SLV 1007612 Wall Light Instruction Manual

June 16, 2024
SLV

SLV 1007612 Wall Light Instruction Manual
SLV 1007612 Wall Light

Installation Instruction

Installation Instruction
Installation Instruction

Electric Icon
The installation requires expert knowledge and may be carried out only by an approved electrician under consideration of local and national regulations!

Instruction
The light source is only exchangeable by a professional. The separate control unit is only exchangeable by a professional.

Technical Details are subject to change.

SLV UK
Unit E Chiltern Park Boscombe Road, Bedfordshire
LU5 4LT

Read manual carefully and keep for further use!

Safety advices for installation and operation. Disregard may lead to danger of life, burning or fire!

Any works on the electrical connection only by electrician. Do not alter or modify the product. Do not fasten anything on the product. Do not cover the product. Operate only with intact protection glass. Take out of service when suspecting a defect or malfunction and contact your dealer or a qualified electrician. Take measures that children get not harmed by the product. Do not stare into the active light source.
Additional safety advices = ****

Use as directed

Safety class I (1) – Connection with protective conductor. Operate only firmly fixed on an even surface. Operate only on normal or not inflammable surfaces. Operate only indoors. Do not strain mechanically or expose to strong dirt contamination. Admissible ambient temperature(ta): -20°C …35°C.

IP44: Protection against foreign objects > Ø 1,0mm – Protection against splashing water from all directions.

Light Source

The light source of this luminaire may only be replaced by the manufacturer, an authorized service technician or a comparable qualified person.

This product contains a light source of the energy efficiency class E.

Care / Storage

**** Disconnect product from mains and let it cool down. Clean external surfaces regularly with a slightly moistened (water) cloth. Store dry and clean.

Installation

**** Switch off mains / fixed connection cable! Use only described accessories. Use only suitable fastening materials. Only suited for wall surface mounting. Install according to declared IP type. Install as shown in the figure.

Electrical connection

Direct the fixed wiring with its complete insulation at least 15 mm into the housing

Equip flexible wire ends with suitable wire ferrules!
Live conductor  Terminal L
Neutral conductor Terminal N
Protective conductor Earth terminal

**** Check secure fixation and proper function!

Symbol Instruction
Symbol Instruction