The SOLAR Power Inverter is available in four different models: PI5000X, PI10000X, PI15000X, and PI20000X. This power inverter is designed to operate from a 12 Volt DC power source only. It contains chemicals, including lead, which are known to the State of California to cause cancer, birth defects, and other reproductive harm. It is important to wash hands after handling the product.

Product Usage Instructions
Before using the SOLAR Power Inverter, it is crucial to read the entire instruction manual. Failure to follow the instructions may cause damage or explosion. Always wear protective eyewear and shield your eyes when using the power inverter. When operating the SOLAR Power Inverter, keep the following things in mind:

  • Always have someone within range of your voice or close enough to come to your aid when working near a lead-acid battery.
  • Keep plenty of fresh water and soap nearby in case battery acid contacts skin, clothing, or eyes.
  • Wear protective eyewear when working near lead-acid batteries.
  • If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters the eye, flood the eye with running cold water for at least 10 minutes and seek medical attention immediately.
  • Be cautious to prevent dropping a metal tool onto the battery as it may spark or short-circuit the battery, potentially causing an explosion. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery to avoid severe burns caused by a short-circuit current.
  • It is important to note that the SOLAR Power Inverter should never be connected to any power source other than a 12 Volt DC power source. Do not operate the power inverter in the vicinity of flammables, such as gasoline, as it can produce arcs or sparks. To prevent fire or explosion, avoid installing or operating the power inverter in compartments containing flammables or batteries, or in locations that require ignition-protected equipment.

Failure to follow instructions may cause damage or explosion, always shield your eyes. Read the entire instruction manual before use.

Warning: This product contains chemicals, including lead, known to the State of California to cause cancer, birth defects, and other reproductive harm. Wash hands after handling.

SOLAR Power Inverter

Congratulations! You have just purchased the finest quality power inverter on the market. We have taken numerous measures in our quality control and in our manufacturing processes to ensure that your product arrives in top condition and that it will perform to your satisfaction. Inverters are designed to convert 12 Volt DC power into household AC power. SOLAR power inverters, with Sonic Compression technology, are designed to provide stable, clean, and reliable power with high surge capacity for use in powering a wide variety of powered tools, appliances, and electronics. Our technologically advanced, microprocessor-controlled power inverters run cooler and more efficiently than competing products. This results in a longer operating time and extended battery life when using SOLAR power inverters. In the rare event that your SOLAR power inverter contains a damaged item, is missing any specific item, or requires warranty service, please call Technical Service at 913-310-1050. Save your purchase receipt, it is required for warranty service.

IMPORTANT SAFETY INSTRUCTIONS – SAVE THESE INSTRUCTIONS!

WARNING
Read these instructions completely before using the SOLAR Power Inverter and save them for future reference. Before using the SOLAR Power Inverter for powering an appliance, read these instructions and the instruction manual/safety information provided by the car, truck, boat, or equipment manufacturer. Following all manufacturers’ instructions and safety procedures will reduce the risk of accidents. Working around lead-acid batteries may be dangerous. Lead-acid batteries release explosive gases
during normal operation, charging, and jump-starting. Carefully read and follow these instructions for safe use. Always follow the specific instructions in this manual and on the SOLAR Power Inverter each time you use the SOLAR Power Inverter. All lead-acid batteries (cars, trucks, and boats) produce hydrogen gas which may violently explode in the presence of fire or sparks. Do not smoke, use matches or a cigarette lighter while near batteries. Do not handle the battery while wearing vinyl clothing because static electricity sparks are generated when vinyl clothing is rubbed. Review all cautionary material on the SOLAR Power Inverter and on all batteries used to power the inverter.

Do not set an AC power cord plug in water or on wet surfaces. Do not attempt to plug in this unit or operate its controls with wet hands or while standing in water. This unit is intended for indoor use only. Never attempt to plug in or operate equipment with defective or damaged wires, power cord or power cord plugs. Have any defective or damaged parts replaced immediately by qualified personnel? Use only properly rated extension cords. Use of an improper extension cord could result in a risk of fire and electric shock. Always wear eye protection, appropriate protective clothing, and other safety equipment when working near lead-acid batteries. Do not touch your eyes while working on or around lead-acid batteries. Always keep power source input cables away from each other or common conductors. Improper use or routing of input cables may cause the cables to come in contact with each other, or a common conductor, which could cause a spark, creating an explosion or fire in the presence of battery gases. Use extreme care while working within an engine compartment, because moving parts may cause severe injury. Read and follow all safety instructions published in the vehicle’s Owner’s Manual. Power source batteries used to power the inverter likely contain liquid acids which are hazardous if spilled.

WARNING : This product contains chemicals, including lead, known to the State of California to cause cancer, birth defects, and other reproductive harm. Wash hands after handling.

Personal Precautions
Someone should always be within range of your voice or close enough to come to your aid when you work near a lead-acid battery. Have plenty of fresh water and soap nearby in case battery acid contacts skin, clothing or eyes. Protective eyewear should always be worn when working near lead-acid batteries. If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately. Be extra cautious to reduce the risk of dropping a metal tool onto the battery. It might spark or short-circuit the battery or other electrical part which may cause an explosion. Remove personal metal items such as rings, bracelets, necklaces and watches when working with a lead-acid battery. A lead-acid battery can produce a short-circuit current high enough to weld a ring or the like to metal causing a severe burn.

Important Safety Instructions

Your power inverter is designed to operate from a 12 Volt DC power source only. NEVER attempt to connect your SOLAR power inverter to any other power source, including any AC power source. Do not operate the SOLAR power inverter in the vicinity of flammables, such as gasoline, etc. This equipment can produce arcs or sparks. To prevent fire or explosion, do not install or operate the power inverter in compartments containing flammables or batteries, or in any location that requires ignition-protected equipment. Do not operate the power inverter if you, the inverter, the device being powered or any other surfaces that may come into contact with the 12 Volt power source are wet. Do not expose your power inverter to rain, snow, spray or bilge water.

Keep your SOLAR power inverter well-ventilated when in operation. When in use, maintain several inches of clearance around the top and sides of the power inverter. Avoid placing the power inverter near sources of heat, such as heat vents and radiators, or in direct sunlight. Loose connections can result in a severe decrease in voltage, and may cause damage to the wires and insulation in the power inverter. Always check that all connections are correct and secure prior to powering the inverter or any device connected to it. Always ensure that all wiring is in good condition and of the proper size – operating the power inverter with damaged or substandard wire could create a risk of fire or electric shock. Do not operate your power inverter if it has received a sharp blow, been dropped, or is similarly damaged until after being inspected and/or repaired by qualified service personnel. When connecting device/appliance power cords to the inverter, pull on the plug and never on the wire when disconnecting. Do not operate a device/appliance with a damaged power cord.

NEVER connect your SOLAR power inverter to a frozen battery. While some of our smaller units are designed to plug into a 12 Volt vehicle outlet, larger models, including those covered in this manual, must be properly connected to a battery. Extreme care must be taken to follow all applicable codes when working with electricity. To avoid battery drain, always disconnect your SOLAR power inverter when not in use. Precautions When Using the Power Inverter to Power Rechargeable Appliances Many rechargeable appliances and equipment utilize a separate charging system for recharging that is connected to an AC outlet. Such charging systems typically produce a low voltage output for recharging the appliance or equipment. Some such charging systems used to charge small batteries can be damaged if powered by your SOLAR power inverter. We suggest not using your SOLAR power inverter to charge:

  • Power tool battery pack charging systems, such as those found in battery-powered drills, saws, etc.
  • Small battery charging systems such as those found in razors, flashlights, and night lights, are typically plugged directly into an AC outlet, without the use of an external transformer.

How Power Inverters Work

Power inverters utilize a two-step method to convert 12 Volt direct current (DC) power into 115 Volt AC power. In the first step, the power inverter uses a DC-to-DC converter to increase the DC voltage from the original 12 Volts DC to 145 Volts DC. In the second step, the power inverter converts high-voltage DC power into 115 Volt AC power using advanced micro-circuitry which we refer to as Sonic Compression technology. It is this Sonic Compression technology that enables SOLAR power inverters to accommodate strenuous “peak power” and “continuous power” demands, while at the same time, providing the assurance of automatic overload protection.

The modified sine wave produced using our Sonic Compression technology has a root mean square (RMS) voltage of 115 Volts. Most AC voltmeters are calibrated to measure the RMS voltage of a pure sine wave. For this reason, most voltmeters will not measure the output voltage of your power inverter correctly, typically showing an output about 20-30 Volts below the actual output. To accurately measure the output voltage of your SOLAR power inverter, use only a voltmeter identified as a “True RMS” reading voltmeter. Things to remember when operating your SOLAR power inverter: Loose connections can result in a severe decrease in voltage and may cause damage to the wires and insulation in the power inverter. Always check that all connections are correct and secure prior to powering the inverter and any device connected to it.

Failure to make a proper connection between the power inverter and the 12 Volt power source can result in a reverse polarity condition. A reverse polarity condition will blow the internal fuse(s) of the inverter and may cause permanent damage to the inverter. Damage caused by a reverse polarity condition is not covered in the warranty. When making the connection between the Positive terminals of the power inverter and the 12 Volt power source, it is possible that you may create a spark. For this reason, it is critical that both the power inverter and the 12 Volt power source not be positioned in the vicinity of flammable fumes or gases. When attempting to power any device using your inverter, monitor the temperature of the device for approximately
10 minutes. If the device being powered becomes abnormally warm, disconnect it from the power inverter immediately.

When using an automobile or marine battery to power the inverter, start the vehicle’s engine every 30 to 60 minutes and let it run for approximately 10 minutes to recharge the vehicle’s battery. We recommend that the device being powered by the inverter, as well as the inverter itself, be turned OFF before starting the vehicle’s engine. When your power inverter is not in use and turned OFF, it draws a very low amperage from the 12 Volt power source when connected. As a result, we recommend that you disconnect the power inverter from the 12 Volt power source when not in use. The use of an extension cord between the SOLAR power inverter and the device being powered will not significantly decrease the power generated by the power inverter. For best results, do not use an extension cord longer than 50 ft.

SOLAR Power Inverter Safety Features
Your SOLAR power inverter is equipped with automatic shut-off protection which will be activated if any of several unsafe operating conditions exist. In the event that any of the following conditions occur, the Fault Indicator light will turn on and the power inverter will shut down:

  1. The power input from the 12 Volt power source drops to 10.0 Volts. (When the power from the 12 Volt power source drops to 10.5 Volts, an extended audible alarm will sound, warning you that your power source is low.)
  2. The power input from the 12 Volt power source exceeds 15.0 Volts.
  3. The “continuous power” demand from powered devices exceeds the power rating of your inverter.
  4. The “peak power” demand from the powered device exceeds the peak power rating of your power inverter.
  5. The circuit temperature within the power inverter exceeds 149˚F (65ºC). In the event, the automatic shutdown protection occurs or the inverter sounds a continuous audible alarm, turn OFF the power inverter immediately. Do not restart the power inverter until the source of the problem has been identified and corrected.

Installation

Things to Remember When Planning Your Installation Please read this section on power inverter installation in its entirety before beginning the installation process. There are many things to consider that will have a bearing on both the safety and performance of your power inverter and power delivery system. While your power inverter is specified and advertised to deliver a range of continuous power to an upper limit threshold, all aspects of your power system must support the inverter reaching full power. The decisions you make about your power delivery system components and design will directly impact your ability to get the most out of your power inverter, both in the short and long term. It is important that you consider your specific application and design your power inverter system to meet the needs of your application. It is also important that you ensure that you are in compliance with all local, state and national codes governing your installation (See Installation Code Compliance). Throughout this section, you may want to refer to the Power Inverter Installation Schematic on page 11 for an example of a typical installation.

Installation Code Compliance
Your power inverter is a serious piece of equipment and should be used only by those competent to install and operate it. In certain applications, installation and operation will be governed by local, state or national codes. These codes will vary based on your locale and on your particular installation location and application. It is your responsibility to ensure that you are compliant with all such codes. Failure to follow these codes may result in personal injury or property damage.

Battery Types, Sizes, and Inverter Power Requirements
Note: Your power inverter is designed to be connected to a 12 Volt Power Source (12 Volt battery or batteries). Do not connect your power inverter to either a 6 Volt battery or a 24 Volt battery configuration. Doing so will damage the power inverter and could cause personal injury or property damage!

Clore-Automotive-PI10000X-Solar-Power-Inverter-fig-1

Choosing the Right Battery Type
One of the most important determinants of the success of your installation is your choice of DC power source. What types of batteries should be used? How large should they be? How many are needed? Your choice of battery type and total battery capacity can have a serious impact on your system performance and ability to successfully and repeatedly perform the desired applications. The most common battery type is the standard, or conventional, flooded acid starting battery, which is used in most of today’s passenger vehicles. While this type of battery could be successfully used in certain power inverter systems, it is not the recommended battery for this application. This is because most power inverter system applications will cause the battery(ies) used to undergo deep discharge/recharge cycles in the course of normal operation. Standard flooded acid starting batteries do not last long under such use, as they are typically designed to deliver a very fast “starting” burst of power (which does not result in a deep discharge) to start a vehicle and are then immediately recharged by the vehicle’s charging system.

The preferred battery type for a power inverter system application is a cycling battery, sometimes referred to as a deep cycle battery, marine battery or RV battery. Cycling batteries are designed to be used in deep discharge/ recharge cycling applications without affecting their longevity or performance. Please note that, when you are using more than one battery to meet your power source needs to power the inverter (see Determining Battery Capacity Needs), you should take care to ensure that all of the batteries used are matching in terms of manufacturer, battery type, capacity, state of charge, etc. This ensures the system will perform in a stable manner and that recharging will distribute the charge equally among the batteries being used. In situations where multiple batteries are connected in series, parallel or series/parallel, replacement batteries should be the same size, type, and manufacturer (if possible). Age and usage level should be the same as the companion batteries. Do not put a new battery in a group that is more than 3 months old or has more than 75 cycles. Either replace with all new or use a good used battery.

Determining Your Battery Capacity Needs
Another very important determinant of the success of your installation is the battery capacity allocated to your power inverter system. It is only by providing the necessary 12 Volt input power that you can achieve the maximum rated output of the power inverter. There are many different ratings used to value the energy stored in a battery. Most starting batteries rate their power using “Cranking Amps” or “Cold Cranking Amps”. While these ratings are a very good way to determine a battery’s viability in a specific starting application, they are of little use when determining if a specific battery is suitable for a power inverter system application. Deep Cycle batteries are usually rated in either Reserve Capacity (expressed in minutes) or Amp Hours. Both of these measures provide a rating of how long the battery can provide power, either expressed as how long a battery can provide a certain power output (Reserve Capacity Minutes) or how much power can be delivered over a certain timespan (Amp Hours).

To determine your power requirement, and therefore your battery capacity requirement, you will need to combine the power needs of all of your typical daily applications or uses, of the power inverter system. First, determine the wattage requirement of each tool, electronic item or appliance that you will use, which is usually listed on the item. To determine the power draw in watts of an item that is listed only in amps, multiply the amp draw times 120. Then, for each item, determine the length of time each item will be powered. Multiply the wattage requirement times the hours for each item, which yields the watt-hours required for each. Add the watt-hours for all items to get a total watt-hour requirement. Then, multiply the total watt-hour requirement (for all items) times the number of days between charging your battery(ies). (Note: This step is unnecessary if you plan to recharge your battery(ies) nightly.) Divide your total watt-hour days by 10 to derive your amp-hour requirement.

Here is an example of the calculation that you might perform: Item to be Powered Draw Expected Run Time Watt-Hour Requirement

  • Computer 180 Watts 4 hours 720
  • 3/8” Drill 840 Watts 1 hour 840
  • Recip Saw 1440 Watts .5 hours 720
  • Shop Vac 960 Watts 1 hour 960
  • Total Watt-Hour Requirement: 3240

Battery Amp Hour Requirement (total Watt-Hours Divided by 10): 325
Note: If a battery you are considering is rated in Reserve Capacity, use the following formula to convert reserve capacity to amp hours: (Reserve Capacity/2) + 15.5 = Amp-Hour Rating We recommend that you create an installation with a total capacity at 1.75-2.5 times your derived amp-hour requirement. This will allow you to perform unanticipated applications or delay your normal charging cycle without detriment to the system (by over- discharging the system’s batteries) or your planned applications. In the above example, you should plan to provide between 700 and 1100 total Amp Hours in battery capacity, depending on the variability of your application needs or the sureness of your recharging schedule. Batteries Connected to a Vehicle System We recommend that, when using batteries that are connected to a vehicle’s charging system, you use auxiliary batteries to supply power to your inverter, rather than the vehicle’s starting battery. In addition, we recommend that you utilize a battery isolator in order to avoid draining your vehicle’s starting battery while powering your inverter. A battery isolator allows you to recharge your auxiliary power batteries from the vehicle’s charging system while protecting the vehicle’s starting battery. Battery isolators can be found at most auto parts stores. Please see Charging System Requirements for more details.

Charging System Requirements

Just as it is important to use the right type of battery and have adequate battery capacity for your application, it is also important that you utilize a charging system appropriate for your situation. Having an inadequate charging system could result in undercharging your power supply battery(ies), which could drastically reduce their lifespan. It could also result in inadequate power capacity in the battery(ies) when you need them to perform a specific application. For these reasons, it is critical that the charging system chosen is properly matched to the power inverter and battery(ies) used. Throughout this manual, we refer to your complete installation as your power inverter system and it is important that all components in the system are matched to provide optimal performance. Charging Batteries Using a Vehicle Charging System Your charging system must sufficiently charge your battery(ies) such that enough charging current is delivered to avoid draining the power source battery(ies) while the power inverter is in use. Most standard vehicle alternators do not output enough current to maintain large batteries when used as an inverter power source. In this type of installation, a high current alternator is preferred, as it is more likely to be able to provide the necessary power. It is important that you calculate your specific alternator output requirement prior to purchasing a high-current alternator for this purpose to be sure that the product you purchase meets your needs. High- current alternators can be found at most auto parts stores.

Charging Batteries Independent of a Vehicle Charging System
Like charging from a vehicle system, it is important that you consider your specific application and needs when designing your charging system. Consider all factors involved, including the total battery capacity that will need to be charged, the amount of time that you have to charge the battery(ies), and the best way to deliver the charge. The key to a successful charging system is that your battery(ies) are fully charged and ready for service when you need them next.

Testing Batteries to Ensure Readiness
It is good practice to periodically check the condition of your battery(ies) when discharged and at the completion of the charging process to ensure that your charging system is functioning properly and keeping your battery(ies) in good health. To do so, we recommend using an electronic battery tester. Follow all procedures outlined by the battery tester manufacturer and those from the battery manufacturer. If your battery(ies) are of the Conventional Flooded Acid type (not Maintenance-Free), it is important to check the electrolyte level regularly and ensure that the proper level is maintained. Use only distilled water when replenishing the electrolyte. Follow all procedures outlined by the battery manufacturer when replenishing the electrolyte.

Cable Requirements
Warning: Failure to use proper DC input cables (size, length, and composition) could result in excessive heat generation, possibly resulting in poor system performance, damage to equipment, fire, and personal injury! Note: We recommend consulting a qualified electrician and reviewing the National Electrical Codes when determining the best method of connecting your power source battery(ies) to your power inverter. DC Input and Grounding Cable Requirements As with all other power inverter system components, it is critical that your DC input cables (positive and negative) be properly matched to ensure peak performance and safe operation. Because your 12 Volt power source will generate extremely high current, it is important that you use high-quality, low-resistance stranded copper cable. In addition, always permanently connect cables using properly rated connections and make sure that the cable connections are tight. Your DC input cables should be as short as possible, yet still allowing the inverter to be placed in a separate compartment from the power source battery(ies) (see Choosing an Installation Location). We recommend NEVER exceeding 5 ft. in length (one side) and following the table below for DC Input Cable Size.

  • Model No. Cable Gauge Preferred Length Max Length
  • PI5000X #2 AWG 3’ 5’
  • PI10000X #2 AWG 3’ 5’
  • PI15000X 2/0 3’ 5’
  • PI20000X 4/0 3’ 5’

The greater your DC input cable length, the greater your power loss will be between the power supply battery(ies) and the power inverter. Exceeding recommended cable lengths could result in poor power inverter performance and an inability to meet the rated output of the power inverter. Your DC input cables should be weather rated to stand up to your local conditions and oil- resistant to provide safe operation over time. Because cables are often passed through sheet metal, firewalls and other areas potentially having rough edges, it is very important that all wires be protected from chaffing.

Chassis Grounding Cable Requirements
For certain applications, you are required to properly ground the inverter chassis. Your power inverter has a ground screw for grounding the power inverter chassis. On Model PI10000X, the ground screw is located at the bottom right of the DC Input Panel. On Model Nos. PI15000X and PI20000X, the ground screw is located on the bottom panel and is marked by a ground label. We recommend using a 14 gauge insulated ground wire. Just as with DC input cables, the chassis ground wire should be a short as possible, preferably not exceeding 10 feet. Always be sure that you are connecting to the proper ground. For vehicle installations, you should never connect to sheet metal, fuel lines, fuel injector, carburetor or a moving part as a grounding device – for this purpose, the best grounding points are the engine block or vehicle frame. Always ensure that cables are not in the path of moving engine parts.

Fuse/Circuit Breaker Requirements
Because the short circuit current from your 12-volt power source can be extremely high, it is important to install a fuse or circuit breaker between your power source battery(ies) and the power inverter. Each power inverter identifies its maximum power drawn from the DC power source battery(ies) on the DC input panel. Choose a fuse or circuit breaker rated at 125%-150% above the maximum DC power drawn from the power inverter. The fuse or circuit breaker should always be installed on the positive lead.

Choosing an Installation Location
Warning: Working around lead-acid batteries may be dangerous. Lead-acid batteries release explosive gases during normal operation, charging and jump- starting. Carefully read and follow these instructions for safe use. Always follow the specific instructions in this manual and on the SOLAR power inverter each time you use the SOLAR power inverter. All lead-acid batteries (car, trucks and boats) produce hydrogen gas which may violently explode in the presence of fire or sparks. Do not smoke, use matches or a cigarette lighter while near batteries. Do not handle the battery while wearing vinyl clothing because static electricity sparks are generated when vinyl clothing is rubbed. Review all cautionary material provided with your batter(ies) and on the SOLAR power inverter.

The power inverter must be installed in a location that is dry and free from exposure to rain, snow, spray or condensation. It should be installed in a location that has an ambient temperature during operation between –5˚C and 40˚C (23˚F and 104˚F) and an ambient temperature during storage between –15˚C and 50˚C (-5˚F and 122˚F). Because engine compartments reach temperatures exceeding both the operating and storage temperature range of the power inverter, it should not be installed in an engine compartment. The power inverter should not be located in the same compartment with your power source battery(ies) nor should it be located near flammable liquids or gases of any kind. The power inverter is capable of producing arcs or sparks. To prevent fire or explosion, do not install or operate the power inverter in compartments containing flammables or batteries, or in any location that requires ignition-protected equipment. The inverter should have several inches (3”-5”) of space around all sides and the top for air circulation, with particular care not to obstruct the vents found on the bottom and ends of the inverter. In addition, do not mount the inverter such that it could become exposed to gases produced by batteries, as these gases are corrosive and could damage the power inverter.

Installing Your Power Inverter
Before installing your power inverter, review the warning section at the beginning of this manual and this Installation section in its entirety. As previously noted, the power inverter should be installed and operated only by those competent to install and operate it. (Refer to the Power Inverter Installation Schematic on page 11 for an example of a typical installation.

Mount the Power Inverter
Do not mount the power inverter in the engine compartment (under the hood) of a vehicle (see Choosing an Installation Location). Make sure that the power inverter is in the OFF position during the installation process. The power inverter can be mounted in one of three orientations:  horizontally on a vertical surface, such that the ends are parallel (fan not facing up or down); on top of a horizontal surface; 3.) underneath a horizontal surface. Care must be taken during the mounting process not to damage the power inverter in any way.

Connect the Chassis Ground
See Chassis Grounding Cable Requirements for details regarding ground cable requirements and connecting to vehicle grounding points. For certain applications, you are required to properly ground the inverter chassis. Your power inverter has a ground screw for grounding the power inverter chassis. On model PI10000X, the ground screw is located at the bottom right of the DC Input Panel. On Model Nos. PI15000X and PI20000X, the ground screw is located on the bottom panel and is marked by a ground label. When installing the ground connection to the power inverter, the power inverter should be turned OFF. For the ground connection, permanently connect cables using properly rated connections and make sure that the cable connections are tight.

Connect the DC Input Cables
See DC Input Cable Requirements for details regarding DC input cable requirements. Because the short circuit current from your 12-volt power source battery(ies) can be extremely high, it is important to install a fuse or circuit breaker between your power source battery(ies) and the power inverter (See Fuse/Circuit Breaker Requirements). In preparation for making the DC connection, cut DC Input Cables to the appropriate length. Permanently connect cables using properly rated connections and make sure that the cable connections are tight. The connection the sequence should be as follows:
Note: Take extra care to ensure that the polarities are properly matched throughout the connection process. Positive always connects to positive, negative always to negative. Reversing the connection could result in personal injury or property damage.

  • Install the fuse/circuit breaker to the power inverter DC terminals (See Fuse/Circuit Breaker Requirements), making sure the disconnect switch or circuit breaker is turned off prior to installing
  • Make the positive (POS, +) battery connection to the fuse/circuit breaker, starting at the battery
  • Make the negative (NEG, -) battery connection to the power inverter, starting at the power inverter
  • We recommend coating battery connections in fixed applications with Dielectric Grease to maintain a good electrical connection and prevent corrosion on terminals.
  • Recheck the polarity of all cables to ensure that the correct connections have been made
  • Turn on the disconnect switch or circuit breaker
  • Turn the power inverter ON. Set the display to show Input Voltage. The display should provide a detailed reading of your power source battery(ies) voltage
  • If the power inverter does not turn ON or does not display input voltage, check your battery condition and all connections and repeat.

Connect the AC Cables
Before connecting any device to be powered by the power inverter to an AC receptacle on the power inverter, ensure that both the device and the power inverter are turned OFF. Plug the device into the power inverter’s AC receptacle. If you run the AC cable of any device through a wall or other barrier or near any sharp or rough edges, always be sure to protect the AC cable from chaffing. When disconnecting any device powered by the power inverter, always pull on the plug and never on the wire. NEVER operate a device with a damaged power cord. Power Inverter Installation Schematic

Operation

Your power inverter has been designed to provide reliable service, ease of use, and safe operation. Please read this section in its entirety, as well as the entire Installation section, prior to operating your power inverter. Your power inverter is designed for use in a wide variety of vehicle-installed and independent applications. Key aspects of your power inverter’s operation include:

  • The power inverter provides continuous operating power of 500W (PI5000X), 1000W (PI10000X), 1500W (PI15000X) or 2000W (PI20000X) to operate a wide variety of powered tools, appliances, and electronics.
  • The power inverter provides a peak power capability of twice the continuous power rating to meet the initial surge demand of tools and appliances during start-up.
  • The power inverter features a convenient display (PI15000X and PI20000X only) that provides detailed information regarding the voltage of the power source battery(ies) and the output wattage drawn from connected appliances and equipment.
  • The power inverter places only a small load on the power source battery(ies) when the inverter is powered but not in use. Despite this, eventually, even a minor load such as this will drain your power source battery(ies). For this reason, when possible, turn the power inverter OFF when not in use.
  • The power inverter utilizes a fan for cooling purposes, which turns ON only when a specific temperature is reached and then turns OFF when the unit has cooled down. This limits the power draw of the power inverter both when idle and during operation.
  • The power inverter incorporates a wide variety of features designed to ensure safe operation and to protect the power source battery(ies) from damage due to excessively deep cycling.

Connecting and Powering AC Equipment
Always ensure that both the power inverter and the equipment to be powered are OFF when connecting the equipment to the power inverter. Always remember to pull on the plug and never on the wire when disconnecting equipment from the power inverter. Once the equipment to be powered has been properly connected to the power inverter (and is in the OFF position), turn the power inverter ON by switching the ON/OFF switch on the output panel to the ON position. Then, turn on the equipment to be powered. Once the application is completed, turn the power OFF on the equipment being powered and then turn OFF the power inverter by switching the ON/OFF switch on the output panel to the OFF position. When powering more than one piece of equipment with the power inverter, turn each piece of equipment ON in succession and not at the same time. This avoids the increased peak power demand that would be caused by
turning multiple pieces of equipment ON at the same time. This will help prevent overloads and unnecessary
shutdowns.

Managing Your Power Demand
Your power inverter has several elements on the output panel to assist you in managing your power demand and the operation of the inverter. A Power LED indicates that the inverter is powered when the unit is turned ON and is properly connected to a 12 Volt power source. A Fault LED indicates if a fault condition exists that is resulting in the shutdown of the unit to protect the power inverter, the power source battery(ies), powered equipment or the operator. In addition, some models (PI15000X and PI20000X) feature a power display that shows both the voltage condition of your power source battery(ies) and the output wattage demand of any powered equipment. This display is very helpful in managing your power demands.

To display the input voltage from your power source batteries, set the display switch to VOLTS. The display will show the DC voltage at the input terminals of the power inverter. This value can, and most often will, be different from the DC voltage at the battery, due to the voltage drop over the length of the DC input cables. The input voltage information provided in this display mode is very useful in determining the charge status of your power source battery(ies) and the amount of time remaining to power connected equipment prior to reaching a low voltage shut down condition.

To display the output wattage demand from all equipment connected to the power inverter, set the display switch to WATTS. The output wattage draws information provided in this display mode is very useful in determining if an additional piece of equipment can be powered by the inverter without exceeding the rated output of the inverter. Assessing the Capacity of Your Power Inverter to Power a Specific Device When you first switch on a powered tool or appliance that utilizes a motor, that device requires an initial surge of power. This initial surge of power required to start the device is referred to as the “peak power”. After initial start-up, the device then requires less power to operate, which is referred to as its “continuous power”. It is important that you determine both the “peak power” and “continuous power” demands of any device you plan to operate using your power inverter. The power demands of any particular device are usually stamped or printed on the device and are usually expressed in either Wattage (Watts) or Amperes (Amps). If this information is not indicated or the device, reference that device’s owner’s manual or contact the manufacturer to ensure that it is compatible with a modified sine wave power source. To determine the power needs of a particular device, use the following formulas: Amps Indicated x 110 (AC Voltage) = Watts (This Wattage amount is roughly equivalent to the “continuous power” demand Watts x 2 = “Peak Power”

(This is roughly equivalent to the initial “peak power” demand of the device at start-up) In most cases, the “peak power” demand of the device is the determining factor in whether your power inverter has the capacity to power that device. To determine whether your inverter has the capacity to power a specific device, test that device using your power inverter. Your SOLAR power inverter is designed to automatically shut down in the event of a power overload. This feature protects the inverter in the event that you attempt to power a device with a power demand exceeding the inverter’s capacity. In the event, the automatic shutdown protection occurs or the inverter sounds a continuous audible alarm, turn off the power inverter immediately. Do not restart the power inverter until the source of the problem has been identified and corrected.

Powering High Surge Loads
Some types of equipment that utilize an induction motor require extremely high peak power to meet the initial surge demand of that motor. In some cases, this equipment cannot be powered by the inverter even though the power requirement of that equipment falls within the operating range of the power inverter. If a specific piece of equipment that utilizes an induction motor is unable to be started when connected to the power inverter, set the power display to Voltage Mode and observe the input voltage to the power inverter while trying to start the equipment. If the voltage indicator nears or goes below 10.5 Volts, this explains why the equipment is failing to start. Check the state of charge of your power source battery(ies) and all connections to ensure power is being properly delivered to the inverter. If such a check does not reveal any problems, you may need to upgrade to a larger battery or group of batteries.

Suggestions When Using Your SOLAR Power Inverter to Power Television and Audio Devices: Although your SOLAR power inverter is shielded and filtered to minimize signal interference, some interference with your television and audio equipment may be unavoidable, particularly when they have weak signals. Here are a few
suggestions to improve your reception under these circumstances:

  1. Make sure the television/audio antenna on the device produces a clear signal under normal operating conditions (when plugged into a standard 110 Volt AC outlet). Also, ensure that the antenna is properly shielded and of good quality.
  2. Change the positions of the power inverter, antenna, and tv/audio power cord to see if a change in their relative positions improves your reception.
  3. Isolate the television/audio device, its power cord, and antenna cables from the power inverter and 12 Volt power source by running an extension cord from the television/audio device power cord to the inverter.
  4. Coil the television power cord and the power cables running from the 12 Volt power source to the power inverter.
  5. Attach a “Ferrite Data Line Filter”, available at most electronic supply stores, to the television/audio device power cord. More than one filter may be required.

Maintenance

Maintenance and Care
A minimum amount of care can keep your power inverter working and looking good for years:

  • Check your battery and DC input connections regularly to ensure that they are tight and free of corrosion.
  • Wipe off any battery fluid at the battery connection. Battery fluid may be neutralized with a solution of water and baking soda.
  • Ensure that the inverter has several inches of space around all sides and the top for air circulation.
  • Ensure that any cables (DC or AC) that are routed through partitions or other obstructions are free from abrasion.
  • If needed, wipe the case clean with a soft cloth.

Replacing Blown Fuses
Your SOLAR power inverter is equipped with fuses of specific amperage ratings and physical design. In most cases, the fuses should not need to be replaced. If replacement is necessary, it is important that you purchase and install the correct replacement fuse(s). Please reference the chart below to determine the correct fuse(s) for your product. Model No. No. of Fuses Fuse Rating Fuse Type

  • PI5000X 2 30 Amp Mini Blade
  • PI10000X 4 30 Amp Mini Blade
  • PI15000X 6 30 Amp Mini Blade
  • PI20000X 8 30 Amp Mini Blade

ALWAYS disconnect your SOLAR power inverter from the 12 Volt power source and disconnect any equipment powered prior to opening the inverter cabinet and attempting to replace the fuse(s). ALWAYS use the proper replacement fuse(s) as indicated in the chart above. Make sure to address the root source of the overload that caused the blown fuse prior to using your power inverter again.

Replacement Parts and Accessories

  • Part No. Description
  • 248-040-666 Connection cables for 1000 W inverter, Model Nos. PI5000X and PI10000X (5ft, #2 AWG)
  • 248-053-666 Connection cables for 1500 W inverter, Model No. PI15000X (5ft, 2/0)
  • 248-054-666 Connection cables for 2000 W inverter, Model No. PI20000X (5ft, 4/0)

Troubleshooting

  • Problem: Low or no output voltage from the power inverter
  • Answer: Check connections between the 12 Volt power source and the power inverter as detailed in “Connect the DC Input Cables.”
  • Answer: Check that the power inverter is turned ON and that the device to be powered is turned ON.
  • Answer: Check the polarity of the DC connection to ensure it is correct. If a reverse connection has been made, most likely the inverter fuses have been blown. Replace fuses. Damage to the inverter caused by a reverse polarity condition is not covered under the warranty.
  • Answer: Using the incorrect type of voltmeter to test the output voltage. To accurately measure the output voltage of your SOLAR Power Inverter, use only a voltmeter identified as a “True
  • RMS” reading voltmeter.
  • Problem: Fault LED ON
  • Answer: The voltage of the 12 Volt power source may have dropped below 10 Volts – check 12 Volt power
  • source voltage and recharge as needed.
  • Answer: The device being powered is placing a power demand on the inverter that is beyond its operating capacity – use a higher capacity power inverter or cease powering that device using your power inverter.
  • Answer: The inverter is too hot – allow the inverter to cool. Check for adequate ventilation. If the problem persists, reduce the load on the power inverter to the rated continuous power.
  • Problem: Low Battery Alarm on Continuously
  • Answer: The voltage of the 12 Volt power source may have dropped below 10.5 Volts – check 12 Volt power source voltage and recharge as needed.
  • Answer: Poor or weak 12 Volt power source – recharge or replace the battery.
  • Answer: Inadequate power delivery from the 12 Volt power source – check the connections between the 12 Volt power source and the power inverter (see “Connect the DC Input Cables”).
  • Problem: Poor Television/Audio Device Reception
  • Answer: Refer to the “Suggestions When Using Your Power Inverter to Power Television and Audio Devices” section within this Operator’s Manual.

Specifications

  • Model No. PI5000X PI10000X PI15000X PI20000X
  • Electrical Specifications
  • Nominal DC Input 12VDC 12VDC 12VDC 12VDC
  • Input Voltage Range 10 – 15VDC 10 – 15VDC 10 – 15VDC 10 – 15VDC
  • Low Voltage Alarm (10.5V) YES YES YES YES
  • Low Voltage Shut-Down (10V) YES YES YES YES
  • Over Voltage Shut-Down (15V) YES YES YES YES
  • Over Heat Protection (149˚F) YES YES YES YES
  • Cooling Fan YES YES YES YES
  • Overload Protection YES YES YES YES
  • Short Circuit Protection YES YES YES YES
  • No Load Current Draw <0.5 A <0.4 A <0.8 A <0.8 A
  • DC Fuse 2 x 30A 4 x 30A 6 x 30A 8 x 30A
  • AC Output Voltage 115VAC (RMS) +/-10% 115VAC (RMS) +/-10% 115VAC (RMS) +/-10% 115VAC (RMS) +/-10%
  • AC Output Frequency 60 Hz +/-3 Hz 60 Hz +/-3 Hz 60 Hz +/-3 60 Hz +/-3
  • Output Waveform Modified sine wave Modified sine wave
  • Maximum continuous AC Power 500W 1000W 1500W 2000W
  • Maximum peak AC Power 1000W 2000W 3000W 4000W
  • Peak Capacity (Seconds) 1 1 1 1
  • Efficiency >86% >86% >85% >85%
  • Operating Temp. Range 23˚-104°F (-5°-40°C) 23˚-104°F (-5°-40°C) 23˚-104°F (-5°-40°C) 23˚-104°F (-5°-40°C)
  • LED Indicators Power, Fault Power, Fault Power, Fault Power, Fault
  • Power Display No No Yes Yes
  • AC Receptacle Dual Dual Triple Triple
  • USB Outlet Yes No No No
  • DC Connection Hardwire or 12V Socket Hardwire Hardwire Hardwire
  • Dimensions (H x W x L) 8” x 4.75” x 2” 10.6” x 5.7” x 3” 14.6” x 8.7” x 3.2” 14.6” x 8.7” x 3.2”
  • Weight 1.925 lbs. (0.87 kg) 4.08 lbs. (1.85 kg) 8.12 lbs. (3.7 kg) 9.92 lbs. (4.5 kg)
  • Warranty One year limited One year limited One year limited One year limited

Warranty

Clore Automotive warrants this product to be free from defects in material or workmanship for a period of one year from the date of the original end-user purchase. This warranty extends to each person who acquires lawful ownership within one year of the original retail purchase but is void if the product has been abused, altered, misused or improperly packaged and damaged when returned for repair. This warranty applies to the product only and does not apply to any accessory items included with the product which are subject to wear from usage; the replacement or repair of these items shall be at the expense of the owner.

THE TERMS OF THE CLORE AUTOMOTIVE LIMITED WARRANTY CONSTITUTE THE BUYER’S SOLE AND EXCLUSIVE REMEDY. THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THIS EXPRESS WARRANTY. AFTER 1 YEAR FROM THE DATE OF PURCHASE, ALL RISK OF LOSS FROM WHATEVER REASON SHALL BE PUT UPON THE PURCHASER. CLORE AUTOMOTIVE SHALL NOT BE LIABLE FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES UNDER ANY CIRCUMSTANCES: CLORE AUTOMOTIVE’S LIABILITY, IF ANY, SHALL NEVER EXCEED THE PURCHASE PRICE OF THIS MACHINE REGARDLESS OF WHETHER LIABILITY IS PREDICATED UPON BREACH OF WARRANTY (EXPRESS OR IMPLIED), NEGLIGENCE, STRICT TORT, OR ANY OTHER THEORY.

Some states do not permit the limitation of warranties or the limitation of consequential or incidental damages, so the above disclaimer and limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Instructions for obtaining service under this warranty: To obtain service under this warranty, return your SOLAR Power Inverter to the place of purchase, along with your dated sales receipt, for an exchange. Your product can also be sent back to Clore Automotive at the address below. Registering Your Purchase For the best service and to receive periodic product updates, follow the instructions below to register your purchase: Please visit: www.cloreregistration.com Click on the SOLAR logo Complete the information in the web form and click “Submit” It’s that easy! For answers to questions concerning use, out-of-warranty service, or warranty/service information on this or other Clore Automotive products, contact: Clore Automotive Technical Service 8600 NE Underground Drive Pillar 248
Kansas City, MO 64161 800.328.2921 913.310.1050
www.cloreautomotive.com
www.solaronline.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Clore Automotive User Manuals

Related Manuals