach Ground wire (Green) to the ground inside the outlet box or GROUND SCREW (C) on MOUNTING PLATE (A). Never connect ground wire to hot wire.
  6. Connect white fixture lead to the neutral wire in the outlet box using an approved fastener (WIRE NUT) (D). Seal connection with electrical tape to prevent short circuits.
  7. Connect black fixture leads to the hot wire in the outlet box. Secure connections properly. Never reverse hot and neutral wires.
  8. Push wires back into the junction box, lift CANOPY (F) to the ceiling, and secure with CAP NUTS (E).
  9. Place GLASS (L) onto FIXTURE ASSEMBLY (I) and secure with RING (K).
  10. Screw BULB (J) into the SOCKET of the fixture. Do not exceed the maximum recommended wattage.
  11. Restore power at the breaker or fuse box.

FAQ:

  • Q: Can I use a bulb exceeding 8 watts with this fixture?
    A: No, this fixture is rated for a maximum of 8 watts with a Type G16.5 lamp. Exceeding the recommended wattage can damage the fixture.

  • Q: How should I secure the canopy to the ceiling?
    A: Lift up the canopy to the ceiling after pushing the wires back into the junction box, then secure it with the cap nuts provided.

  • Q: What should I do if I encounter exposed wires during installation?
    A: Ensure there are no exposed wires or strands that could cause a dangerous short circuit. Properly insulate any exposed areas with electrical tape.

WARNING/CAUTION

  • DISCONNECT POWER BEFORE RE-LAMPING OR WIRING THE FIXTURE. READ ALL INSTRUCTIONS COMPLETELY BEFORE STARTING INSTALLATION.
  • TO AVOID THE RISK OF FIRE OR SHOCK, FIXTURE MUST BE INSTALLED IN COMPLIANCE WITH ALL APPLICABLE NATIONAL AND LOCAL ELECTRICAL/BUILDING CODES. THE INSTALLATION AND MAINTENANCE\ OF THIS UNIT SHOULD BE COMPLETED BY A LICENSED ELECTRICIAN OR CERTIFIED FACTORY TRAINED TECHNICIAN.
  • CALIFORNIA PROP 65: THIS LIGHTING FIXTURE CONTAINS CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS, AND/OR OTHER REPRODUCTIVE HARM. WASH HANDS AFTER USE.
  • UNPACK FIXTURE, PARTS AND PARTS BAG(S) BEFORE DISCARDING THE CARTON. MAKE CERTAIN THAT ALL PARTS ARE FOUND. INSPECT THE FIXTURE PRIOR TO INSTALLATION FOR ANY DAMAGE. HVLG DOES NOT PAY OR REIMBURSE ELECTRICIAN FEES. FIXTURE MAY NOT BE RETURNED ONCE IT HAS BEEN INSTALLED. SEE WARRANTY FOR EXCEPTIONS.
  • PLEASE CLEAN WITH A SOFT, DRY CLOTH ONLY! DO NOT USE CLEANSERS.

PART LIST

mitzi-H886803-Aston-8-Tall-Wall-Sconce-1 mitzi-H886803-Aston-8-Tall-Wall-Sconce-2

FIXTURE INSTALLATION

  1. Feed the wire through the STEM KIT (H) and twist tightly onto the FIXTURE ASSEMBLY (I). Keep adding additional stems until you desired hanging height is met.
  2. Slide in CANOPY (F) onto the STEM KIT (H), and thread the CONNECTOR (G) onto the top end of the STEM KIT (H).
  3. Pull the wire out from the junction box, and install the MOUNTING PLATE (A) onto the junction box using the MOUNTING SCREWS (B). This fixture is designed to be mounted on standard round or octagon junction box. The junction box must be securely mounted to the structure of the building.
  4. Trim off the excess wire to a minimum 6″ beyond the STEM and strip each wire 58″.
  5. Attach the Ground wire (Green) to the ground inside the outlet box (Generally green or bar copper wire) or the GROUND SCREW (C) on the MOUNTING PLATE (A). NEVER CONNECT GROUND WIRETO “HOT” WIREĞ FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH.
  6. Connect the white fixture lead to the neutral (Generally white) wire in the outlet box. Fasten the wire together with an approved fastener ( WIRE NUT) (D). Starting 1″ below the fastener, tightly wrap the connection with electrical tape so that the connection seals the end of the fastener. MAKE SURE THERE ARE NO EXPOSED WIRE OF STRANDS THAT COULD CAUSE A DANGEROUS SHORT CIRCUIT.
  7. Connect the black fixture leads to the hot (Generally black) wire in the outlet box. Fasten the joined wires same as previous step. NEVER REVERSE HOT AND NEUTRAL WIRES. FAILURE TO FOLLOW THIS COULD RESULT IN SERIOUS INJURY OR DEATH.
  8. Push the wires back into the junction box. Lift up the CANOPY (F) up to the ceiling, and secure withthe CAP NUTS (E).
  9. Place GLASS (L) onto the FIXTURE ASSEMBLY (I) and secure it with the RING (K).
  10. Screw the BULB (J) into the SOCKET of the fixture. THIS FIXTURE IS RATED FOR MAX 8-WATT TYPEG 16.5 LAMP. DO NOT EXCEED THE RECOMMENDED WATTAGE.
  11. Restore power to the outlet at the breaker or fuse box.

www.hvlgroup.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>