Product Information

Product Specifications

  • Model: EMA4X24DAL, EMA4X36DAL, EMA4X48DAL
  • Size (tons): 2, 3, 4
  • Dimensions H x W x D (in): Varies per model
  • Shipping Weight lbs. (kg): 34 (15), 39 (18), 45 (20)

Features

  • Designed for mobile home downflow gas furnaces
  • Bolt-on TXV metering device factory installed on all models
  • Two condensate drain connections
  • N evaporator design to keep height at a minimum
  • Shipped with condensate drain hose and trap
  • Shipped with fittings and adapter plates
  • Aluminum hairpin/return-bend/fin N coil with high-tech fin design

Product Usage Instructions

Installation

  1. Ensure the unit is compatible with your mobile home downflow gas furnace.
  2. Follow the manufacturer’s instructions for proper installation.
  3. Connect condensate drain connections and ensure proper drainage.
  4. Securely attach fittings and adapter plates as needed.

Maintenance

  1. Regularly check and clean the condensate drain hose and trap to prevent clogs.
  2. Inspect the coil for any debris buildup and clean if necessary.
  3. Monitor the performance of the coil to ensure efficient operation.

FAQs

What is the warranty coverage for the product?

The product comes with a 5-year parts limited warranty. With timely registration, an additional 5-year parts limited warranty can be obtained. Please refer to the warranty certificate for complete details.

What is the CFM range for this product?

The nominal acceptable CFM range is between 350 CFM/ton and 450 CFM/ton. The specific CFM values vary based on the model size.

Are the refrigerant line connections field-installed?

No, the refrigerant line connections come pre-installed with mechanical couplings for easy setup.

FEATURES

  • Designed for mobile home downflow gas furnaces
  • Bolt−on TXV metering device factory installed on all models (equalizer tube brazed in)
  • Two condensate drain connections
  • “N” evaporator design to keep height at a minimum
  • Shipped with condensate drain hose and trap
  • Shipped with fittings and adapter plates
  • Aluminum hairpin/return−bend/fin “N” coil with the latest high−tech fin design

WARRANTY

  • 5 year parts limited warranty
  • With timely registration, an additional 5 year parts limited warranty
  • Applies to original purchaser/homeowner, some limitations may apply. See Warranty certificate for complete details.

Use of the AHRI Certified TM Mark indicates a manufacturer’s participation in the program. For verification of certification for individual products, go to www.ahridirectory.org.

Models

Model| Size (tons)| Dimensions H x W x D (in)| Shipping Weight lbs. (kg)
---|---|---|---
EMA4X24DAL| 2| 12−5/8 x 17−7/8 x 19−9/16| 34 (15)
EMA4X36DAL| 3| 14−11/16 x 17−7/8 x 19−9/16| 39 (18)
EMA4X48DAL| 4| 18−3/4 x 17−7/8 x 19−9/16| 45 (20)

SPECIFICATIONS

Dimensions Inches (English)

Model Size| A| Suction Tube Connection Size| Liquid Tube Connection Size
24| 12−5/8”| 5/8”| 3/8”
36| 14−11/16”| 3/4”| 3/8”
48| 18−3/4”| 3/4”| 3/8”

Dimensions mm (SI Metric)

Model Size| A| Suction Tube Connection Size| Liquid Tube Connection Size
24| 321| (16)| (10)
36| 373| (19)| (10)
48| 476| (19)| (10)

PHYSICAL DATA

PHYSICAL DATA

| Model Size
24| 36| 48
TXV factory installed, hard shut off, bi flow type for heat pump application, non adjustable superheat
R−410A TXV Size| 2 ton| 3 ton| 5 ton

TXV Connections

| TXV−to−coil = Bolt−on 3/4−20 UNF straight thread (factory assembled)
field line set to TXV = 3/8” (10mm) mechanical coupling
equalizer−to−coil = brazed in (factory brazed)
Nominal Acceptable CFM Range (minimum 350 CFM/ton, maximum 450 CFM/ton)
CFM (L/s) − min CFM (L/s) − max| 700 (330)

900 (425)

| 1050 (496)

1350 (637)

| 1400 (661)

1600 (755)

(excessive pressure drop above 1600)

Coil Data (all coils 3 slabs “N” configuration, lanced sine wave bare aluminum fin)
Face Area ft2 (m2)| 4.0 (0.37)| 4.7 (0.44)| 6.0 (0.56)
Each Slab H x W in. (m)| 12 x 16 (305 x 406)| 14 x 16 (356 x 406)| 18 x 16 (457 x 406)
Fins Per Inch| 16| 16| 16
Refrigerant Line Connections (mechanical coupling)
Liquid in. (mm)| 3/8 (10)| 3/8 (10)| 3/8 (10)
Suction in. (mm)| 5/8 (16)| 3/4 (19)| 3/4 (19)

ACCESSORIES

ACCESSORIES

Description| Part Number
Fossil Fuel Kit| AXWR01DFB
PVC Condensate Trap Kit (box of 50)| EBAC01CTK

STATIC PRESSURE DROP ACROSS COIL AT A GIVEN CFM


Coil Size

| CFM

Across Coil

| Static Pressure Drop Across Coil (Inches Water Column)
---|---|---
Dry| Wet
24

2 tons

| 700| 0.182| 0.214
800| 0.233| 0.269
900| 0.290| 0.336


36

3 tons

| 1000| 0.189| 0.236
1100| 0.221| 0.276
1200| 0.259| 0.315
1300| 0.299| 0.361
1400| 0.341| 0.413


48

4 tons

| 1400| 0.322| 0.348
1500| 0.366| 0.396
1600| 0.413| 0.446
1700| |
1800| |

Excessive pressure drop, application not recommended.

COIL MODEL NUMBER IDENTIFICATION GUIDE