alpha DPX 1350W Down Converter Instructions
- June 15, 2024
- Alpha
Table of Contents
on EnerSys® company
DPX 1350W
Downconverter
DPX 1350W Down Converter
- IP68 rated enclosure provides maximum flexibility for various installation options (pole, wall, underground, or aerial)
- Extended operating temperature range up to 65°C (149°F)for deployment in the harshest outdoor environments
- Remote monitoring via the Cordex® CXC HP system controller offers advanced monitoring and control of eachof the four output channels including power cycling, load shedding, voltage, and current readings
- Class 4 rated input circuit for fault managed safety
- Four outputs to power multiple devices from a single source
The DPX 1350W Downconverter is part of the distributed power transport product
family specifically engineered using the new Alliance for Telecommunications
Industry Solutions (ATIS) fault managed power distribution technology. The DPX
1350W Downconverter converts the incoming (±190 Vdc) voltage to 48 Vdc to
power a multitude of communications devices such as small cells, remote radio
heads (RRH), and IoT devices.
The DPX 1350W Downconverter provides four isolated outputs from a single 12
AWG (4 mm²) or 14 AWG (2.5 mm²) hybrid or copper only cable input. Each
isolated output can deliver a maximum of 450 watts at 48 Vdc or 1350 watts of
total power to remote
telecommunication equipment. The DPX 1350W Downconverter provides full power
up to 55°C (131°F).
Distributed power transport architecture enables operators to deploy their
network faster by eliminating the need to have AC utility power at each small
cell location. At a central location, the central power hub converts the
incoming AC power to fault managed power which is transported over a hybrid or
copper only cable to a disconnect box and then to a down converter device
located approximately 6000 ft away. This reduces installation and operating
expenses, and provides flexibility related to site selection for the
installation of the remote communications equipment.
DPX 1350W Downconverter
PN: 0120084-001
Electrical
Input Voltage| ±145 Vdc to ±200 Vdc
Output Voltage| –54 Vdc
Output Power| Total: 1350 W
Per Port: 450 W
Output Current| 9.4 A
Load Regulation| <±3%
Acoustic| 0 dB
Features
Adjustments| •Individual output load shedding
•Individual output power cycling
•Individual output power
•Remote firmware upgrade
---|---
Protection| •Safe start function
•Current limit and short circuit
•Reverse polarity
•Output high voltage shutdown
•Power limiting
•Over-temperature
Monitoring| •Individual output voltage
•Individual output current
Mechanical
Dimensions H × W × D | 203.2 × 457.2 × 109 mm (8 × 18 × 4.3 in.) |
---|---|
Weight | 9 kg (19.8 lb) |
Connections | Input: 1 |
Output: 4 (isolated)
Environmental
Temperature| Operation: –40 to 65°C (–40 to 149°F); full rated output up to
55°C (131°F)
---|---
| Storage: –40 to 85°C (–40 to 185°F)
Relative Humidity| 5 to 95%
Elevation| Up to 3,000 m (9,842 ft)
Enclosure Rating| IP68
Type 6P
Agency Compliance
Safety| •ATIS (Pending)
•IEC/EN/CSA/UL 62368-1 (Pending)
•CE Mark (Pending)
•UKCA Mark (Pending)
---|---
EMC| Emissions:
•ETSI 300 386 (Pending)
•CFR47 (FCC) Part 15 Class A (Pending)
•ICES-003 Class A (Pending)
Immunity:
• ETSI 300 386 (Pending)
• EN 61000-4-2, 4-3, 4-4, 4-5, 4-6 (Pending)
• ANSI/IEEE C62.41 CatB3 (Pending)
EnerSys World Headquarters
2366 Bernville Road,
Reading, PA 19605, USA
Tel +1-610-208-1991
+1-800-538-3627| EnerSys EMEA
EH Europe GmbH,
Baarerstrasse 18,
6300 Zug
Switzerland| EnerSys Asia
152 Beach Road,
Gateway East Building #11-08,
Singapore 189721
Tel: +65 6416 4800
---|---|---
09/2023
0480090-00 REV A