Product Information
- Specifications
- Model: 1007667
- IP Rating: IP65
- Input Voltage: 220V-240V ~50/60Hz
- Power Consumption: 15W
- Luminous Flux: 900 lm (2700K), 1050 lm (3000K)
- Color Rendering Index (CRI): >80
- Dimensions: 13 x 13 x 9 cm
- Weight: 1.23 kg
Product Usage Instructions
- Safety Advice
- Read the manual carefully and keep it for further use. Failure to follow the safety advice may lead to danger of life, burning, or fire.
- Any works on the electrical connection should only be carried out by an approved electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Operate the product only with intact protection glass.
- If you suspect a defect or malfunction, take the product out of service and contact your dealer or a qualified electrician.
- Ensure that children are not harmed by the product.
- Avoid staring into the active light source.
- Additional Safety Advice
- Use the product as directed.
- The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician, or a comparable qualified person.
- Disconnect the product from mains and let it cool down before cleaning.
- Clean external surfaces regularly with a slightly moistened cloth (water).
- Do not clean with a pressure washer.
- Keep openings providing aeration or drainage free from obstructions.
- Avoid exposing the product to acidic surroundings, high salt content in the air, cleaning agents, fertilizer, thawing salt, or chemicals.
- Store the product in a dry and clean place.
- Installation
- The installation of this product requires expert knowledge and should only be carried out by an approved electrician, considering local and national regulations.
- Switch off mains/fixed connection cable before installation.
- Use only described accessories and suitable fastening materials.
- This product is only suited for wall surface mounting.
- Follow local regulations for outdoor installations.
- Do not seal the product yourself with silicone.
- Install according to the declared IP type.
- Refer to the figure provided for installation guidance.
- Suitable Dimmer: Trailing-edge phase dimmer (Code C). Follow the manufacturer’s instructions for dimmer usage.
- Electrical Connection
- When connecting the product electrically, follow these instructions:
- Direct the fixed wiring with its complete insulation at least 15 mm into the housing.
- Equip flexible wire ends with suitable wire ferrules.
- Connect the live conductor to the terminal L, the neutral conductor to the terminal N, and the protective conductor to the Earth terminal.
- Check for secure fixation and proper function after connection.
- FAQ
- Q: Who should replace the light source?
- A: The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician, or a comparable qualified person.
- Q: How should I clean the product?
- A: Disconnect the product from mains and let it cool down. Clean external surfaces regularly with a slightly moistened cloth (water). Do not use a pressure washer.
- Q: Can I install the product myself?
- A: The installation of this product requires expert knowledge and should only be carried out by an approved electrician, considering local and national regulations.
- Q: What dimmer should I use?
- A: The suitable dimmer for this product is a trailing-edge phase dimmer (Code C). Please follow the manufacturer’s instructions for dimmer usage.
FEATURES
HARDWARE
PART A Wall Light
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.
Operating Manual
Operating Manual PART B Wall Light 1007667
- Read manual carefully and keep for further use!
- Safety advices for installation and operation.
- Disregard may lead to danger of life, burning or fire!
- Any works on the electrical connection only by electrician.
- Do not alter or modify the product.
- Do not fasten anything on the product.
- Do not cover the product.
- Operate only with intact protection glass.
- Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician.
- Take measures that children get not harmed by the product.
- Do not stare into the active light source.
- Additional safety advices =
Use as directed
- Safety class I ( ) – Connection with protective conductor.
- Operate only firmly fixed on an even surface.
- Operate only on normal or not inflammable surfaces.
- Do not strain mechanically or expose to strong dirt contamination.
- IP65: Protection against dust (dust-tight) – Protection against jetted water from all directions.
- Admissible ambient temperature(ta): -20°C …+40°C.
Light Source
- The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.
- This product contains a light source of the energy efficiency class E.
- Reference control setting: 3000K
Care / Storage
- Disconnect product from mains and let it cool down.
- Clean external surfaces regularly with a slightly moistened (water) cloth.
- Do not clean with pressure washer.
- Openings providing aeration or drainage must be kept free.
- The following influences may have unwanted effects on the product: acidic surrounding, high salt content in the air, cleaning agents, fertilizer, thawing salt, chemicals.
- Store dry and clean.
Installation
- Switch off mains / fixed connection cable!
- Use only described accessories.
- Use only suitable fastening materials.
- Only suited for wall surface mounting.
- Follow local regulations for outdoor installations.
- Do not seal the product yourself (e.g. with silicone).
- Install according to declared IP type.
- Install as shown in the figure.
- Suitable Dimmer: Trailing-edge phase dimmer (Code C). Note manufacturers instructions.
Electrical connection
Direct the fixed wiring with its complete insulation at least 15 mm into the housing.
Equip flexible wire ends with suitable wire ferrules!
- Live conductor Terminal L
- Neutral conductor Terminal N
- Protective conductor Earth terminal
- Check secure fixation and proper function!