COOPER IB51443322 Outdoor Reflector Integrated LED Installation Guide

June 15, 2024
Cooper

COOPER-logo

COOPER IB51443322 Outdoor Reflector Integrated LED

Product Information

Specifications

  • Model Number : IB51443322
  • Power : 15W/27W/40W/65W
  • Dimensions : 176.5mm x 30mm x 56mm (for 15W/27W), 211.5mm x 30mm x 56mm (for 40W/65W)
  • Mounting Options : Knuckle Mount, Ground Stake Mount, Pole Top Fitter Mount, Slipfitter Mount, Yoke Mount, Trunnion Mount

Product Usage Instructions

Knuckle Mount Installation

  1. Install the fixture by attaching the knuckle bracket to a weatherproof Junction Box (supplied by others).
  2. Secure the fixture using a 1/2 locknut.
  3. Make electrical connections from the supply ground (L/N/GND) lead to the fixture ground (L/N/GND) lead following the National Electrical Code and applicable local codes and ordinances.
  4. Aim the fixture by loosening the screw on the knuckle of the filter and rotating it to the desired tilt angle.
  5. Re-tighten the screw to 11 ft-lbs.
  6. Seal the 1/2 NPS thread using weatherproof silicone sealant.

Slipfitter Mounting

  1. Connect the fixture lead wires to L/N/GND.
  2. Install the slipfitter on the pole and tighten the set screws to 11 ft-lbs.
  3. Loosen and remove the cover plate screws and carefully set aside the cover plate and screws.
  4. Loosen the center bolt and adjust the angle of the slipfitter arm as needed.
  5. Re-tighten the center bolt to 12 ft-lbs.
  6. Re-install the cover plate and screws.

Yoke Mounting

  1. Mount the fixture onto a surface using the hole pattern provided on the yoke bracket.
  2. Make electrical connections from the supply ground (L/N/GND) lead to the fixture ground (L/N/GND) lead following the National Electrical Code and applicable local codes and ordinances.
  3. Aim the fixture by loosening the 2 screws on either side of the fixture and rotating it to the desired tilt angle.
  4. Retighten the 2 screws to 11 ft-lbs. for 25W and 65W fixtures.

Trunnion Mounting

  1. Connect the wires to L/N/GND.
  2. Mount the fixture to a surface using the hole pattern provided.

FAQ

  • Q: Who should perform the installation and maintenance of this product?
    A: Installation and maintenance of this product must be performed by a qualified electrician.

  • Q: What precautions should be taken before starting installation or maintenance?
    A: Make sure power is OFF by disconnecting it at the fuse or circuit breaker.

  • Q: What should I do if the fixture becomes damaged or unstable?
    A: If the fixture becomes damaged or unstable, it should be properly installed to ensure stability and safety.

Installation Instructions – LSF
IMPORTANT : Read carefully before installing product. Retain for future reference. Failure to comply with these instructions may result in death, serious bodily injury and property damage.

WARNING

  • Risk of Fire, Electrical Shock, Cuts or other Casualty Hazards – Installation and maintenance of this product must be performed by a qualified electrician. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved.

  • Risk of Fire and Electric Shock – Make certain power is OFF before starting installation or attempting any maintenance. Disconnect power at fuse or circuit breaker.

    • Risk of Fire – Refer to product label for specific minimum supply conductor requirements.
  • Risk of Burn – Disconnect power and allow fixture to cool before handling or servicing.

  • Risk of Personal Injury- Fixture may become damaged and/or unstable if not installed properly.

DISCLAIMER OF LIABILITY : Cooper Lighting Solutions assumes no liability for damages or losses of any kind that may arise from the improper, careless, or negligent installation, handling or use of this product.

NOTICE : Green ground wire provided in proper location. Do not relocate.

ATTENTION Receiving Department : Note actual fixture description of any shortage or noticeable damage on delivery receipt. File claim for common carrier (LTL) directly with carrier. Claims for concealed damage must be filed within 15 days of delivery. All damaged material, complete with original packing must be retained.

Safety : This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to ensure personal safety.

APPLICATIONS : This lighting fixture is designed for outdoor lighting applications, and should not be used in area of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo control or shorting cap (if so equipped). Best results will be obtained if installed and maintained according to the following instructions.
Suitable for mounting within 1.2 m (4 ft) of the ground

Installation Instructions – LSF

Installation Guide
1/2” NPS Knuckle Mount optional ground stake mount pole top fitter mount

  1. Install the fixture by knuckle bracket on the weatherproof Junction Box (supplied by others), and secure it by 1/2” locknut (figure 1)
  2. Make electrical connections from the supply ground (L/N/GND) lead to fixture ground (L/N/GND) lead respectively, making sure to follow all National Electrical Code and all applicable local codes and ordinances.
  3. Aim fixture by loosening screw on knuckle of filter and rotating fixture to desired tilt angle, Re-tighten screw to 11 ft-lbs.
  4. Seal the 1/2” NPS thread using weatherproof silicone sealant.

Figure 2

Slipfitter Mounting

  1. Connect the fixture lead wires to L/N/GND
  2. Install the slipfitter on the pole and tighten the set screws to 11 ft-lbs.
  3. Loosen and remove the cover plate screws and carefully set aside the cover plate and screws (figure 3).
  4. Loosen center bolt and adjust angle of the slipfitter arm as needed.
  5. Re-tighten the center bolt to 12 ft-lbs.
  6. Re-install the cover plate and screws.

Figure 1.

Yoke Mounting

  1.  Mount fixture onto surface using the hole pattern provided on the yoke bracket (figure 2).
  2.  Make electrical connections from the supply ground (L/N/GND) lead to fixture ground (L/N/GND) lead respectively, making sure to follow all National Electrical Code and all applicable local codes and ordinances.
  3. Aim fixture by loosening the 2 screws on either side of the fixture and rotating fixture to desired tilt angle. Retighten the 2 screws to 11 ft-lbs. for 25W and 65W fixtures.

Figure 3

Trunnion Mounting

  1. Connect the wires to L/N/GND
  2. Mount fixture to surface using the hole pattern provided on the trunnion bracket (figure 4).
  3. Loosen center bolts and set screw
  4. Rotate fixture to desired aiming position and tighten center bolts to 11 ft-lbs.
  5. Tighten set screw to 11 ft-lbs.
  6. Refer to wiring diagrams for power connection.

Figure 4

Power and CCT selectable version

  1. Remove the 1/2” screw plug on the bottom of the fixture.
  2. Select Power(White) and CCT(Black) by sliding the respective switch to the desired value according to the figure.
  3. Reinstall the screw plug in the bottom of the figure. Tighten to 20 in-lbs.

Figure 5

Troubleshooting

Turn off power before continuing

  1. Light does not come ON.
  2. Check if circuit breaker tripped
  3. Confirm wall switch is ON.
  4. Check that if the wiring to the unit is loose.
  5. Check that the line voltage at the fixture is correct.
  6. Confirm wiring is properly secured.
  7. Light cycles ON and OFF continuously
  8. Check the photocell if sensing reflected light.
  9. Light stays ON.
  10. Be sure the photocell, if used, is functioning properly.
    If the light still does not work after checking, contact customer service.

Wiring Diagram
For 1-10V dimming version, please check wiring diagram below.

FCC Statement

Note : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Warranties and Limitation of Liability

Please refer to www.cooperlighting.com/global/resources/legal for our terms and conditions.

  • Cooper Lighting Solutions
    1121 Highway 74 South Peachtree City, GA 30269
    P : 770-486-4800
    www.cooperlighting.com

  • Canada Sales
    5925 McLaughlin Road Mississauga, Ontario L5R 1B8
    P : 905-501-3000
    F : 905-501-3172
    © 2022 Cooper Lighting Solutions All Rights Reserved
    Printed in USA
    Publication No. IB51443322 December 9, 2022

  • Cooper Lighting Solutions is a registered trademark.
    All trademarks are property of their respective owners.

  • Product availability, specifications, and compliances are subject to change without notice

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Cooper User Manuals

Related Manuals