The THAR-GM6 is a vehicle immobilizer bypass module designed for Buick Encore and Chevrolet Trax vehicles with push-to-start functionality. It is compatible with models from 2017 to 2021. The module allows for features such as lock/unlock, arm/disarm, trunk control, RAP disable, tachometer, heated seats, door status, trunk status, hand-brake status, foot-brake status, and OEM remote monitoring.
INSTALLATION
THAR-GM6 THARNESS INSTALLATION ADDENDUM – SUGGESTED WIRING CONFIGURATION
INSTALLATION HARNAIS THAR-GM6 ADDENDA – SCHÉMA DE BRANCHEMENT SUGGÉRÉ
Vehicle functions supported in this diagram (functional if equipped) |
VEHICLE VEHICULES
| | USH START
YEARS
|
Immobilizer bypass Nontournament d’immobilisateur
|
Lock
| Unlock| Arm| Disarm| Trunk (open)| RAP Disable| Tachometer| Heated Seats|
Door Status| Trunk Status| Hand-Brake Status| Foot-Brake Status| OEM Remote
Monitoring
BUICK| | | | | | | | | | | | | | | |
Encore| Push-To-Start| 2017-2020| •| •| •| •| •|
•| •| •| •| •| •| •| •| •
CHEVROLET| | | | | | | | | | | | | | | |
Trax| Push-To-Start| 2017-2021| •| •| •| •| •|
•| •| •| •| •| •| •| •| •
BYPASS FIRMWARE VERSION VERSION LOGICIELLE CONTOURNEMENT| To add the
firmware version and the options, use the
FLASH LINK UPDATER or FLASH LINK MOBILE tool,
sold separately. les options, FLASH LINK UPDATER
FLASH LINK MOBILE ,
---|---
70.| [ 45 ]
| MINIMUM
| Program bypass option:| UNIT OPTION OPTION UNITE| DESCRIPTION
---|---|---|---
C1| OEM Remote status (Lock/Unlock) monitoring
IF THE VEHICLE IS NOT EQUIPPED WITH FUNCTIONAL HOOD PIN
D’UN CONTACT DE CAPOT FONCTIONNEL A11 OFF NON Hood trigger (Output Status).
D6
- Push-to-Start
- Push-to-Start
ATTENTION
DATE: XX-XX
- OFF
- NON
- By default DEACTIVATED
- ON MANUFACTURED MODULES
- OUI BETWEEN: 04/2018 TO 04/2019
Parts required (Not included): 1X THAR-GM6
INSTALLATION OBLIGATOIRE
-
HOOD
-
PIN
-
CONTACT
-
HOOD STATUS : THE HOOD PIN SWITCH (INCLUDED) A11
-
MUST BE INSTALLED IF THE VEHICLE CAN BE
-
REMOTE STARTED WITH THE HOOD OPEN, SET FUNCTION A11 TO OFF.
-
STATUT DE CAPOT : LE CONTACT DE CAPOT (INCLUS),
-
SECURITY STICKER
-
AUTOCOLLANT DE
-
Notice: the installation of safety
-
elements are mandatory. The hood pin and the sticker are essential security elements and must be installed.
-
THIS MODULE MUST BE INSTALLED BY A QUALIFIED TECHNICIAN. A WRONG CONNECTION CAN CAUSE PERMANENT DAMAGE TO THE VEHICLE.
DESCRIPTION
- Program remote starter option for R.S. OEM REMOTE STAND ALONE
- Enable
- Press 3x Lock to remote start with the OEM remote.
BCM
AUTOMATIC TRANSMISSION WIRING CONNECTION
KEY BYPASS PROGRAMMING PROCEDURE 1/2
- Remove the battery from the OEM remote.
- Place the OEM remote in the front cup holder in the center console.
Refer to vehicle user guide for Keyport location
Press and hold Insert the programming button:
Insert the 6-Pin Main connector
The LEDs will alternate between BLUE, RED, YELLOW & BLUE/RED flashes
Release the programming button when the LED is YELLOW
If the LED is not solid YELLOW disconnect the 6-Pin connector (Main-Harness)
and go back to step 1.
Insert the required remaining ,connectors
Press and release the programming button five (5x) times.
The YELLOW LED will flash 5 times each second.
WAIT for the YELLOW LED to turn ON solidi.
Open the driver door.
Press the foot-brake pedal.
Press the Push-to-Start button until the engine start.
Release the foot-brake pedal.
Press the Push-to-Start button until the engine turn OFF.
Close and open the driver door.
Press the foot-brake pedal.
Press the Push-to-Start button until the engine start.
Release the foot-brake pedal.
The BLUE LED will turn ON
The BLUE LED will turn OFF.
The RED LED will turn OFF
The YELLOW LED will flash rapidly
The BLUE LED will turn ON.
The BLUE LED will flash rapidly
Press the Push-to-Start
button until the engine turn OFF.
The BLUE LED will flash slowly
Disconnect all connectors
and after the 6-Pin (Main-Harness) or the 4-Pin Data-link connector.
Microsoft Windows Computer with Internet connection
Ordinator Microsoft Windows avec connection Internet
Smartphone (Internet provider
charges may apply)
Use the tool
FLASH LINK UPDATER or
FLASH LINK MOBILE
to visit the Cryptor menu
AFTER DCRYPTOR PROGRAMMING COMPLETED
Go back to the vehicle and reconnect the 6-Pin (Main- Harness) or the 4-pins
(Data-Link) connector and after all the remaining connector.
PROCEDURE
The module is now programmed.
REFER TO THE QUICK INSTALL GUIDE INCLUDED WITH THE
MODULE FOR THE REMOTE STARTER PROGRAMMING
REMOTE STARTER FUNCTIONNALITY
All doors must be closed.
Remote start the vehicle.
Press the Unlock button of the remote car starter
Enter the vehicle with the Intelligent Access Key
The vehicle can now be put in to gear and driven.
If the vehicle is not unlocked the module will shut down the remote-starter
and the vehicle as soon as any door is opened.
Notice: Updated Firmware and Installation Guides
Updated fi rewire and installation guides are posted on our web site on a
regular basis. We recommend that you update this module to the latest fi rewire
and download the latest installation guide(s) prior to the installation of
this product.
WARNING
The information on this sheet is provided on an (as is) basis with no
representation or warranty of accuracy whatsoever. It is the sole
responsibility of the installer to check and verify any circuit before
connecting to it. Only a computer safe logic probe or digital multimeter
should be used. FORTIN ELECTRONIC SYSTEMS assumes absolutely no liability or
responsibility whatsoever pertaining to the accuracy or currency of the
information supplied. The installation in every case is the sole
responsibility of the installer performing the work and FORTIN ELECTRONIC
SYSTEMS assumes no liability or responsibility whatsoever resulting from any
type of installation, whether performed properly, improperly or any other way.
Neither the manufacturer or distributor of this module is responsible of
damages of any kind indirectly or directly caused by this module, except for
the replacement of this module in case of manufacturing defects. This module
must be installed by qualia edh technician. The information supplied is a
guide only. This instruction guide may change without notice. Visit
www.fortinbypass.com to get the latest version.
www.fortinbypass.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>