ELKAY EZFMK Filter Maintenance Kit Instruction Manual

June 15, 2024
ELKAY

ELKAY-logo

ELKAY EZFMK Filter Maintenance Kit

ELKAY-EZFMK-Filter-Maintenance-Kit-product

Product Information

Specifications:

  • Product Name: EZ Filter Maintenance Kit (EZFMK)
  • Application: Indoor use only
  • Tools Required (not provided): Gloves, Safety Glasses, 5/16 Nut Driver or Flat Head Screwdriver

Product Usage Instruction

Installation Procedure:

  1. Remove the existing lower wrapper on the cooler by removing the (4) screws using a 5/16 nut driver.

  2. If you are replacing the filter, do that now with the lower wrapper removed. Refer to the Filter Replacement Instructions in Section 2, Step 3 or the instruction sheet included with the replacement filter. If not, skip to the next step.

  3. Unpack the new side access wrapper from the box, peel off the protective wrap, and install it using the (4) supplied screws.
    CAUTION: Do not operate the unit with the access panel removed.

  4. Dispose of the old lower wrapper. It can be brought to a scrap metal recycler. Please check with your local waste hauler before placing scrap metal into a municipal recycling cart.

Future Filter Replacement Steps (Side Access):

  1. Remove the (4) security Torx screws using a Torx T25 bit (included).
  2. Take the side access panel and place it back on the opening of the side access wrapper. Align the access panel by inserting the alignment pins on the back side of the panel into the alignment slots above the wrapper frame opening.
  3. Refer to the following filter replacement steps:
  4. CAUTION: To avoid the danger of an electric shock hazard, disconnect the power to your unit before replacing the filter. Turn off the water supply and dispense water to relieve pressure.
  5. Turn the used filter counterclockwise 1/4 turn to remove it from the filter head.
  6. Remove the cap from the new filter and use it to seal the used filter.
  7. Write the date of filter installation on the label. Insert the new filter into the existing filter head and turn it fully clockwise so that the label with the date is visible.
  8. Turn on the water supply and run water for 10 minutes to purge air and fine carbon particles from the filter.
  9. Reset the filter monitor, if necessary. See the Use Manual of the dispenser for instructions.
  10. Once the access panel is set in place, refasten the (4) security Torx screws starting by hand and firmly secure each screw in place. CAUTION: Do not operate the unit with the access panel removed.

FAQ:

  • Q: Can I use this product outdoors?
    A: No, this product is designed for indoor use only.

  • Q: What tools do I need for installation?
    A: You will need gloves, safety glasses, and either a 5/16 nut driver or a flat head screwdriver.

  • Q: Can I replace the filter myself?
    A: Yes, you can replace the filter by following the filter replacement steps provided in the user manual.

  • Q: What should I do with the old lower wrapper?
    A: You can bring the old lower wrapper to a scrap metal recycler. Please check with your local waste hauler for proper disposal methods.

IMPORTANT
THIS IS AN INDOOR APPLICATION ONLY. ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON.

ELKAY-EZFMK-Filter-Maintenance-Kit-fig-1

TOOLS REQUIRED

BUT NOT PROVIDED:

GLOVES
SAFETY GLASSES 5/16 NUT DRIVER (HIGHLY RECOMMENDED) OR FLAT HEAD SCREWDRIVER.

IMPORTANT!
INSTALLER PLEASE NOTE.

INSTALLER
To ensure you install this Kit easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES.

EZFMK Rough-in

ELKAY-EZFMK-Filter-Maintenance-Kit-fig-2

Installation Procedure

  1. Remove the existing lower wrapper on the cooler by removing the (4) screws using a 5/16 nut driver.

  2. If you are replacing the filter, do that now with the lower wrapper removed. Refer to the Filter Replacement Instructions in Section 2, Step 3 or the instruction sheet included with the replacement filter. If not, skip to the next step.

  3. Unpack the new side access wrapper from the box, peel off the protective wrap, and install it using the (4) supplied screws.
    CAUTION
    Do not operate the unit with the access panel removed. Note:
    While the side access wrapper is being secured, verify the upper profile (left, front, and right side) of the wrapper frame slides up and under the plastic basin shroud assembly for a tight fit (as shown).

  4. Dispose of the old lower wrapper. It can be brought to a scrap metal recycler. Please check with your local waste hauler before placing scrap metal into a municipal recycling cart.

Future Filter Replacement Steps

Future Filter Replacement Steps (Side Access)

  1. Remove (4) security Torx screws using Torx T25 bit (included).

  2. Remove the side access panel and set it aside.

  3. Refer to the following filter replacement steps.
    CAUTION
    To avoid the danger of an electric shock hazard, disconnect the power to your unit before replacing the filter.

    • Turn off the water supply; dispense water to relieve pressure.
    • Turn used filter counterclockwise 1/4 turn to remove it from the filter head.
    • Remove the cap from the new filter and use it to seal the used filter.
    • Write the date of filter installation on the label. Insert the new filter into the existing filter head and turn fully clockwise so the label with the date is visible.
    • Turn on the water supply and run the water for 10 minutes to purge air and fine carbon particles from the filter.
    • Reset the filter monitor, if necessary. See the Use Manual of the dispenser for instructions.
  4. Take the side access panel and place it back on the opening of the side access wrapper. Align the access panel by inserting the alignment pins on the back side of the panel into the alignment slots above the wrapper frame opening (as shown).

  5. Once the access panel is set in place, refasten the (4) security Torx screw bits starting by hand, and firmly secure each screw in place.

CAUTION
Do not operate the unit with the access panel removed.

Replacement Parts

Replacement Parts

Part Number| Description
2000000859| Wrapper Frame Assembly
2000000853| Kit – Replacement Filter Access Door
| W/Hardware
75520C| Bit-Pinned Torx T-25
51300C| Replacement Filter – 3000 Gallons

  • FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.834.4816
  • REPAIR SERVICE INFORMATION TOLL-FREE NUMBER 1.800.260.6640

ELKAY MANUFACTURING COMPANY

  • Address: 1333 BUTTERFIELD ROAD SUITE 200 DOWNERS GROVE, IL 60515
  • Phone: 630.574.8484
  • Web: www.elkay.com.

PRINTED IN U.S.A.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ELKAY User Manuals

Related Manuals