SAFETY INFORMATION
This series of meter fulfill IEC1010 International Electrotechnical Commission
Please read the Safety Information before use
Read the technical specifications carefully Only the model with multimeter
function is allowed to measure DCV ACV and Current with 36V or above
Never measure 36V or above except PoE if the model do not have multimeter
functions These voltages pose a shock hazard
- For measuring voltage never input more than 1000V DC or 400V AC RMS For measuring current never input more than 10A
- It is save for 36V or below To avoid electric shock check the testleads connection and insulation before measure 36V DC or above and 25V DC or above
- Remove the testleads from the testing point before switching functions and ranges
- The meter already has full protections But for safety sake please select the correct function and range
- Safety symbols Hazardous voltage please refer user manual Earth Low battery voltage
WARNING
- Do not use the equipment if it looks damaged and or abnormal The protection in the meter may be damaged if it looks damaged and or abnormal.
- Do not input over the range Otherwise user may be injury and the meter may be damaged.
- Do not use the meter just before during or just after an electrical storm.
- Remove the batteries if the meter planned to be stored for long period If the batteries are not removed battery leakage can damage the meter.
- The meter is not allowed to search check energized cables Contact with energized cable may hurt the users and cause the meter damaged.
- Only testleads are allowed to connect to the meter when using the multimeter User may be hurt and or meter will be damaged if other ports are connected to energized cable except PoE equipment.
- Please check the battery if low battery indicator on LCD of main body turns on and or the red LED on the receiver is flash.
- Do not open the case If needed ask professional to repair the meter.
INTRODUCTION
This meter combines with the cable tracing cable length measuring and
multimeter functions. The advantage of this meter is the long tracing
distance, clear sound signals, rapid and precise cable length measurement, and
accurate multimeter.
The meter is good tools for laboratories, factories, radio lover, network
installer, and technician, It can real time measuring network cable length,
short circuit and circuit break.
The cable tracing function can quickly and efficiently find out the target
cable in large number of cables. This function can be used in telephone
systems, computer networks, BNC cables and other metallic network cables.
Our digital tracing apply the newest digital noise free technology. It give a
good experience to users.
The meter is essential equipment for computer networking, telecom cabling, BNC
cabling and other metallic cabling projects.
Working Principal
Cable length measurement is performed by sending a signal to one of the wire
in the cable. By receiving and calculating the reflected pulse to get the
cable length.
By sending a signal from the MAIN port to the target cable, an analogue signal
field will be generated. The receiver will identify the signal field and find
out the target cable.
- Network cable length measurement max 500m.
- Multimeter functions.
- Cable tracing.
- Nice and professional outlook.
- Many cable testing method and PoE Voltage measurement.
- Flashlight.
- Auto power off.
- Sensitivity Sound level adjustment.
- Using rechargeable lithium battery for protecting the environment.
PRODUCT INCLUDE
- Transmissor
- Receiver
- User Manual
- 9V Battery
- 3 7 Lithium Battery
- Alligator Clip
- RJ45 Cable
- USB Transformer
- Multimeter Accessories (Testleads and k type temperature probe)
EQUIPMENT OPERATION
Tracing Cables (SCAN) | Find out the target cable in numerous cables, |
---|---|
Cable Pairing Check (TEST) | Test open circuit, short circuit and cable mapping |
V (VOLT) | Check the polarity and voltage of battery/phone line |
Continuity Test (OHM) | Check open circuit or short circuit of phone line(phone |
line should not be connected to any power source)
ID Pairing| Able to check Network Switches and Cables by connecting one end to
the Remote ID unit
PoE Test| Checking cable mapping, polarity and voltage of PoE Network Switches
Flashlight| White flashlight
Sensitivity Adjustable| Able to adjust the sound level
Length Measurement| Able to measure cable length, short circuit and circuit
break
Cable Tracing Signal Changable| Able to set the frequency for using on tracing
Multimeter| Have DCV, ACV, Continuity, Diode, Voltage, Temperature, NVC,
Resistance, DCA and DCV
PRODUCT DESCRIPTION
WARNING
The product will be damaged if Length Measurement Port is connected to PoE or
any energized devices.
PRODUCT INFORMATION
-
MAIN network cable Input jack MAIN : Connect network cable, phone line and the alligator clip cable to this jack for checking pairs, tracing cable, PoE Polarity checking, battery voltage measurement or continuity; LENGTH : Connect to this jack for measuring cable length;
-
Result Display Displaying the product status, testing result, connection indication.., battery power.
-
Push Button
3.1 powER/moDE button : Pressing 2 seconds to switch on the product; Press to select functions (length – cable pairing – tracing cable – V -continuity – network switch cable pairing – network switch indicator flashing — Remote ID tracing – PoE Voltage – NCV – Length):
3.2 button : Pressing tracing function, switch between analogue and digital signal. During Cable Length measurement, press to change the pair. During pairing function, perform normal pairing function. Keep pressing switch on / off the display backlight;
3.3 button : Press to switch between analogue and digital signal. During cable length measurement, select the cable type. During cable pairing check, select the high speed pair checking function. Keep pressing to switch on / off the display backlight;
3.4 SCAN button : press to select the cable tracing function (Only apply to the model without multimeter function):
3.5 DMM button (only for model with multimeter) : press to select the multimeter function. In multimter function, press to select ACV- DCV -Continuity – Diode – Temperature – NVC – Resistance – ACA – DCA) -
Tracing Sensor : Move this part towards the target cable (network cable, phone line, BNC cable or other metallic cable). Listen the sound level to position the target cable.
-
Flashlight : Location of flashlight. It can be switch on/off by a separate switch;
-
Sound / Sensitivity adjusting wheel : For analogue mode, it used to adjust the sound level. For digital mode, it used to adjust the frequency.
-
Flashlight Switch : Switch on/off the flashlight
-
SCAN Button : Switch on/off the cable tracing function. Pressing 2 seconds to switch on the product, press to switch between analogue tracing, digital tracing, digital vibrating mode. Pressing 2 seconds again to switch off.
-
Indicators : at the cable pairing function, LED on indicating the relative cable is in good condition.
-
RJ45 Cable Jack
DIGITAL CABLE TRACING
Product is a noise free digital wire tracker. The product apply the advance
digital technology to achieve precious digital noise free cable tracing.
Following is the comparison of digital wire tracker and analogue wire
tracker.:
Operation
Operation of the main body is the same. The receiver operation is different.
Press SCAN button for 2 seconds to switch on. Press to switch between digital
cable tracing, digital tracing with vibration (if the model have), analogue
cable tracing. Press 2 for 2 seconds to switch off. The product will
automatically switch off if no operations for 10 minutes.
After selecting the function of the Receiver by pressing the SCAN button, it
is no need to press button.
Press SCAN button on the Main Body to select the searching function. Press Hz
button to switch to the digital search (L2) mode. In digital search mode, it
is not allow to change the searching frequency.
To speed up the searching process, it is recommended to maximize the
sensitivity by turning the Sensitivity adjusting wheel. When the target cable
is closed, adjust the sensitivity to identify the target cable. To confirm the
target cable is the correct cable to be searched, it is recommended to plug
the target cable in the RJ45 jack on the Receiver. If all the LED on the
Receiver are switch on, the cable connected is the target cable.
Digital Search ( Blue LED indicator) The latest digital searching
technology is applied. The Main Body sends out digital signal. By receiving
the digital signal passing through the target cable, the Receiver will have
sound response (blue indicator switch on) or vibrating (blue indicator
flashing).
Analogue Search ( Red LED indicator) To speed up the searching process,
it is recommended to maximize the sensitivity by turning the Sensitivity
adjusting wheel. When the target cable is closed, adjust the sensitivity to
identify the target cable.
The product is ready for measuring cable length after it is switching on. This
function can apply to different metallic cables (with at least 2m) including
network cables, phone lines and BNC cable. To measure length, plug the cable
to LENGTH jack. Free the other end of the cable. It is not allowed to connect
to any other equipment. The product may be damaged if the other end of the
cable is connected to any powered equipment. After measuring the length, the
product will display the cable conditions. The status of each cable (in the
sequence of 1,2,3,4,5,6,7,8) will be displayed. Users can determine the cable
is in good conditions or not together with the cable length. Press — button to
switch to measure the length of each pair of cables (ie. pair of 1 and 2, 3
and 6, 4 and 5. 7 and 8). Press button to select the cable type (include 8P8C
cables, 4P4C cables, phone lines and BNC cables.
WARNING
LENGTH jack is designed to measure cable length. The product may be
damaged if it is connected to PoE or any other energized equipment.
Operation
Press Power button to switch on the product. Then the product is ready for
measuring cable length. At the bottom of display, the 8P8C network cable, 4P4C
network cable, phone lines and BNC cable.
LENGTH CALIBRATION LENGTH & TEMP()
Length Calibration
Due to the conductivity difference of cable made by different materials, the
measuring results may not be accurate. To solve the issues, this product allow
users to calibrate itself.
Calibration Method
- After switching on the product, connect a cable with known length to the LENGTH jack on the Main Body. At the cable length measuring mode, pressing — and buttons together for 3 seconds. The product will be ready at the user calibrating mode. The measuring result will be flashing. User can press — or buttons to adjust the measuring result until the displaying value is the same as the actual cable length. Then press and MODE button together to save the calibrating result and leave the user calibrating mode. Press any other buttons will leave the user calibrating mode without saving the result.
- After switching on the product, pressing — and MODE button together to reset the product to the factory setting.
- The known length cable for using on calibration should have at least 5M long.
Temperature Calibration
The measuring result may be affected by the temperature difference between the
environment and product inside. To solve the issue, the product have
temperature calibration mode. Following is the calibrating method.
- After switching on the product, select the measuring mode, pressing and buttons together for 3 seconds. The product will be ready at the temperature calibrating mode. The measuring result will be flashing. User can press — or buttons to adjust the measuring result until the displaying value is the same as the actual cable length. Then press and MODE button together to save the calibrating result and leave the user calibrating mode. Press any other buttons will leave the user calibrating mode without saving the result.
- After switching on the product, pressing — and MODE button together to reset the product to the factory setting.
- During temperature calibrating, please refer to mercury thermometer with resolution at 0.1°C.
CABLE MAPPING TEST
By using the cable mapping function, users can check the open circuit and
cables’ physical connection of the following cables.
1.UTP computer network cables fulfill IEEE 10Base-T, EIA/TIA 568A standard;
2.2 core, 4 core phone lines and other metallic network cables. Plug one end
of the cable being tested to the MAIN jack on the Main Body. Press MODE button
to switch to the cable mapping mode. Press the other end of the cable to the
RJ45 jack on the Receiver. If the indicator on the receiver match with the
indicator number showing on th Main Body, the cable being tested is in good
condition. Please refer to the following figures for details.
• ID
Not a standard accessory
Operation
Press MODE button to switch between Cable Mapping (TEST), switch mapping ,
checking LED indicators of jacks on switches, and test with remote ID unit.
Plug one end of the cable being test to the MAIN jack on the Main Body. Plug
the other end to the related jack.
For testing cable, plug the other end of the cable in the MAIN jack on the
Receiver. The Main Body will display the conductor conditions one by one.
Press — to select the fast mode. Press to select the normal mode. For switch
mapping, connect the other end of the cable to the switch. The Main Body will
display the conductor conditions one by one.
For checking the Switch indicators flashing ( ), connect the other end of the
cable to the switch being testing. The indicator of the jack on the switch
which is connecting to the Main Body will flash once per second. For testing
with the Remote ID Unit, connect the other end of the cable to the Remote ID
Unit. The Main Body will show the number of the Remote ID that is connected.
MEASURING VOLTAGE (VOLTAGE)
The product can help to identify some issues on a circuit. The issues include
the present of voltage, polarity of voltage. There is no need to use the
receiver for this function. Plug the alligator clip cable comes with the
product in the MAIN jack on the Main Body. Clip the alligator clips on the
objective circuit. If voltage is present on the phone line, conductor 3 and 4
will have a long connection lines. The positive conductor will also flash. If
there is no voltage, short connection lines of conductor 3 and 4 will be
displayed. Alternatively, user can plug the phone line in the MAIN jack to
check if the line is installed with RJ11 plug.
Remarks : It is not allowed to measure AC Voltage and other High Voltage
Circuit. Otherwise, it may cause electric shock.
WARNING It is domogous to connecting PoE or other energized sources to
the LENGTH jack. It may cause electric shock.
Operation
After switching on the product, press MODE button until it is ready at Voltage
Testing Mode. Connect the target battery or other power sources by using the
alligator clip cables provided. The polarity will be displayed. After
switching on the product, press MODE button until POE and V is shown on the
display. The product is now ready at Voltage Testing mode. It will display the
voltage and polarity. The number of the positive conductor will be flash.
CABLE TRACING (SCAN)
This function can help users to identify the target cable from lots of cables.
Plug one end of the target cable (such as network cable, phone line and all
BNC cable which can be clip by the alligator clip provided) in the MAIN jack
on the Main Body. Switch on the Main Body. Select the cable tracing function.
For the model without multimeter functions, SCAN button is located at the
right side. Press to select the cable tracing function. Pressing the SCAN
button on the Receiver for 2 seconds, blue indicator (digital searching) or
red indicator (analogue searching) will switch on. Move the Receiver around
the uncertain cables (including network cable, patch panel of phone system,
connector, hub). Listen and compare the sound signal. When the Receiver is
closing to the target cable, the sound level will increase. The loudest sound
will be obtained if the Receiver is next to the target cable. For working in
noisy environment, press — button to change signal for easy identification.
The product have two analogue signals which indicated by 1 and 3 and one
digital signal which indicated by 2 on the display. It can directly plug in
the cable if it is installed with registered jack.
Operation
After switching on the product, press MODE button to select the cable tracing
function. Plug the testing cable in the MAIN/RJ45 jack or connect the testing
cable by the alligator clips provided. Press the SCAN button on the Receiver.
Blue indicator will switch on which indicate it is ready for digital tracing.
CONTINUITY TEST (CONTINUITY)
The function is to test the short circuit of a phone line which is not plug in
any networks. Ensure the phone line is not powered before testing. The display
will indicate open circuit.
For those cables with registered jack, directly plug the cable in the
MAIN/RJ45 to test. Otherwise, connect the testing cable by using the alligator
clips provided.
This function can also apply to test the continuity of other equipment.
The product will display the circuit is opened or not.
Operation
After switching on the product, press MODE button until applies. The product
now is ready for continuity test. Clip the alligator clips on the testing
object. If the resistance is smaller than 10, the display will indicate the
circuit is shorted and have sound indication.
TROUBLE SHOOTING
Main Body Symptoms : Display is not on or flashing after pressing the Power
button
Reasons : Battery gone
Solutions : Charging the Main Body or replace the battery (protected 3.7V
lithium battery) Receiver Symptoms: Press SCAN button but no sound is
generated during cable tracing Reasons : Battery gone or No battery or
Receiver is too far away from the target cable Solutions : Change battery or
enlarge the searching area
OPERATION MANUAL
Following instructions are only applied to the model with multimeter
functions.
1.1 Voltage Measuring
- Plug the black lead to the COM jack. Red lead in the VHz jack.
- Press DMM button. Select AC Voltage (ACV) or DC Voltage (DCV).
- Touch the probe on the testleads to the testing point. The product will display the voltage measured. For measuring the DC Voltage, the polarity of red lead will be displayed.
Cautions
a.lf OL is displayed, the measuring voltage is over ranged. Please stop
measurement.
b.lt is not allowed to measured voltage over 1000V DC or 400V AC.
c.Do not touch the Hi-voltage circuit, never connect network cable, live wire
or charging cable when measuring Hi-voltage.
1.2 Current Measuring
- Plug the black lead to the COM jack. Red lead in the 10A jack.
- Press DMM button. Select DC or AC Current.
- Touch the probe on the testleads to the testing point. The product will display the current measured. For measuring the DC Current, the polarity of red lead will be displayed.
Cautions
a.lf OL is displayed, the measuring current is over ranged. Please stop
measurement.
b.lt is not allowed to measured current over 10A (measuring time less than 10
seconds)
1.3 Resistance Measuring
- Plug the black lead to the COM jack. Red lead in the VHz jack.
- Press DMM button. Select the resistance function, touch the testleads across the testing object.
Cautions
a.lf OL is displayed, the measuring resistance is over ranged.
b.OL will also be displayed if the testing object is an open circuit.
c.Ensure the testing object is removed from energized circuit and/or fully
discharge before measurement.
d. Do not input voltage in the resistance range.
e. For high resistance measurement (> 1 M), It is normal for taking several
seconds to obtain a stable reading.
1.4 Temperature Measuring
Press DMM button. Select the temperature range. Plug the cold end (free end)
negative (black) end of the thermocouple sensor in COM jack. Plug the red end
at the VHz jack. Put the sensor part of the thermocouple in the testing
objects or the surface of it. The temperature will be displayed.
Cautions
a. Please use only k-type thermocouples. Otherwise, the reading may not be
accurate.
b. Never input voltage in the temperature range.
1.5 NCV Detection
Press DMM button, select NCV detection range. Move the sensor close to the
testing object. The voltage will be displayed on the analogue bargraph. When
voltage is detected, the buzzer will create beep sound.
1.6 Continuity Test
- Plug the black lead to the COM jack. Red lead in the VHz jack (Please be noted that the polarity of the red lead is “+” ).
- Press DMM button. Select the continuity function. Touch the testleads across the testing object. The buzzor will sound if the resistance between the 2 contact points is less than 50L1.
1.7 Diode Test
- Plug the black lead to the COM jack. Red lead in the VHz jack (Please be noted that the polarity of the red lead is “+” ).
- Press DMM button. Select the diode range. Connect the red lead to the positive side of the diode. Connect the black lead to the negative side.
1.8 Auto Power Off
The equipment will enter the sleep mode if there is no function or button
press for 20 minutes. In the sleep mode, press Power button will return to
normal.
2. 1 Testleads connection
The product have input jack indicators to remind users to plug-in the correct
jacks. Mis-plugging the leads may damage the product and/or hurt the users.
Please ensure the connection is correct before measurement.
Indication of testleads connection for Dc/Ac Voltage/
Resistance/Diode/Temperature Measurement
Indication of testlead connection for 10A DC/AC Current Measurement
CHANGING BATTERIES/ FUSE
Changing Battery in the Main Body
SPECIFICATIONS
Basic Functions | other | SP-LT04 |
---|---|---|
Analogue Tracing | ||
Continuity | By Multimeter function | |
Switch Tracing w PoE | ||
Cable Mapping | ||
Switch indicators flashing | ||
Noisy Free Digital Tracing | Digital | Digital /Vibration |
Voltage Testing | By Multimeter function | |
PoE Voltage Measuring | Voltage /Polarity | Voltage /Polarity |
Remote ID Mapping | Optional | Optional |
Analogue Bargraph | ||
NCV Detection | ||
Other Functions | Main Body flashlight, multimeter input jack indicator, LCD |
display, white flashlight, analogue tracing sound adjustable, digital tracing
sensitivity adjustable, low battery indicator, white backlight, energy saving,
tracing distance 3km, analogue tracing signal selectable
Special Functions| |
Multimeter Functions| | 400mV~ 1000V±(0.8%+3)
DC Voltage| | 4V~40 0V±(1.5%+5)
AC Voltage| | 1.0A~10.0A±(1.2%+4)
DC Current| | 1.0A~10.0A±(2.0%+5)
AC Current| | 200~20Ω MΩ±(2%+6)
Resistance| | < 50Ωbuzzer beeps
Continuity| |
Diode| | -20~1000°C±(2.0%+15)
Temperature k type| 400M| 500M
Network Cable Length Measure| |
BNC Cable Length Measure| |
Network Cable Short Open Circuit Test| |
Powered by| Main Body: 1250mA H rechargeable
Lithium Battery/Receiver: 9V Battery
Package| Gift Box/ Manual /Carrying
Bag/ RJ45 Cable /Alligator
Clip Cable| Gift Box/ Manual /Carrying
Bag /RJ45 Cable /Testleads
/k type Temperature Probe
Remote ID Unit is an optical accessories
The specification listed above is only the best specifications
PRODUCT MAINTENANCE
Maintenance
This product is a pre equipment. Please ensure the battery power is good.
Follow the instructions, especially to ensure the multimeter input jack is
plug in correctly. User is not allowed to change the connection. Otherwise,
the product may be damaged and the user may get hurt.
Please follow the instruction to maintain the product:
- Please keep the product away from water, dust. Do not drop the product.
- Do not operate the product in flammable, explosive, high temperature, high humidity and/or strong magnetic field environment.
- Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents.
- Remove the batteries if the product planned to be stored for long period.
- Please recharge the product as soon as possible after the Low Battery Indicator switch on.
Trouble Shooting and Warning
If the product cannot work properly, please check the battery, fuse or the
power switch. Please have the product serviced if the problems cannot be
solved.
All information provided is subject to change without prior notice.
We tried our best to keep the information most updated and correct. If user
find any mistakes, and / or information missing, please contact us or your
distributor.
Our company is not responsible for all damages or hurts caused by the
incorrect operations. All the functions mentioned should not be used as a
reason for special purposes.
ELECTRICAL CHARACTERISTICS
Auto Power Off
Main Body Automatically switch off after no function or button press for 20
minutes
Receiver : Automatically switch off after no function or button press for 10
minutes
Current
Main Body : 40-130mA (subject to the functions)
Receiver : 5100mA
Powered by
Receiver : 9V laminated battery
Main Body : protected 3.7V lithium battery Cable
Tracing Signal Transmission Distance 3km
Safety
Save (Probe can be directly contact non-Hi-Voltage metal conductors
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>