Uplink 5530M Cellular Communicators and Programming the Panel Installation Guide
- June 17, 2024
- Uplink
Table of Contents
Uplink 5530M Cellular Communicators and Programming the Panel
Specifications
- Product: Honeywell Vista 21IP
- Compatibility: Uplink’s 5530M Cellular Communicators
- Functionality: Events reporting and control via keybus
Product Usage Instructions
Wiring Uplink’s 5530M Cellular Communicators to Honeywell Vista 21IP:
- Connect the 5530M communicators to the Honeywell Vista 21IP for events reporting and control via keybus.
Programming the Honeywell Vista 21IP Alarm Panel via the Keypad
- Enable Contact ID reporting by following the steps provided in the manual.
- Access the programming menu by entering the specified code.
- Configure primary phone settings, account numbers, phone system menu, reporting format, and other necessary parameters.
- Set Open Report code, ARM Away/Stay reporting code, and other relevant codes as needed.
Program KeySwitch Zone and Status Output:
- Access the programming menu on the keypad by entering the designated code.
- Navigate to zone programming menu and select the desired zone for programming.
- Configure zone parameters such as Zone Type, Report Code, Response Time, and more.
- Set output functions, activation by Zone Type, assign outputs to partitions, and save settings accordingly.
Program the Panel for Upload/Download (UDL)
- Enter the programming menu on the keypad using the specified code.
- Adjust the Number of rings to answer to 1 for Upload/Download functionality.
- Save settings and exit to complete the UDL setup.
Frequently Asked Questions (FAQ)
-
Q: How do I wire the 5530M communicators to the Honeywell Vista 21IP?
-
A: Follow the wiring instructions provided in the manual for events reporting and control via keybus.
-
Q: How can I enable Contact ID reporting on the Honeywell Vista 21IP?
A: Access the programming menu on the keypad and follow the steps outlined to enable Contact ID reporting. -
Q: What is the process to program keyswitch zone and status output?
A: Refer to the programming instructions in the manual to set up keyswitch zones and configure status outputs.
Honeywell Vista 21IP
Wiring Uplink’s 5530M Cellular Communicators and Programming the Panel
CAUTION
- It is advised that an experienced alarm installer programs the panel as further programming may be required to ensure proper performance and use of the full functionality.
- Do not route any wiring over circuit board.
- Full panel testing, and signal confirmation, must be completed by the installer.
NEW FEATURE: For 5530М Communicators, the status of the panel can be
retrieved not only from the status PGM but now also from the Open/Close
reports from the dialler.
IMPORTANT NOTE: The Open/Close reporting needs to be enabled during the
initial pairing procedure.
NOTE: We recommend connecting the Output to Zone 3 (terminal 12), because
the first two zones maintain constant voltage level of +12V, which may damage
the output of the communicators.
Wiring the 5530M communicators to Honeywell Vista 21IP for events reporting and control via keybus:
Wiring the 5530M communicators to Honeywell Vista 21IP for events reporting and control via keyswitch:
Wiring the 5530M with UDM to Honeywell Vista 21IP for remote upload/download:
Programming the Honeywell Vista 21IP Alarm Panel via the Keypad Enable Contact ID reporting:
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Disarmed | 4112,8,00 | To enter the programming menu |
Installer code 20 | *41 | To go to primary phone setting |
Pri. Phone | 123456* | Enter phone number (123456 is an example) * to save |
Sec. Phone | *43 | To go to primary account number |
SubID. Pri. | 1234* | Enter account number (1234 is an example) * to save |
SubID. Sec. | *47 | To go to phone system menu |
Phone Sys. | 1 | Press 1 to select tone dialing |
Rep Form Pri/Sec | *48 | To go to reporting format |
Rep Form Pri/Sec | 77 | To choose Ademco Contact ID reporting |
Split / Dual | *65 | To go to Open Report code |
Open Rpt. | 111 | To enable Open report code for Partition 1, 2 and in general |
Awy/Sty Rpt. | *66 | To go to ARM Away/Stay reporting code |
Awy/Sty Rpt. | 111111 | To enable Away/Stay ARM reporting code for Partition 1,2 |
and in general
---|---|---
RF LB Rpt.| 70| To go to Alarm/Restore reporting code
Alm Res Rpt| 1| To enable alarm/Restore reporting code
Trb Res Rpt| 84, 3| To set Auto-Stay Arm for both Partitions
| *99| To exit and save
Program keyswitch zone and status output
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Disarmed | 4112,8,00 | To enter the programming menu |
Installer code | *56 | To go to zone programming menu |
Set to confirm | 1 | To enter the menu |
Enter Zn. Num. | 03* | To enter zone 3 programming |
Zn ZT PRC HW:RT | * | To enter the first parameter input section |
03 Zone Type | 77* | To select keyswitch |
03 Report Code | 0000* | To disable reporting code for zone activation |
03 Resp. Time | 1* | To set response time to 1 second |
Zn ZT PRC HW:RT | * | To confirm settings and go to next menu |
Program Alpha? | 0 | To go to next menu |
Enter Zn. Num. | 00 | To quit |
Enter * or # | *80 | To go to output programming menu |
Output Funct. # | 01* | To set Output 1 |
01 AEP Trig | * | To go to next menu |
01 Activated by | 2* | To select Activate by Zone Type |
01 Enter Zone Type | 78* | To choose Keyswitch RED (Armed) |
Partition No. | 1 | To assign Output 1 to Partition 1 |
Enter Output No. | 18* | To select output 18 (pin 5 on the 8 pin connector as |
shown on the 1st page)
01 AEP Trig| | To save settings
Output Funct. #| 00| To quit
Enter or #| *99| To save and quit
Programming the Honeywell Vista 21IP Alarm Panel via the Keypad for remote Upload/Download (UDL)
Program the Panel for Upload/Download (UDL)
Display | Keypad Entry | Action Description |
---|---|---|
Disarmed | 4112,8,00 | To enter the programming menu |
Installer code | *95, 1 | To set “Number of rings to answer” to 1 |
Pager 1 Phn No. | *99 | To save and quit |
NOTE
If the software says that the CSID doesn’t match, *96 while in programming
mode initializes CSID and account number (assigns them their default values).
Programming an Alpha Keypad Address\
Keypad Display | Keypad Entry | Action Description |
---|---|---|
Disarmed | 4112,8,00 | To enter the programming menu. |
Installer code | *194 | To enter Keypad Address 21 |
Keypad Addr.21 | 1,0 | To enable the Alpha Keypad Address 21 for 1st partition |
Keypad Addr.22 | *195 | To enter Keypad Address 22 |
Keypad Addr.22 | 2,0 | To enable the Alpha Keypad Address 22 for 2nd partition |
Note: This address is optional – only if 2 partitions are used
Keypad Addr.23| *99| To save and quit
Switching from Keyswitch to Keybus
- Wire the device to the panel as described on the respective wiring scheme above
- Use the Sync with Panel from the Settings menu of the Uplink mobile app.
The device will apply the new configuration automatically.
NOTE 2 : When switching the wiring of the device, make sure that the
device is not powered on.
NOTE 3 : When synchronizing or disabling and enabling the
Arming/Disarming feature from the mobile application, make sure:
- the device is powered and connected to cellular network;
- the panel is not in programming menu/mode.
After enabling the Arming/Disarming feature it may take up to 1 minute for the device to apply the new configuration.