SLV 152380 Recess Mounted Luminaire Instruction Manual

June 16, 2024
SLV

152380 Recess Mounted Luminaire

SLV 152380 Recess Mounted Luminaire - icon

INSTRUCTION MANUAL PART A

Recess-Mounted Luminaire
152380
152381 SLV 152380 Recess Mounted Luminaire - fig

The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
The light source is only exchangeable by a professional.
Technical Details are subject to change.

  SLV UK
Unit E Chiltern Park
Boscombe Road, Bedfordshire
LU5 4LT

Operating Manual PART B

Recess-Mounted Luminaire
152380 …81
Read manual carefully and keep for further use!
Safety advices for installation and operation.
Disregard may lead to danger of life, burning or fire!
Any works on the electrical connection only by electrician.
Do not alter or modify the product.
Do not fasten anything on the product.
Do not cover the product.
Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
Take measures that children get not harmed by the product.
Do not stare into the active light source.
Additional safety advices = **
Use as directed
Safety class III (3) **
– Operated with safety extra-low voltage.
Operate only firmly fixed on an even surface.
Operate only on normal or not inflammable surfaces.
Operate only in dry indoor area.
Do not strain mechanically or expose to strong dirt contamination.
Admissible ambient temperature(ta): max. 40°C.

Light Source

The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
This product contains a light source of the energy efficiency class E.

Care / Storage

**** Disconnect product from mains and let it cool down.
Clean external surfaces regularly with a slightly moistened (water) cloth.
Store dry and clean.

Installation

**** Switch off mains / fixed connection cable!
Use only described accessories.
Only suited for recessed wall and ceiling installation.
Keep sufficient distance to inflammable materials.
Ensure sufficient aeration.
: Do not cover, especially not with insulating materials.
Install as shown in the figure.

Electrical connection

Use only a suitable LED driver (e.g. SLV 464091).
Output current(constant): 500mA / Power: 7,5W min.
Red wire → (+) Terminal
Black wire → (-) Terminal
Establish a serial connection when connecting more than one luminaires to one LED driver.
**** Check secure fixation and proper function!

© 28.12.2022 SLV GmbH, Daimlerstr. 21-23, 52531
Übach-Palenberg, Germany,
Tel. +49 (0)2451 4833-0.