SLV 153560 Eutrac 3 Phase Track System Instruction Manual
- June 16, 2024
- SLV
Table of Contents
SLV 153560 Eutrac 3 Phase Track System Instruction Manual
Technical Details are subject to change.
Use as directed
Use only with corresponding track system.
Safety class II (2) – Safety insulated – Connection without
protective conductor.
Operate only in dry indoor area.
Do not strain mechanically or expose to strong dirt contamination.
Do not direct light exit on the track or other luminaires.
Minimum distance of light source to illuminated surface: 0,5 m.
Lamp replacement
Disconnect luminaire from mains and let it cool down.
Suitable light sources: GU10, 50W max.
Care / Storage
Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Store dry and clean.
Installation
Disconnect the complete system from the power supply.
Use only described accessories.
Note the distance to the illuminated surface.
When attaching luminaires pay attention to the admissible mechanical load of
the tracks.
Do not use force when inserting the adapter.
Install as shown in the figure.
Install and operate at a minimum height of 2,50 m only when using halogen
lamps.
Adapter may be inserted only in one direction.
Turn locking device (A) to the side.
Turn phase adjuster (B) to position “OFF”.
Insert adapter into track.
Secure locking device.
Choose desired phase turning the phase adjuster.
Check secure fixation and proper function!