FORTIN THAR-NIS1 THARNESS Push To Start Infiniti Installation Guide

June 13, 2024
FORTIN

THAR-NIS1 THARNESS Push To Start Infiniti
Installation Guide

FORTIN THAR NIS1 THARNESS Push To Start Infiniti

REV.: 20230704
Guide # 84461
THAR-NIS1 THARNESS INSTALLATION
ADDENDUM – SUGGESTED WIRING CONFIGURATION
VEHICLE YEARS

THAR-NIS1 THARNESS Push To Start Infiniti

Vehicle functions supported in this diagram (functional if equipped)

Immobilizer bypass

T-Harness
Lock
Unlock
Arm
Disarm
RAP Disable
Parking Light
Tachometer
Door Status
Trunk Status
Hood Status*
Hand-Brake Status
Foot-Brake Status
OEM Remote monitoring
Push-to-Start Control

NISSAN Maxima
Push-to-Start (AT)
2009-2014

FIRMWARE VERSION
To add the firmware version and the options, use the FLASH LINK UPDATER or FLASH LINK MOBILE tool, sold separately.

Program bypass option:

UNIT OPTION DESCRIPTION
C1 OEM Remote status (Lock/Unlock) monitoring
D6 Push-to-Start

IF THE VEHICLE IS NOT EQUIPPED WITH FUNCTIONAL HOOD PIN:

A11| OFF
NON| Hood trigger (Output Status).
---|---|---

MANDATORY INSTALL

  • HOOD PIN

HOOD STATUS : THE HOOD PIN SWITCH MUST BE INSTALLED IF THE VEHICLE CAN BE REMOTE STARTED WITH THE HOOD OPEN, SET FUNCTION A11 TO OFF.
A11 OFF NON
Notice: the installation of safety elements are mandatory. The hood pin is an essential security element and must be installed.
THIS MODULE MUST BE INSTALLED BY A QUALIFIED TECHNICIAN. A WRONG CONNECTION CAN CAUSE PERMANENT DAMAGE TO THE VEHICLE.

DESCRIPTION

FORTIN THAR NIS1 THARNESS Push To Start Infiniti -
DESCRIPTIONFORTIN THAR NIS1 THARNESS
Push To Start Infiniti - DESCRIPTION1

FORTIN THAR NIS1 THARNESS Push To Start Infiniti -
DESCRIPTION2

WIRING CONNECTION WITHOUT DATA-LINKFORTIN THAR NIS1 THARNESS Push To
Start Infiniti - DESCRIPTION3

KEY BYPASS PROGRAMMING PROCEDURE 1/2

FORTIN THAR NIS1 THARNESS Push To Start Infiniti -
DESCRIPTION4

Insert the key in to the key port.

Press and hold the programming button:
Connect the 4-PIN Data-link harness (Black connector).
The Blue, Red, Yellow and Blue & Red LEDs will alternatively illuminate.

Release the programming button when the LED is YELLOW.
If the LED is not solid YELLOW disconnect the 4-Pin connector (Main-Harness) and go back to step 1.

Insert the required remaining connectors.

FORTIN THAR NIS1 THARNESS Push To Start Infiniti - Insert
1

Press and release the programming button two (2x) times.
The YELLOW LED will flash 2 times each second.
WAIT for the YELLOW LED to turn ON solidi.

Press and release the Push-to-Start button once (x1).
The RED LED will turns ON
  Wait for the BLUE LED to turn ON.

If the BLUE, YELLOW and RED LED’s are not solid, press and release the PTS button twice to turn OFF the engine and then press and release the PTS button once again to turn the Accessory ON.
Repeat this step until the BLUE, YELLOW and RED LED’s are solid.

KEY BYPASS PROGRAMMING PROCEDURE 2/2

Press and release the Push-to-Start button once (x1) to turn On ignition.
Wait for the BLUE LED to flash rapidly.

Press and release the Push-to­ Start button once to shut off the ignition.

Press and release the Push-to­ Start button twice to turn ON the ignition.
The BLUE, YELLOW and
RED LED’s will rapidly alternate.
The YELLOW LED begins to flash rapidly: Key bypass programme Press and release the Push-to­ Start button once to shut off the ignition.

The module is now programmed. Use the remote of the remote starter or security system to test all of the supported features to ensure proper programming.

REMOTE STARTER FUNCTIONALITY

FORTIN THAR NIS1 THARNESS Push To Start Infiniti - YELLOW
LED4 If the vehicle is not unlocked with one of these conditions the remote-starter will shut down as soon as any door is opened.
FORTIN THAR NIS1 THARNESS Push To Start Infiniti -
icon4

www.fortinbypass.com
Module label

Notice: Updated Firmware and Installation Guides
Updated firmware and installation guides are posted on our web site on a regular basis. We recommend that you update this module to the latest firmware and download the latest installation guide(s) prior to the installation of this product.

WARNING
The information on this sheet is provided on an (as is) basis with no representation or warranty of accuracy whatsoever. It is the sole responsibility of the installer to check and verify any circuit before connecting to it. Only a computer  safe logic probe or digital multimeter should be used. FORTIN ELECTRONIC SYSTEMS assumes absolutely no liability or responsibility whatsoever pertaining to the accuracy or currency of the information supplied. The installation in  every case is the sole responsibility of the installer performing the work and FORTIN ELECTRONIC SYSTEMS assumes no liability or responsibility whatsoever resulting from any type of installation, whether performed properly,  improperly or any other way. Neither the manufacturer or distributor of this module is responsible of damages of any kind indirectly or directly caused by this module, except for the replacement of this module in case of manufacturing  defects. This module must be installed by qualified technician. The information supplied is a guide only. This instruction guide may change without notice. Visit www.fortinbypass.com to get the latest version.

TECH SUPPORT
Tel: 514-255-HELP (4357)
1-877-336-7797
ADDENDUM GUIDE