alpha FC-AA02-A V3-3B Ceiling Fan Instruction Manual
- May 15, 2024
- Alpha
Table of Contents
- alpha FC-AA02-A V3-3B Ceiling Fan
- Product Information
- Product Usage Instructions
- FAQ
- Safety Precaution
- Parts & Accessories
- Installation Instruction
- Power Supply Connection
- Circuit Diagram
- Transmitter Learning Process
- Transmitter Function
- Function of Forward & Reverse
- Maintenance
- Technical Specifications
- Customer Service Centre
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
alpha FC-AA02-A V3-3B Ceiling Fan
Product Information
Specifications
- Model: FC-AA02/A, FC-AA04/A, FC-AA06/A, FC-AA07/A
- Alt. Name: V3-3B/52 LED, V3-3B/46 LED, V3-3B/40 LED, V3-3B/28 LED
- Type: Ceiling Fan
- Version: 2023.V1
Product Usage Instructions
Safety Precautions
Before installing or using the ceiling fan, please carefully read and adhere to the safety precautions mentioned in the manual. Some key points include:
- Installation and maintenance should be done by qualified individuals.
- Ensure proper grounding to prevent hazards.
- Tighten blades securely to avoid accidents.
- Children should not play with the appliance unsupervised.
- Always confirm power supply is switched OFF before any work.
FAQ
- Q: What should I do if the ceiling fan shows abnormal oscillating movement?
- A: Stop using the fan immediately and contact the manufacturer or a qualified service agent for assistance.
- Q: Can children operate the ceiling fan on their own?
- A: Children should be supervised while operating the ceiling fan to ensure their safety. It is recommended not to allow unsupervised usage by children.
Safety Precaution
Warning
- Installation and maintenance work shall only be performed by qualified persons, familiar with local code and regulation, and experienced with this type of appliance.
- All field wiring must be installed under the national wiring regulation.
- Ensure that the rated voltage of the unit corresponds to that of the name plate before commencing wiring work according to the wiring diagram.
- The appliance must be permanently connected to the electricity supply through a double pole switch having a contact separation of at least 3mm in all poles.
The unit must be GROUNDED to prevent possible hazards due to insulation
failure.
The earth wire is approximately 60mm longer than the safety wire. This is to
ensure at the event whereby the suspension system fails, the (L) and (N) wires
will break leaving the fan to remain earthed to prevent electrocution.
Tighten the blade firmly using a screwdriver.
- Blades that are detached from the unit during operation will cause serious injuries and property damage.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliances.
- Confirm that the power supply has been switched OFF before installing or servicing the unit. Ensure that the blade is fully static before doing any maintenance work.
STOP using the ceiling fan when any abnormality or failure occurs.
If unusual oscillating movement is observed, immediately stop using the
ceiling fan and contact the manufacturer, its service agent or suitably
qualified persons.
CAUTION
- Please take note of the following important points when installing.
- The fixing means for attachment to the ceiling such as hooks or other devices shall be fixed with a sufficient strength to withstand 4 times the weight of the ceiling fan.
- The mounting of the suspension system shall be performed by the manufacturer, its service agent or suitably qualified persons.
- The fan is to be installed so that the blades are more than 2.5m above the floor.
Safety cord should not be longer than the earthing conductor.
- Should failure of the suspension system occur, the support of the fan must not rely on the earthing conductor. The earthing terminal in the fan assembly should be such that should any part of the suspension system fall off, the body of the fan assembly shall effectively earthed.
Ensure that the unit’s panel is closed after service or installation.
- Unsecured panels will cause the unit to operate noisily.
- Sharp edges and coil surfaces are potential locations which may cause injury hazards. Avoid from being in contact with these places.
Before turning off the power supply set the remote controller’s ON/OFF
switch to the “OFF” position.
If this is not done, the unit’s fans will start turning automatically when
power resumes, posing a hazard to service personnel or the user.
- Do not operate any heating apparatus too close to the ceiling fan unit or use in room where mineral oil, oil vapour or oil steam exists, this may cause plastic part to melt or deform as a result of excessive heat or chemical reaction.
- Avoid the ceiling fan unit from exposing to direct sunlight, this may cause degradation of plastic material as a result of excessive heat and UV radiation.
- Ensure the colour of wires of the outdoor unit and the terminal markings are same to the indoors respectively.
- Don’t use joined and twisted wires for incoming power supply.
- Do not place any object in the path of the blades. Avoid raising objects or your arms near the ceiling fan.
- The fan suspension system and blade screw tightening shall be examined yearly.
- Replacement of parts of the safety suspension system device shall be performed by the manufacturer, its service agent or suitably qualified persons.
- Torque value for screw/bolts for securing primary suspension system for motor is 2Nm.
Parts & Accessories
Installation Instruction
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
STEP 1
- Remove safety wire screw and washer from Downrod
- Detach Canopy vand Coupling Cover from Downrod.
STEP 2
- Install the Fan Blade on Motor Assembly with screw.
STEP 3
- Reinstall safety wire screw and washer, Canopy and Coupling Cover back to Downrod
- Fix the Rubber Pulley Assembly to the Downrod with Bolt, Washer, Nut and tighten them firmly, then insert the Clevis Pin.
- Remove the Bolt, Clevis Pin, Nut, Washer and Rubber Pulley from the Downrod.
- Place the Rubber Pulley onto the ceiling hook.
- Fix back the Bolt, Clevis Pin, Nut and Washer.
STEP 4
- Remove the Safety Wire screw and washer from the Downrod.
- Install the Safety Cable.
STEP 5
- Connect the LED Light Connector.
- Install LED Light Kit onto Motor Assembly by screw.
STEP 6
- Install Lamp Shade by twisting in.
STEP 7
- Connect the Connectors from the Fan and Receiver.
- Connect the wires from the receiver to House’s Supply Wire.
- Connect Earth Wire to House Supply Earth Terminal.
- Tighten a screw on Canopy and leaving a minimum gap of 5mm between ceiling and Canopy
STEP 8
- Below shows a complete installation diagram.
Power Supply Connection
IMPORTANT : DO NOT CONNECT THIS REMOTE CONTROL CEILING FAN TO DIMMER SWITCH OR REGULATOR.
Circuit Diagram
Transmitter Learning Process
- The receiver & transmitter is pre-programmed in factory. If you wish to control 2 or more Fans using 1 transmitter, the below steps are required.
- DO NOT PRESS ANY OTHER BUTTON DURING THIS PROCESS
Step 1
- A) Insert the 2 pcs of batteries (provided) into transmitter.
- B) Turn on the power supply (wall switch) to the fan.
- C) Within 30 sec., press and hold the “OFF” button for 3 sec. Once the receiver has Detected the frequency, transmitter will “Beep Beep” twice. Programming process is completed and fan is ready to use.
If the fan is not responding to the transmitter, repeat Step 1b.
Transmitter Function
- Light on/off & select LED colour
- Turn off fan
- Fan speed lowest to highest
- Natural wind, creating gentle seabreeze effect
- Forward/Reverse, turn anti-clockwise or clockwise rotation.
- Timer on – fan turns on after 1hr
- Timer on – fan turns on after 3hr
- Timer on – fan turns on after 6hr
The transmitter & receiver is incorporated with last memory function. This function stores your last setting in memory and the next time you turn on the fan, a fan will operate as the last setting.
Function of Forward & Reverse
Fan must be turned on and rotating.
Press Forward/Reverse button and fan will slow down and then change direction
(approx. 15 sec). When the fan is slowing down to change direction, the Fan
Speed function is disabled until direction has been changed.
Forward
Fan rotates anti-clockwise blowing the air downwards creating the wind chill
effect. Suitable for hot weather condition
Reverse
Fan rotates clockwise drawing the air towards the ceiling circulating the warm
air down. awards. This function works best at low speed. Suitable for air-
conditioned condition.
Maintenance
- Due to the fan’s natural movement, connections may get loose after period of usage. To ensure a proper and safety usage, it is highly recommended to inspect and tighten all connections every 6 months.
Cleaning
Cleaning your fan periodically will prolong its new appearance. Basic cleaning
procedures are as follows.
- Use only water and mild soap. Do not use solvents, corrosive or acidic solution.
- Damp the cloth lightly. Use only soft or lint-free cloth to clean the fan. Rough fabric will scratch the surface.
- Do not bent the blades while cleaning. At the event where blades are bent or damage, order new set of blades from service center or dealer shop.
- There is no need to oil the fan.
Technical Specifications
Model | FC-AA02/A | FC-AA04/A | FC-AA06/A | FC-AA07/A |
---|---|---|---|---|
Alt. Name | V3-3B/52 LED | V3-3B/46 LED | V3-3B/40 LED |
V3-3B/28 LED
No. of Blades| 3
Fan Width| 1320mm (52”)| 1165mm (46”)| 1015mm (40”)| 712mm (28”)
Motor RPM| 80 – 233| 90- 265| 82 – 230| 100 – 307
Voltage| 220-240V~ 50Hz
Motor Wattage| 4W – 45W| 4W – 45W| 4W – 45W| 4W – 30W
LED Wattage| 22W
Nett Weight| 5.1kg| 4.9kg| 4.6kg| 4.4kg
Customer Service Centre
If you need any technical assistance or a faulty report, please contact our customer service centre at:
Alpha Home Appliances Sdn. Bhd. (390258-H)
- Head Office : 6, Jalan Sungai Kayu Ara 32/37, Berjaya Park, Section 32, 40460 Shah
- Alam, Selangor.
- Tel : 03-5740 6666 Fax : 03-5740 8220
- Website : www.alphamalaysia.com Email : info@alphamalaysia.com
- Johor : 71, Jalan Molek 3/10, Taman Molek, 81100 Johor Bahru.
- Tel : 07-353 4833 / 4933 Fax : 07-355 4233
- Melaka : 19, 19-1 & 19-2, Jalan KSB 11, Taman Kota Syahbandar, 75200 Melaka.
- Tel: 06-292 6292 / 6293 Fax: 06-292 6296
- Perak : 11, Laluan Tasek Timur 5, Pusat Perdagangan Tasek Indra, 31400 Ipoh, Perak.
- Tel : 05-545 2282 / 547 2282 Fax : 05-547 6282
- Penang : 28, Jalan Icon City, Icon City, 14000 Bukit Mentajam, Penang.
- Tel : 04-506 2366 / 2066 / 2566 Fax : 04-506 2966
- Pahang : A131, TK1, Jalan Wang Ah Jang, Taman Liza, 25100 Kuantan, Pahang.
- Tel : 09-516 5226 Fax : 09-513 9226
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>